Mohammed M Rahman1,2, M M Alam3, Abdullah M Asiri1,2. 1. Chemistry Department, King Abdulaziz University, Faculty of Science P.O. Box 80203 Jeddah 21589 Saudi Arabia. 2. Center of Excellence for Advanced Material Research (CEAMR), King Abdulaziz University P.O. Box 80203 Jeddah 21589 Saudi Arabia. 3. Department of Chemical Engineering and Polymer Science, Shahjalal University of Science and Technology Sylhet 3100 Bangladesh mmalamsust@gmail.com +880-821548976.
Nitro-organic compounds (nitro-phenols) are well known as anthropogenic, toxic, inhibitory, and bio-refractory compounds and have vast industrial applications in the manufacture of a variety of useful products such as pharmaceuticals, industrial chemicals, pesticides, organic dyes, fungicides, insecticides, explosives, and aniline.[1] Therefore, the EPA (Environmental Protection Agency) and EU (European Union) have enlisted NPs as hazardous because of their highly toxic behavior towards the environment including human, animal, plants, aquatic life, and living organisms.[2-4] NPs may cause various harmful effects in human body, particularly cancer, generate poisoning, and tumors in the urinary tract.[5,6] The NPs are soluble in water, and due to the numerous manmade activities, they have not only been detected in industrial effluents, but also in fresh water and marine environment.[7] To protect the public health and the environment from harmful effects of NPs, it is obligatory to develop an efficient and sensitive portable device (chemical sensor) that will be used to detect NPs in the working place, environment, and public health sector.[8] The existing typical methods, such as spectrophotometry,[9] fluorescence,[10] gas chromatography,[11] capillary electrophoresis,[12] and high performance liquid chromatography,[13] are applied to detect NPs. However, these traditional methods have several disadvantages such as being costly and time consuming, requiring heavy instrumentation, and are complicated to use outdoors. On the other hand, the electrochemical method has useful features including low cost, easy operation, short response time, portable simple instrumentation, and selectivity with high sensitivity.[14]The transition metal oxides with multiple oxidation states such as Fe2O3, Co3O4, MnO2, and CrO2 are extensively applied as a successive electron mediators to detect NPs.[15] An efficient NP chemical sensor fabricated with α-MnO2 nanotubes had exhibited the sensitivity of 19.18 μA mM−1 cm−2 and detection limit of 0.1 mM.[16] Another NP chemical sensor based on Mn2O3/ZnO nanoparticles showed the sensitivity 4.6667 μA μM−1 cm−2 with the detection limit 0.83 nM.[17] In this decade, carbon nanotubes impregnated with transition metal oxides are extensively considered for the detection of environmental toxins, and this is becoming increasingly popular ever since the first invention.[18-20] It has been reported that the NP sensor fabricated with hydride components of carbon nanotube and phthalocyanine cobalt(ii) shows an outstanding detection limit 0.2 μM with a linear dynamic range from 1 μM to 1.9 mM.[21] Besides this, another talented NP chemical sensor assembled with a poly(diallyldimethylammonium chloride)-functionalized graphene composite has exhibited a dynamic result of detection limit 0.02 μM with a wider linear dynamic range from 0.06 to 110 μM.[22]Due to the high toxicity of 2-NP, sustainable development of methods for its selective detection is urgently needed. Therefore, an initiative has been taken for efficient detection of 2-NP by an electrochemical sensor constructed with Co3O4/Al2O3 NSs. A thin layer of Co3O4/Al2O3 NSs with a conducting binding agent (5% Nafion suspension in ethanol) was deposited on GCE to obtain a working electrode of 2-NP chemical sensor. The assembled Co3O4/Al2O3 NS/binder/GCE was applied successfully to detect 2-NP by a reliable electrochemical approach. To the best of our knowledge, the exploration of environmental toxin (2-NP) using a chemical sensor fabricated with active Co3O4/Al2O3 NSs has been reported for the first time herein. Therefore, it may be concluded that the 2-NP chemical sensor based on Co3O4/Al2O3 NSs onto GCE is a novel introduction in the field of sensor technology with promising applications in environmental toxin analysis.
Experimental
Materials and methods
The analytical grade chemicals cobalt(ii) chloride (CoCl2), aluminum chloride (AlCl3), and ammonium hydroxide (NH4OH) were obtained from the Sigma-Aldrich company and used as received to prepare Co3O4/Al2O3 NSs. To execute this study, M-tolylhydrazine (M-THyd), 2,4-dinitrophenol (2,4-DNP), 2-nitrophenol (2-NP), methanol (M), 3-methylaniline (3-MA), 3-chlorophenol (3-CP), ammonium hydroxide (AH), 3,4-diaminotoluene (3,4-DAT), 3-methoxyphenylhydrazine (3-MPHyd), bisphenol A (BPA), Nafion (5% Nafion suspension in ethanol), monosodium phosphate, and disodium phosphate were purchased from Sigma-Aldrich company. To explore the FTIR and UV-vis spectra, the produced Co3O4/Al2O3 NSs were analyzed using a Thermoscientific NICOLET iS50 FTIR (Madison, WI, USA) and 300 UV/visible spectrophotometer (Thermoscientific), respectively. The binding energies of Co, Al, and O and the corresponding oxidation states were measured by XPS analysis using a K-α1 spectrometer (thermo scientific, K-α1 1066) with a radiation source (A1Kα1, Beam spot size = 300.0 μm, pass energy = 200.0 eV, and pressure ∼ 10−8 torr). The optical properties, such as the arrangement of molecules, analysis of elements, morphological structure, and particle size, of synthesized NSs were investigated by implementation of FESEM (JEOL, JSM-7600F, Japan) and XEDS. Besides this, the phase (crystallinity of nanoparticles) identification was carried out by the execution of XRD analysis on the prepared Co3O4/Al2O3 NSs under ambient conditions. A slurry of NSs was used to coat the GCE with a conducting binder, and the resulting working electrode was implemented successfully to detect 2-NP in an aqueous medium. The electrochemical measurement was executed by a Keithley electrometer (6517A, USA) under room condition.
Preparation of Co3O4/Al2O3 NSs by a wet-chemical process
The wet-chemical process (co-precipitation) is an extensively used technique to prepare doped nanomaterials at low temperatures. This method involves three successive steps: (i) precipitation of two or more metal hydroxides in aqueous media, (ii) drying of separated precipitate, and (iii) calcination of dried precipitate in a high temperature muffle furnace. For the execution of this study, the predetermined weights of cobalt chloride (CoCl2) and aluminum chloride (AlCl3) were dissolved in 100.0 mL de-ionized (DI) water in a 250.0 mL conical flask. Then, a 0.1 M solution of NH4OH was added to the resultant solution dropwise under continuous magnetic stirring, and the pH of the solution was adjusted to around 10.5. Under this condition, the metal ions were precipitated out quantitatively in the form of Co(OH)2/Al(OH)3. The precipitate was separated out from water and then dried in an oven at 105 °C. Subsequently the dried sample was calcined at 500 °C for 6 hours in a high temperature furnace for the metal hydroxides to transform into the metal oxide form Co3O4/Al2O3 in presence of atmospheric oxygen. The calcined sample in the oxide form was ground in a mortar into nanosized particles. The reaction scheme is supposed to be as follows:In aqueous medium:In the muffle furnace:In the wet-chemical process, the precipitation of metal ion in the form of metal hydroxide is dependent on the value of Ks (solubility product constant) in an aqueous medium. At the pH 10.5, the Ks values for Al(OH)3 and Co(OH)2 are 3 × 10−34 and 5.92 × 10−15, respectively.[34] As 0.1 M ammonium hydroxide solution is added dropwise to the resultant solution, the OH− concentration increases gradually. Consequently, with the lower Ks value of Al(OH)3, aluminum hydroxide starts to precipitate first and forms nuclei of crystals.[23] Then, with an increase in the OH− ion concentration, the crystallites of aluminum hydroxide start to aggregate. Due to the addition of ammonium hydroxide in the resulting solution, the pH continues to increase for the adjustment of the reactor during preparation of nanomaterials. Then, cobalt hydroxide also starts to precipitate, which is adsorbed on crystallites of aluminum hydroxide. This similar tendency of growth pattern of nanomaterials has been reported elsewhere.[24-26] Subsequently, the obtained crystals of metal hydroxides are sequentially washed with water, ethanol, and acetone and dried overnight at 105 °C in an oven. After this, the dried sample is subjected to calcination at higher temperatures in a furnace (Barnstead Thermolyne, 6000 Furnace, USA) at 500 °C for 6 hours. The schematic of the formation mechanism of Co3O4/Al2O3 NSs is presented in Scheme 1. To obtain the nano-sized particles, the calcined Co3O4/Al2O3 NSs were ground in a mortar. The prepared NSs were applied for the detection of 2-NP by an electrochemical approach under ambient conditions.
Scheme 1
The growth mechanism of Co3O4/Al2O3 NSs produced by the low-temperature wet-chemical method.
Fabrication of GCE with Co3O4/Al2O3 NSs
A slurry of Co3O4/Al2O3 NSs was prepared in ethanol and coated on a GCE as a very thin layer. To enhance the physical binding strength between NSs and GCE, a drop of Nafion (5% Nafion suspension in ethanol) was added. The assembled Co3O4/Al2O3 NS/binder/GCE was kept inside an oven at 34.0 °C for enough time to dry the conducting film entirely. The desired electrochemical cell was organized with the Co3O4/Al2O3NS/binder/GCE and a Pt-wire (diameter 1.5 mm) as the working electrode and the counter electrode, respectively. To execute the sensor analytical performances, a series of 2-NP solutions based on the concentration ranging from 0.01 nM to 0.1 mM was prepared and used as a target analyte. The sensitivity of the anticipated chemical sensor was estimated from the slope of the calibration curve accomplished as resultant-current versus applied-concentration of 2-NP. The linear dynamic range (LDR) was measured from the maximum linearity (regression coefficient, r2) of calibration curve, and detection limit was obtained from the signal to noise ratio of 3. The used electrometer is a simple two-electrodes system. The volume of the buffer solution (PBS) in the measuring electrochemical cell was maintained constant at 10.0 mL during the execution of this study.
Results and discussions
Structural analyses
The XRD (powder X-ray diffraction) patterns are able to provide detailed information about unit cell dimensions (phase crystallinity), and this technique was implemented on Co3O4/Al2O3 NSs with the radiation source Cu–Kα1 (λ = 1.54178 Å) in the range of 10–80°, and the corresponding scanning speed was 2° min−1. According to the XRD spectrum presented in Fig. 1, the synthesized Co3O4/Al2O3 NSs contain well-assorted phases of Co3O4 and Al2O3. As observed from the Fig. 1, the reflected peaks of Co3O4 indices as β are (111), (220), (222), (400), (533), (622), (440), and (511), having great similarities with the previous reports.[27-30] Beside this, the observed diffracted peaks for Al2O3 indices as θ are (012), (104), (024), (220), (110), and (116), which have been identified by previous authors[31-35] and JCPDS no. 29-0063 to be belonging to Al2O3. Based on the Scherrer equation, the crystal size of the nanoparticles can be calculated from the XRD diffraction pattern.Herein, λ represents the wavelength (X-ray radiation = 1.5418 Å) and β is full width at half maxima (FWHM), corresponding to most intense peak, and θ is the diffracting angle.[36] From the eqn (vi), the calculated crystal size (following the Scherrer equation) is equal to 30.86 nm. The optical analysis of Co3O4/Al2O3 NSs is also performed and presented in the ESI section (Fig. S4†).
Fig. 1
Powder XRD pattern of the Co3O4/Al2O3 nanostructures for the structural analysis.
Morphological and elemental analyses
The morphological and elemental analysis of synthesized Co3O4/Al2O3 NSs were investigated by FESEM and EDS analysis, as illustrated in Fig. 2. The typical FESEM images with high to low magnification are presented in the Fig. 2(a and b), and it is clearly visible that the synthesized Co3O4/Al2O3 materials are nanosheets in terms of shape.[37-39] The FESEM investigation is similar with the results of EDS analysis, as shown in Fig. 2(c and d). According to the EDS analysis, the composition of Co3O4/Al2O3 NSs is O 46.95%, Al 19.74%, and Co 33.3%. Besides these, any other peak is not visible; therefore, it can be concluded that the prepared Co3O4/Al2O3 NSs consist of cobalt, aluminum, and oxygen only.[40-42]
Fig. 2
Morphological and elemental analyses (a and b) FESEM analysis from high to low magnified images and (c and d) elemental analysis of Co3O4/Al2O3 nanostructures.
Binding energy analysis
The synthesized NSs were subjected to XPS investigation with an X-ray beam. The XPS spectrum is obtained when the atoms of the sample absorb the kinetic energy of X-ray beam and the electrons of outer spin orbital jump from lower to higher energy level. The atomic composition with the corresponding chemical formula and the oxidation state of the species present in the nanomaterial can be scrutinized efficiently by this practice.[43-45] The core level XPS spectra of Co 2p, Al 2p, and O 1s are presented in Fig. 3. The high resolution of Co 2p spectrum shows two obvious dominated peaks centered at 781.0 and 796.0 eV. These two sharp peaks can be ascribed to Co 2p3/2 and Co 2p1/2 orbits and obviously verify the presence of Co3+. The projected two satellite peaks of Co 2p3/2 and Co 2p1/2 are at 787.0 and 803.0 eV, respectively. These two peaks can be attributed to the presence of Co2+ in the synthesized NSs, as illustrated in Fig. 3(c).[46-50] Therefore, the presence of dominant and satellite peaks of Co 2p spin orbitals indicate the co-existence of Co(ii) and Co(iii) on the surface of synthesized Co3O4/Al2O3 NSs. The O 1s exhibit a peak at 531.3 eV, which is presented in Fig. 3(b) and attributed to O2− in Al2O3.[51-55] The XPS spectra of Al 2p is concentrated at 73.3 and 75.1 eV, and the peaks of Al 2p at 75.1 eV are ascribed to Al3+–O2− bonds in Al2O3, as illustrated in Fig. 3(d).[56-59] The different states of O 1s, Al 2p, and Co 2p are also quantified and presented in the ESI section (Fig. S5†).
Fig. 3
Binding energy analysis by XPS study of Co3O4/Al2O3 NSs (a) full spectrum, (b) O 1s level, (c) spin orbit Co 2p level, and (d) spin orbit of Al 2p level.
Applications: sensing of 2-NP by Co3O4/Al2O3 NSs
The selective detection of 2-NP was executed in the optimized buffer system, and this performance was carried out by the implementation of Co3O4/Al2O3 NS/binder/GCE as the working electrode. To enhance the binding strength between NSs and GCE, a drop of Nafion was added. Nafion not only enhances the binding strength, but also increases stability, conductivity, and electron transfer rate of the electrode.[60,61] Thus, the prepared electrode exhibited the advantages of high stability in air as well as in chemical environment, enhanced electrochemical performance during the detection of target analyte (2-NP), and can be easily subjected to performances, assembling, and fabrication, and above all, safe chemo-characteristics. Therefore, the proposed chemical sensor Co3O4/Al2O3 NS/binder/GCE was successfully used to detect 2-NP in an aqueous medium. During the performance of 2-NP chemical sensor, applied I–V was measured on thin-film of Co3O4/Al2O3 NS/binder/GCE, and the holding time in the electrometer was set as 1.0 s. A possible reduction mechanism of 2-NP is illustrated in Scheme 2. As observed from Scheme 2, the electrons are accepted from the applied current to reduce 2-NP into 2-AP (2-aminophenol). Therefore, the species of reactive 2-NP are adsorbed on the Co3O4/Al2O3 NS surface and reduced to 2-aminophenol, as shown in reaction (vii) to (ix). Since the electrons are required to reduce 2-NP, the electrochemical response (I–V) is inversely proportional to the corresponding concentration of 2-NP.[62-65] A schematic of the detection process of 2-NP based on Co3O4/Al2O3 NS/binder/GCE sensor is demonstrated in Scheme 2.
Scheme 2
The expected sensing mechanism for the determination of 2-NP by Co3O4/Al2O3 NSs on sensor probe.
The possible suggested reduction mechanism of 2-NP is presented in the reaction (vii) and (ix).The synthesized NSs are not responsive equally in all buffers to applied I–V. Therefore, for obtaining the maximum output of the I–V responses, the pH of the measuring buffer system was necessary to be optimized for the Co3O4/Al2O3 NS/binder/GCE. Fig. 4(a) represents the I–V response of pH ranging from 5.7 to 8.0. Obviously, among the tested buffer system, the best I–V response was attained at pH 6.5. Then, a number of environmental toxins have been investigated at the concentration level of 1.0 μM and pH = 7.5 with the proposed chemical sensor. The electrochemical responses of M-THyd, 2,4-DNP, 2-NP, methanol, 3-MA, 3-CP, AH, 3,4-DAT, 3-MPHyd, and BPA are illustrated in Fig. 4(b). Obviously, the electrochemical response of 2-NP has the highest intensity under experimental conditions. The reproducibility test of a chemical sensor provides the evidence of reliability. Therefore, this test was performed at 0.1 μM concentration of 2-NP, and the resulting data is represented in Fig. 4(c). As seen in the Fig. 4(c), the replicated six runs are practically indistinguishable under an identical condition. The electrochemical responses are unchanged even after washing of electrode in each trial. Therefore, this test provides the evidence of reliability, and the projected 2-NP chemical sensor can be applied in the real field successively. The relative standard deviation of the reproducibility performances (RSD) is estimated, and it is found to be 1.54 at an applied potential of +1.5 V. The response time is another tool to measure the efficiency of a chemical sensor, and this test has been performed using a 0.1 μM solution of 2-NP. As illustrated in Fig. 4(d), steady response is achieved in about around 10.5 s, and the obtained result may be considered highly satisfactory.
Fig. 4
Optimization of 2-NP with Co3O4/Al2O3 NSs. (a) pH optimization, (b) selectivity, (c) repeatability, and (d) response time.
Fig. 5(a) presents the I–V response of 2-NP for various concentrations ranging from 0.01 nM to 0.1 mM. Evidently, this is a very wide range, and the applied potential is higher than +1.0 V. As shown in Fig. 5(a), I–V responses are distinguishable from lower to higher concentration of 2-NP. To evaluate the analytical performance of the projected chemical sensor, the current data at an applied potential of +1.5 V has been obtained from Fig. 5(a) and plotted as current vs. concentration of 2-NP in the Fig. 5(b), which is known as a calibration plot. This calibration plot is found to be linear with the regression co-efficient value r2 = 0.99 along the x-axis in logarithmic scale. The sensitivity of 2-NP chemical sensor is estimated from the slope of calibration curve, and it is equal to 54.9842 μA μM−1 cm−2. The linear dynamic range (LDR) is found to be from 0.01 nM to 0.01 mM. At a signal to noise ratio equal to 3, the limit of detection (LOD) and limit of quantity (LOQ) were calculated to be 1.73 ± 0.02 pM and 5.77 ± 0.02 pM, respectively. Obviously, the Co3O4/Al2O3 NS/binder/GCE electrode could be used to determine 2-NP in an aqueous medium in a wide concentration range. The stability performance of electrode based on Co3O4/Al2O3 NSs has been evaluated in the detection of 2-NP under identical conditions for intra-days and inter-day, as presented in Fig. S1 and S2,† respectively, in the ESI section.† Therefore, it can be concluded from Fig. S1 and S2† that the fabricated electrode is able to perform efficiently in long-term. The reliable measurement of 2-NP with other toxins such as 3-CP and 4-NP in an aqueous medium is illustrated in Fig. S3 in the ESI.† According to this figure, the toxin 3-CP and 4-NP have not shown any remarkable interference effect on the projected chemical sensor during the sensing of 2-NP.
Fig. 5
Performance of 2-NP sensor. (a) Concentration variation of 2-NP based on Co3O4/Al2O3 NSs/GCE by I–V method, (b) calibration curve (inset: log[2-NP conc.] vs. current).
As observed from Fig. 5(a), the electrochemical response of 2-NP chemical sensor based on active Co3O4/Al2O3 NS/GCE increases with a decrease in the concentration of 2-NP. Therefore, the highest I–V response is found at lowest concentrations of 2-NP. During the sensing of 2-NP by Co3O4/Al2O3 NS/GCE electrode, a small surface coverage due to the adsorption of few 2-NP molecules on surface of electrode occurs in the initial stage, and corresponding reduction reaction of 2-NP starts progressively. With enrichment of analyte (2-NP), the rate of reaction is increased, and the higher surface coverage is obtained. With further enrichment of 2-NP concentration in the sensing medium, the reduction reaction comes to equilibrium, and the surface coverage approaches its saturation state. With an additional increase in the analyte concentration, a steady state equilibrium I–V response is observed, and a saturated surface coverage is accomplished. Therefore, it can be summarized that the proposed 2-NP chemical sensor based on the Co3O4/Al2O3 NS/GCE assembly can be applied for efficient detection of the targeted toxin (2-NP). As indicated, the proposed 2-NP chemical sensor exhibits reasonable short response time of around 10.5 s, and it should be mentioned that 10.5 s is needed by the 2-NP chemical sensor to attain steady state saturation. Since the proposed 2-NP chemical sensor demonstrates a high sensitivity of 54.9842 μA μM−1 cm−2, it can be accredited that it has very good adsorption capacity and active catalytic decomposition ability.[66-70] The interference effect is studied in the presence of different phenolic compounds and their derivatives, such as 2-NP, 2,4-DNP, BPA, and 3-CP, under identical conditions, as presented in Table 1.
Measurement of interference effect by Co3O4/Al2O3 NS/GCE
Toxins
Observed currenta (μA) at +1.5 V
Averageb (μA)
RSDc (%)
R1
R2
R3
R4
2-NP
26.756
26.298
25.839
26.347
26.310
1.42
2,4-DNP
3.699
3.613
3.527
3.643
3.621
1.98
BPA
22.839
23.137
22.410
21.981
22.592
2.23
3-CP
23.688
22.875
23.525
24.175
23.566
2.28
Mean of four repeated (R) determination (signal to noise ratio 3) with Co3O4/Al2O3 NSs/GCE at 0.1 μM concentration.
The average observed current of the corresponding toxin.
Relative standard deviation value indicates precision among four repeated determinations.
Mean of four repeated (R) determination (signal to noise ratio 3) with Co3O4/Al2O3 NSs/GCE at 0.1 μM concentration.The average observed current of the corresponding toxin.Relative standard deviation value indicates precision among four repeated determinations.According to analytical performance, such as selectivity, detection limit, and dynamic linear range, of the chemical sensor, the proposed 2-NP chemical sensor fabricated based on Co3O4/Al2O3 NS/GCE showed a reasonably qualified performance as compared to the chemical sensors based on the various transition nanostructured metal oxides, and a comparison is illustrated in Table 2. In brief, the fabricated 2-NP chemical sensor is simple and efficient to detect 2-NP by applying current versus potential electro-chemical approaches. The sensing performance, such as detection limit (LD), linear dynamic range (LDR), and sensitivity, of earlier tested 2-NP chemical sensors are associated and summarized in Table 2.[70-75]
Comparative performances of various nanomaterials or nanocomposites fabricated electrode for the detection of 2-NP by electrochemical approachesa
The proposed 2-NP chemical sensor based on Co3O4/Al2O3 NSs was employed for validation to detect and quantify 2-NP in real samples to test its applicability in practical field. The samples were obtained from various sources such as industrial effluent, extracts from PC baby-bottle, and seawater. The results of the analyses are presented in Table 3 and seem quite satisfactory.
Measured concentration of 2-NP analytes in real environmental samples
Sample
Added 2-NP concentration
Determined 2-NP concentrationa by Co3O4/Al2O3 NSs/GCE
Recoveryb (%)
RSDc (%) (n = 3)
Industrial effluent
0.100 μM
0.0991 μM
99.1
2.11
0.100 μM
0.1032 μM
103.2
0.100 μM
0.1022 μM
102.2
Plastic baby bottle
0.100 μM
0.1019 μM
101.9
0.83
0.100 μM
0.1032 μM
103.2
0.100 μM
0.1035 μM
103.5
0.100 μM
0.1053 μM
105.3
Sea water
0.100 μM
0.1059 μM
105.9
1.02
0.100 μM
0.1074 μM
107.4
Mean of three repeated determinations (signal to noise ratio 3) with Co3O4/Al2O3 NSs/GCE.
Concentration of 2-NP determined/concentration taken.
Relative standard deviation value indicates precision among three repeated determinations.
Mean of three repeated determinations (signal to noise ratio 3) with Co3O4/Al2O3 NSs/GCE.Concentration of 2-NP determined/concentration taken.Relative standard deviation value indicates precision among three repeated determinations.
Conclusions
The reliable wet-chemical process was used to prepare NSs of Co3O4/Al2O3 at low temperature. Later, a thin layer of NSs was deposited onto GCE with a conducting binder to fabricate the working electrode for the 2-NP chemical sensor development. The calcined NSs were characterized by FESEM, EDS, XPS, FTIR, UV/vis, and XRD and applied to successively detect 2-NP in an aqueous medium. The proposed 2-NP chemical sensor based on Co3O4/Al2O3 NSs displayed higher sensitivity, lower detection limit, broad linear dynamic ranges, and selectivity towards 2-NP by reliable I–V method. The applied current to concentration of 2-NP is linear over the concentration range from 0.01 nM to 0.01 mM with a detection limit of 1.73 ± 0.02 pM, LOQ of 5.77 ± 0.02 pM, and sensitivity of 54.9842 μA μM−1 cm−2. This approach introduced a well-organized route of efficient chemical sensor development for environmental pollutants in a broad scales.
Authors: Mohammed M Rahman; Sher Bahadar Khan; M Faisal; Malik Abdul Rub; Abdulrahman O Al-Youbi; Abdullah M Asiri Journal: Talanta Date: 2012-08-02 Impact factor: 6.057
Authors: Xi Luo; Wai-Tung Lee; Guozhong Xing; Nina Bao; Adnan Yonis; Dewei Chu; Jiunn Lee; Jun Ding; Sean Li; Jiabao Yi Journal: Nanoscale Res Lett Date: 2014-11-22 Impact factor: 4.703
Authors: Mohammed M Rahman; George Gruner; Mohammed Saad Al-Ghamdi; Muhammed A Daous; Sher Bahadar Khan; Abdullah M Asiri Journal: Chem Cent J Date: 2013-03-28 Impact factor: 4.215
Authors: Dina F Katowah; Mahmoud A Hussein; M M Alam; T R Sobahi; M A Gabal; Abdullah M Asiri; Mohammed M Rahman Journal: RSC Adv Date: 2019-10-16 Impact factor: 4.036
Authors: Md Abdus Subhan; Tanjila Parvin Rifat; Pallab Chandra Saha; M M Alam; Abdullah M Asiri; Mohammed M Rahman; Sonia Akter; Topu Raihan; A K Azad; Jamal Uddin Journal: RSC Adv Date: 2020-03-19 Impact factor: 4.036