| Literature DB >> 35590298 |
Florin Eggmann1, Delia R Irani2, Patrizia A Fehlbaum2, Klaus W Neuhaus3,2.
Abstract
BACKGROUND: Evidence on the effect of magnification devices on procedure quality in restorative dentistry is scant. This study therefore aimed to assess, under simulated clinical conditions, if magnification loupes affect the quality of preparations carried out by undergraduate dental students.Entities:
Keywords: Dental education; Magnification device; Restorative dentistry; Undergraduate training; Visual acuity
Mesh:
Year: 2022 PMID: 35590298 PMCID: PMC9118579 DOI: 10.1186/s12903-022-02232-z
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 3.747
Age distribution of undergraduate dental students participating in the study
| Age (years) | N |
|---|---|
| 20–25 | 47 |
| 26–30 | 8 |
| 31–35 | 2 |
| 36–40 | 0 |
| 41–45 | 0 |
| 46–50 | 2 |
Fig. 1a Standardized acrylic bloc designed for preclinical restorative training. Only the O and S figures were assessed in the present study. b Preparation precision assessment based on side view photographs of the O figure: the evenness and the accuracy of depth of the cavities were evaluated by taking length measurements. The internal angles (α, β, γ, and δ) of the axial walls of the preparation were measured to assess the compliance with the required angles. c Preparation precision assessment based on top view photographs of the S figure: the parameter overpreparation and the parameter underpreparation quantified the area (red) outside the borderline and the area (yellow) inside the borderline of the S figure, respectively
Correlation of the visual acuity tests with parameters of preparation precision
| Preparation | Parameter | Conventional visual acuity test | Near vision acuity test | ||
|---|---|---|---|---|---|
| Spearman rank correlation coefficient | Spearman rank correlation coefficient | ||||
| S figure | Accuracy | 0.13 | 0.2562 | 0.28 | 0.2976 |
| Length of inaccurate preparation | − 0.11 | 0.3173 | − 0.22 | 0.0531 | |
| O figure | Depth of the outer cavity | 0.17 | 0.4558 | 0.18 | 0.3658 |
| Evenness of the outer cavity floor | − 0.11 | 0.0053 | − 0.05 | 0.1401 | |
| Depth of the inner cavity | 0.09 | 0.9417 | 0.04 | 0.3080 | |
| Evenness of the inner cavity floor | − 0.06 | 0.7220 | − 0.08 | 0.8490 | |
| Number of ledges | − 0.20 | 0.0683 | − 0.03 | 0.0440 | |
| Internal angles of the axial walls | − 0.11 | 0.5920 | − 0.23 | 0.0937 | |