Literature DB >> 35527159

Fabrication of heparinized small diameter TPU/PCL bi-layered artificial blood vessels and in vivo assessment in a rabbit carotid artery replacement model.

Zhiping Fang1, Yonghao Xiao1, Xue Geng1, Liujun Jia2, Yuehao Xing3, Lin Ye1, Yongquan Gu3, Ai-Ying Zhang1, Zeng-Guo Feng4.   

Abstract

Increasingly growing problems in vascular access for long-term hemodialysis lead to a considerable demand for synthetic small diameter vascular prostheses, which usually suffer from some drawbacks and are associated to high failure rates. Incorporating the concept of in situ tissue engineering (TE) into synthetic small diameter blood vessels, for example, thermoplastic poly(ether urethane) (TPU) ones, could provide an alternative approach for vascular access that profits from the advantages of excellent mechanical properties of synthetic polymer materials (early cannulation) and unique biointegration regeneration of autologous neovascular tissues (long-term fistulae). In this study, a kind of heparinized small diameter (d = 2.5 mm) TPU/poly(ε-caprolactone) (TPU/PCL-Hep) bi-layered blood vessels was electrospun with an inner layer of PCL and an outer layer of TPU. Afterward, the inner surface heparinization was conducted by coupling H2N-PEG-NH2 to the corroded PCL layer and then heparin to the attached H2N-PEG-NH2 via the EDCI/NHS chemistry. Herein a heparinized PCL inner layer could not only inhibit thrombosis, but also provide sufficient space for the neotissue regeneration via biodegradation with time. Meanwhile, a TPU outer layer could confer the vascular access the good mechanical properties, such as flexibility, viability and fitness of elasticity between the grafts and host blood vessels as evidenced by the adequate mechanical properties, such as compliance (4.43 ± 0.07%/ 100 mmHg), burst pressure (1447 ± 127 mmHg) and suture retention strength (1.26 ± 0.07 N) without blood seepage after implantation. Furthermore, a rabbit carotid aortic replacement model for 5 months was demonstrated 100% animal survival and 86% graft patency. Puncture assay also revealed the puncture resistance and self-sealing (hemostatic time < 2 min). Histological analysis highlighted neotissue regeneration, host cell infiltration and graft remodeling in terms of extracellular matrix turnover. Altogether, these results showed promising aspects of small diameter TPU/PCL-Hep bi-layered grafts for hemodialytic vascular access applications.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrospinning; Heparin; In situ tissue engineering; Poly(ε-caprolactone); Thermoplastic poly(ether urethane) elastomer; Vascular access

Mesh:

Substances:

Year:  2021        PMID: 35527159     DOI: 10.1016/j.msec.2021.112628

Source DB:  PubMed          Journal:  Biomater Adv        ISSN: 2772-9508


  2 in total

Review 1.  Clinical Application for Tissue Engineering Focused on Materials.

Authors:  Takahiro Kitsuka; Rikako Hama; Anudari Ulziibayar; Yuichi Matsuzaki; John Kelly; Toshiharu Shinoka
Journal:  Biomedicines       Date:  2022-06-17

2.  Design of a Personalized Nasal Device (Matrix-Piston Nasal Device, MPD) for Drug Delivery: a 3D-Printing Application.

Authors:  Ioanna-Maria Menegatou; Paraskevi Papakyriakopoulou; Dimitrios M Rekkas; Paraskevas Dallas; Georgia Valsami
Journal:  AAPS PharmSciTech       Date:  2022-07-28       Impact factor: 4.026

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.