Literature DB >> 31558505

Application of High-Resolution C-Arm CT Combined with Streak Metal Artifact Removal Technology for the Stent-Assisted Embolization of Intracranial Aneurysms.

T-F Li1,2, J Ma1,2, X-W Han3,2, P-J Fu1,2, R-N Niu4, W-Z Luo5, J-Z Ren1,2.   

Abstract

BACKGROUND AND
PURPOSE: Metal artifacts from coils and stents limit the level of detail in C-arm CT images of stent attachment and coiling attenuation in the aneurysm neck. We evaluated the utility of high-resolution C-arm CT combined with streak metal artifact removal technology for stent-assisted embolization of intracranial aneurysms.
MATERIALS AND METHODS: From October 2017 to July 2018, the First Affiliated Hospital of Zhengzhou University treated 107 patients with intracranial aneurysms (118 aneurysms in total) with stent-assisted embolization. Conventional C-arm CT and high-resolution C-arm CT scanning of the stented area were performed during and after treatment. 3D images were reconstructed with and without streak metal artifact removal techniques. Subsequently, the image quality was compared. The reconstructed images indicated the stent deployment degree and packing density. Follow-up assessments included clinical and angiographic outcomes and complications.
RESULTS: In total, 118 aneurysms were successfully embolized using 118 stents. Image quality was significantly higher (P < .05) with high-resolution C-arm CT combined with streak metal artifact removal reconstruction. Streak metal artifact removal reconstruction and 2D angiography at working angles showed incomplete deployment of 6 stents and incomplete aneurysm embolization of 15 patients, which were subsequently resolved. One case of hemorrhage was noted postoperatively. Follow-up of 93 patients at 6-13 months indicated 3 cases of aneurysm recurrence.
CONCLUSIONS: High-resolution C-arm CT combined with the streak metal artifact removal technique effectively reduced metal artifacts from stents and coils during aneurysm embolization. This method can help physicians determine the extent of stent deployment and the packing density of coils and thus potentially reduce complications and aneurysm recurrence.
© 2019 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31558505     DOI: 10.3174/ajnr.A6190

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  4 in total

1.  Intraoperative cone beam computed tomography of tracheal stenting for stenosis and fistula diseases: a retrospective cohort study.

Authors:  Jing Li; Kaihao Xu; Zhaonan Li; Yahua Li; Xueliang Zhou; Juanfang Liu; Yuan Yao; Zaoqu Liu; De-Chao Jiao; Xinwei Han
Journal:  Quant Imaging Med Surg       Date:  2022-05

2.  Intraoperative cone-beam CT with metal artifact reduction for assessment of the electrode position and the intracranial structures during deep brain stimulation procedure.

Authors:  Toshinari Kawasaki; Takayuki Kikuchi; Katharina Otani; Yuto Mitsuno; Yukihiro Yamao; Nobukatsu Sawamoto; Ryosuke Takahashi; Susumu Miyamoto
Journal:  Acta Neurochir (Wien)       Date:  2022-07-18       Impact factor: 2.816

3.  Efficacy of 3D-Printed Titanium Mesh-Type Patient-Specific Implant for Cranioplasty.

Authors:  Hong-Gyu Yoon; Yong Ko; Young-Soo Kim; Koang-Hum Bak; Hyoung-Joon Chun; Min-Kyun Na; Sook Yang; Hyeong-Joong Yi; Kyu-Sun Choi
Journal:  Korean J Neurotrauma       Date:  2021-09-09

4.  Application of High-Resolution Flat Detector Computed Tomography in Stent Implantation for Intracranial Atherosclerotic Stenosis.

Authors:  Tengfei Li; Yuting Wang; Ji Ma; Michael Levitt; Mahmud Mossa-Basha; Chengcheng Shi; Yuncai Ran; Jianzhuang Ren; Xinwei Han; Chengcheng Zhu
Journal:  Front Neurosci       Date:  2021-08-27       Impact factor: 4.677

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.