Łukasz Pawik1, Malwina Pawik2, Emilia Wysoczańska1, Aleksandra Schabowska1, Piotr Morasiewicz3, Felicja Fink-Lwow4.
Abstract
We aimed to investigate changes in postural stability on a stable surface after the application of dynamic tape for patients with inversion ankle sprains. This study enrolled 30 patients (age 25.5 ± 8.0 years) with grade I and II ankle sprains, which occurred 7-21 days before enrolment. Postural stability (balance, coordination, feedback) was assessed before and after the application of dynamic tape using a stabilographic platform. Three 32-s exercises were performed on the stabilographic platform, one with eyes open, one with eyes closed and one with visual feedback. After the application of dynamic tape, an improvement was observed in terms of the mean radius of sway (4.2 ± 1.3 mm vs. 3.4 ± 0.9 mm; p = 0.012) and coordination (48.8 ± 19.2% vs. 59.3 ± 5.8%; p = 0.021). Selected balance parameters did not improve significantly in the tests with open and closed eyes. Asymmetric load improved for all tests, but significant differences were only observed with eyes closed (34.9 ± 24.4 vs. 41.7 ± 30.5; p < 0.01). We concluded that the use of dynamic tape after an ankle sprain significantly improved balance and coordination on a stable surface. The benefits were shown in terms of a significant improvement in the asymmetric load of the injured limb in comparison to the healthy limb during the test with closed eyes and a considerable improvement in the asymmetric load that was evaluated with visual feedback on a stable surface.Entities:
Keywords: ankle sprain; dynamic tape; kinesiology taping; postural stability; rehabilitation
Mesh:
Year: 2022 PMID: 35564686 PMCID: PMC9100756 DOI: 10.3390/ijerph19095291
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 4.614
Figure 1Stability measurement on a stable platform: (A) placement of feet (front view); (B) placement of feet (side view); (C) test with open eyes; (D) test with closed eyes; (E) test with visual feedback.
Figure 2Application of dynamic tape.
Results of balance parameters before and after the application of dynamic tape for eyes open and eyes closed on a stable surface.
| Parameter | Stable Surface | |||||
|---|---|---|---|---|---|---|
| Eyes Open | Eyes Closed | |||||
| Test without DT | Test with DT | Test without DT | Test with DT | |||
| R (mm) | 4.3 ± 1.8 | 3.9 ± 1.2 | 0.395 | 5.1 ± 2.1 | 4.3 ± 1.3 | 0.126 |
| A (cm2) | 515 ± 505 | 489 ± 271 | 0.438 | 757 ± 603 | 671 ± 491 | 0.348 |
| L (cm) | 373 ± 117 | 379 ± 96 | 0.501 | 476 ± 151 | 465 ± 133 | 0.663 |
| V (cm/s) | 11.7 ± 3.7 | 11.9 ± 3.0 | 0.501 | 15.0 ± 4.7 | 14.5 ± 4.1 | 0.663 |
A, surface area of the developed trajectory COP; DT, dynamic tape; L, length of the path of the COP point in all planes; R, mean radius of sways; V, mean velocity of the COP trajectory (L/time of recording).
Load distributions between affected and unaffected limbs on a stable surface.
| Load Distribution | |||||||
|---|---|---|---|---|---|---|---|
| Test | Test without DT | Test with DT | |||||
| Unaffected Limb (%) | Affected Limb (%) | Asymmetry † | Unaffected Limb (%) | Affected Limb (%) | Asymmetry † | ||
| Eyes Open | 59.4 ± 29.9 | 40.6 ± 29.9 | 53.7 ± 30.9 | 57.5 ± 28.6 | 42.5 ± 28.6 | 57.6 ± 31.5 | 0.573 |
| Eyes Closed | 53.2 ± 19.9 | 46.9 ± 20 | 34.9 ± 24.4 | 53.1 ± 12.8 | 46.9 ± 12.8 | 41.7 ± 30.5 | <0.01 |
| Feedback | 52.6 ± 14.2 | 47.4 ± 14.2 | 25.7 ± 19.0 | 53.0 ± 25.0 | 47.0 ± 25.0 | 24.1 ± 15.5 | 0.698 |
DT, dynamic tape; † load asymmetry between limbs; * value for the difference between the asymmetric load of the limbs before and after the application of dynamic tape.
Load distributions between the forefoot and heel on a stable surface.
| Load Distribution | |||||||
|---|---|---|---|---|---|---|---|
| Test | Test without DT | Test with DT | |||||
| Front (%) | Back (%) | Asymmetry † | Front (%) | Back (%) | Asymmetry † | ||
| Eyes Open | 51.6 ± 31.4 | 48.4 ± 31.4 | 55.0 ± 28.9 | 41.9 ± 31.0 | 58.1 ± 31.0 | 53.9 ± 33.9 | 0.892 |
| Eyes Closed | 43.9 ± 32.0 | 56.1 ± 32.0 | 56.5 ± 30.9 | 37.0 ± 33.2 | 63.0 ± 33.2 | 64.3 ± 28.7 | 0.319 |
| Feedback | 54.0 ± 10.9 | 46.0 ± 10.9 | 18.3 ± 14.0 | 49.0 ± 14.5 | 51.0 ± 14.5 | 24.2 ± 12.5 | 0.053 |
DT, dynamic tape; † load asymmetry between the limbs; * value for the difference between the asymmetry of load of the limbs before and after the application of dynamic tape.