Abstract
Aim: This study was aimed to analyze the stress generation and distribution for "polyether ether ketone (PEEK)" and metal cobalt-chromium (Co-Cr) at different locations of the tooth using finite element analysis (FEA), when they are casted-off as "Richmond crowns." Materials andEntities:
Keywords: Endodontically treated teeth; Richmond crown; finite element analysis; polyether ether ketone; stress
Year: 2022 PMID: 35558664 PMCID: PMC9089765 DOI: 10.4103/jcd.jcd_638_20
Source DB: PubMed Journal: J Conserv Dent ISSN: 0972-0707
Figure 1Model preparation and load application. (a) Axisymmetric model representing the various parts in cross section. (b) The final element model geometry obtained on the computer screen by the provision of various entities such as grids, lines, and patches. (c) The mesh of the tooth model was created by segmenting the entire tooth structure into small cubical forms to analyze the stress caused in each cube. (d) A static load of a 100N and 40N were simultaneously applied on the second premolar tooth in a vertical and oblique direction (30° angulations), respectively for both the materials (i.e., polyether ether ketone and Metal)
Modulus of elasticity and Poisson’s ratio for each component of the tooth
| Material | Youngs modulus (Gpa) | Poisson’s ratio |
|---|---|---|
| PEEK | 5.1 | 0.4 |
| Cr-Co | 210 | 0.33 |
| Gingiva | 0.003 | 0.45 |
| Alveolar bone | 1.37 | 0.3 |
| Cortical bone | 1.37 | 0.3 |
| Tooth (dentine) | 18.6 | 0.31 |
| PDL | 0.069 | 0.45 |
| Spongy bone | 1.37 | 0.3 |
| Gutta-percha | 0.69 | 0.45 |
PEEK: Polyether ether ketone, PDL: Periodontal ligament
Comparative evaluation of stress generation around the post between polyether ether ketone and Metal Richmond crown in which P value derived from independent t-test
| Group | Mean±SD |
|
|
|---|---|---|---|
| PEEK (around post) | 2.813±0.166 | 20.28 | 0.030* |
| Metal (around post) | 16.113±1.123 | ||
| PEEK (around trabecular bone) | 0.570±0.010 | 68.068 | 0.001* |
| Metal (around trabecular bone) | 1.004±0.004 | ||
| PEEK (around cortical bone) | 3.526±0.661 | 3.408 | 0.027* |
| Metal (around cortical bone) | 5.887±1.001 |
*Statistically significant. PEEK: Polyether ether ketone, SD: Standard deviation
Figure 2Finite element analysis. (a) Total deformation caused in polyether ether ketone Richmond crown. (b) Maximum stress caused in PEEK Richmond crown. (c) Total deformation caused in the Metal Richmond crown. (d) Maximum stress caused in Metal Richmond crown