Literature DB >> 22178284

A graphene oxide-based electrochemical sensor for sensitive determination of 4-nitrophenol.

Junhua Li1, Daizhi Kuang, Yonglan Feng, Fuxing Zhang, Zhifeng Xu, Mengqin Liu.   

Abstract

A graphene oxide (GO) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of 4-nitrophenol (4-NP). The GO-based sensor was characterized by scanning electron microscope, atomic force microscopy and electrochemical impedance spectroscopy. The electrochemical behaviors of 4-NP at the GO-film coated GCE were investigated in detail. In 0.1M acetate buffer with a pH of 4.8, 4-NP yields a very sensitive and well-defined reduction peak at the GO-modified GCE. It is found that the GO film exhibits obvious electrocatalytic activity toward the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. Various kinetic parameters such as transfer electron number, transfer proton number and standard heterogeneous rate constant were calculated, and various experimental parameters were also optimized. Under the optimal conditions, the reduction peak current varies linearly with the concentration of 4-NP ranging from 0.1 to 120 μM, and the detection limit is 0.02 μM at the signal noise ratio of 3. Moreover, the fabricated sensor presented high selectivity and long-term stability. This electrochemical sensor was further applied to determine 4-NP in real water samples, and it showed great promise for simple, sensitive, and quantitative detection of 4-NP.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22178284     DOI: 10.1016/j.jhazmat.2011.11.076

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  29 in total

1.  Stimuli-Responsive Templated Polymer as a Target Receptor for a Conformation-based Electrochemical Sensing Platform.

Authors:  Habib M N Ahmad; Gaurab Dutta; John Csoros; Bo Si; Rongfang Yang; Jeffrey M Halpern; W Rudolf Seitz; Edward Song
Journal:  ACS Appl Polym Mater       Date:  2020-12-09

2.  A nanocomposite consisting of reduced graphene oxide and electropolymerized β-cyclodextrin for voltammetric sensing of levofloxacin.

Authors:  Mohammad Hossein Ghanbari; Faezeh Shahdost-Fard; Alireza Khoshroo; Mehdi Rahimi-Nasrabadi; Mohammad Reza Ganjali; Marcin Wysokowski; Tomasz Rębiś; Sonia Żółtowska-Aksamitowska; Teofil Jesionowski; Parvaneh Rahimi; Yvonne Joseph; Hermann Ehrlich
Journal:  Mikrochim Acta       Date:  2019-06-13       Impact factor: 5.833

3.  Dispersed copper nanoparticles promote the electron mobility of nitrogen-rich graphitized carbon aerogel for electrochemical determination of 4-nitrophenol.

Authors:  Shanhe Gong; Xinxin Xiao; Daniel Kobina Sam; Botao Liu; Wei Wei; Weiting Yu; Xiaomeng Lv
Journal:  Mikrochim Acta       Date:  2019-11-28       Impact factor: 5.833

4.  A new strategy for the sensitive electrochemical determination of nitrophenol isomers using β-cyclodextrin derivative-functionalized silicon carbide.

Authors:  Shilian Wu; Shuangmei Fan; Shuang Tan; Jiaqiang Wang; Can-Peng Li
Journal:  RSC Adv       Date:  2018-01-03       Impact factor: 3.361

5.  Ultrasensitive Detection of Ferulic Acid Using Poly(diallyldimethylammonium chloride) Functionalized Graphene-Based Electrochemical Sensor.

Authors:  Lin-Jie Liu; Xia Gao; Pei Zhang; Shi-Lan Feng; Fang-di Hu; Ying-Dong Li; Chun-Ming Wang
Journal:  J Anal Methods Chem       Date:  2014-05-12       Impact factor: 2.193

6.  High Sensitive Sensor Fabricated by Reduced Graphene Oxide/Polyvinyl Butyral Nanofibers for Detecting Cu (II) in Water.

Authors:  Rui Ding; Zhimin Luo; Xiuling Ma; Xiaoping Fan; Liqun Xue; Xiuzhu Lin; Sheng Chen
Journal:  Int J Anal Chem       Date:  2015-01-28       Impact factor: 1.885

7.  Efficient 2-Nitrophenol Chemical Sensor Development Based on Ce2O3 Nanoparticles Decorated CNT Nanocomposites for Environmental Safety.

Authors:  Mohammad M Hussain; Mohammed M Rahman; Abdullah M Asiri
Journal:  PLoS One       Date:  2016-12-14       Impact factor: 3.240

8.  Photo-reduced Cu/CuO nanoclusters on TiO2 nanotube arrays as highly efficient and reusable catalyst.

Authors:  Zhao Jin; Chang Liu; Kun Qi; Xiaoqiang Cui
Journal:  Sci Rep       Date:  2017-01-10       Impact factor: 4.379

9.  A graphene-based electrochemical sensor for rapid determination of phenols in water.

Authors:  Kun Chen; Zai-Li Zhang; Yong-Mei Liang; Wei Liu
Journal:  Sensors (Basel)       Date:  2013-05-13       Impact factor: 3.576

10.  Chemo-sensors development based on low-dimensional codoped Mn2O3-ZnO nanoparticles using flat-silver electrodes.

Authors:  Mohammed M Rahman; George Gruner; Mohammed Saad Al-Ghamdi; Muhammed A Daous; Sher Bahadar Khan; Abdullah M Asiri
Journal:  Chem Cent J       Date:  2013-03-28       Impact factor: 4.215

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.