| Literature DB >> 35493403 |
Muhammad Waqar Mirza1, Asif Siddiq1, Ishtiaq Rasool Khan2.
Abstract
Medical imaging can help doctors in better diagnosis of several conditions. During the present COVID-19 pandemic, timely detection of novel coronavirus is crucial, which can help in curing the disease at an early stage. Image enhancement techniques can improve the visual appearance of COVID-19 CT scans and speed-up the process of diagnosis. In this study, we analyze some state-of-the-art image enhancement techniques for their suitability in enhancing the CT scans of COVID-19 patients. Six quantitative metrics, Entropy, SSIM, AMBE, PSNR, EME, and EMEE, are used to evaluate the enhanced images. Two experienced radiologists were involved in the study to evaluate the performance of the enhancement techniques and the quantitative metrics used to assess them.Entities:
Keywords: COVID-19; CT; Coronavirus; Histogram equalization; Medical image enhancement; Medical image quality assessment
Year: 2022 PMID: 35493403 PMCID: PMC9037579 DOI: 10.1007/s11760-022-02214-2
Source DB: PubMed Journal: Signal Image Video Process ISSN: 1863-1703 Impact factor: 1.583
Performance of the histogram-based enhancement techniques on existing medical image datasets
| Methods | Dataset | Scores of quantitative metrics |
|---|---|---|
| BBHE | CT [ | PSNR: [18.1,19]; SSIM: [0.24, 0.3]; EMEE: [0.15, 0.16] |
| DSIHE | CT [ | PSNR: [29,33.9]; SSIM: [0.88,0.9]; EMEE: [0.56,0.67] |
| MMBEBHE | MRI [ | E: [2.7,6.2]; *AMBE: [7.2,17.7]; PSNR: [18.2,22.7]; SSIM: [0.2,0.85]; FSIM: [0.97,0.99]; *NIQE: [4.1,8.2] |
| RMSHE | Mammogram [ | EME: [3.8,7.2]; PSNR: [15.6,34.4]; *MSE: [49.2,116.8]; AMBE: [2.8,17.2] |
| RSIHE | CT [ | E: [3.5,4.75]; PSNR: [19.6,26.8]; SSIM: [0.69,0.83] |
| RSWHE | MRI [ | DE: [3.9,5]; *NIQE: [7.7,13.2] |
| AGCWD | CT [ | PSNR: [18.4,20.6]; SSIM: [0.94,0.97]; EMEE: [2.5,3.0] |
| ESIHE | MRI and retinal fundus [ | E: [5.5,6.3]; PSNR: [23.5,29.5]; CII: [0.75,3.6]; MC: 0.46; WC: 0.57; EME: 6.85; EMEE: 0.025 |
| R-ESIHE | X-ray [ | E: [6.15,7.4]; CII: [0.88,1.3] |
| RS-ESIHE | MRI [ | E: [5.0,5.7]; PSNR: [24.2,24.5]; Contrast: [0.16,0.41]; *AMBE: [44.7,63.53]; EME: [1.4,3.2]; SSIM: [0.3,0.52]; FSIM: [0.75,0.93] |
| BHE | X-ray images [ | TMQI-S: [0.76,0.90]; Entropy: [6.9,7.78] |
| cl-BHE | X-ray [ | TMQI-S: [0.6,0.93]; Entropy: [6.1,7.84] |
| NLQ | CT [ | Visual Assessment Median scores: [7.3,8.83] |
The range of reported scores on the used datasets is mentioned in the [min, max] notation. If only one value is given, it indicates the average score on the entire dataset. The works from where these results are taken are cited in the second column. In general, a high score indicates a better quality, except for the metrics marked with an asterisk which assign low score for better quality
Fig. 1Experimental results of different Image enhancement techniques a BBHE b DSIHE c MMBEBHE d RMSHE e RSIHE f RSWHE g AGCWD h ESIHE i R-ESIHE j RS-ESIHE k BHE l cl-BHE m PQ n NLQ
Average scored of 50 enhanced images assigned by the quality assessment metrics
| Technique | Metric | |||||
|---|---|---|---|---|---|---|
| Entropy | EME | EMEE | SSIM | AMBE | PSNR | |
| Original image | 11.22837 | 5.160185 | – | – | – | |
| (a) BBHE | 5.081202 | 31.94168 | 9.457133 | 0.504142 | 33.98483 | 13.26234 |
| (b) DSIHE | 5.106667 | 42.2347 | 20.21942 | 0.454603 | 45.05604 | 11.38862 |
| (c) MMBEBHE | 5.084623 | 37.13259 | 13.71136 | 0.531044 | 39.00554 | 12.25849 |
| (d) RMSHE | 4.402703 | 35.90697 | 12.97667 | |||
| (e) RSIHE | 4.464937 | 40.56246 | 18.53984 | 0.87376 | 3.770466 | 28.54897 |
| (f) RSWHE | 4.901565 | 21.11102 | 4.962463 | 0.168555 | 115.4839 | 6.29218 |
| (g) AGCWD | 5.343632 | 50.06877 | 46.56809 | 0.613889 | 38.0514 | 12.79779 |
| (h) ESIHE | 5.323192 | 41.15775 | 19.51397 | 0.497917 | 38.97651 | 13.48288 |
| (i) R-ESIHE | 5.308788 | 44.54052 | 26.12391 | 0.560577 | 36.72041 | 13.35319 |
| (j) RS-ESIHE | 5.189115 | 21.03791 | 5.05397 | 0.263516 | 78.87339 | 9.991406 |
| (k) BHE | 0.195851 | 85.70393 | 7.998395 | |||
| (l) cl-BHE | 6.948765 | 56.46655 | 62.53966 | 0.303929 | 59.87531 | 11.20919 |
| (m) TMO-PQ | 7.067735 | 5.901825 | 1.564038 | 0.24605 | 81.40261 | 8.534669 |
| (n) NLQ | 6.74173 | 53.64712 | 52.18378 | 0.416907 | 43.25627 | 13.17442 |
Bold values indicate the best values among the image quality assessment metrics
The techniques’ ranks determined based on the evaluations by the radiologist and average scores assigned by six quality assessment metrics
| Enhancement Methods | Visual Assessment by Radiologists | Ranks based on Quantitative Assessment | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Scores | Rank | Entropy | EME | EMEE | SSIM | AMBE | PSNR | Total | Overall Rank | |
| (a) BBHE | 3 | 11 | 11 | 11 | 6 | 3 | 5 | 47 | ||
| (b) DSIHE | 15 | 9 | 6 | 6 | 8 | 9 | 9 | 47 | ||
| (c) MMBEBHE | 12 | 10 | 9 | 9 | 5 | 7 | 8 | 48 | ||
| (d) RMSHE | 11 | 14 | 10 | 10 | 1 | 1 | 1 | 37 | ||
| (e) RSIHE | 7 | 13 | 8 | 8 | 2 | 2 | 2 | 35 | ||
| (f) RSWHE | 11 | 12 | 12 | 13 | 14 | 14 | 14 | 79 | ||
| (g) AGCWD | 20 | 5 | 4 | 4 | 3 | 5 | 7 | 28 | ||
| (h) ESIHE | 10 | 6 | 7 | 7 | 7 | 6 | 3 | 36 | ||
| (i) R-ESIHE | 21 | 7 | 5 | 5 | 4 | 4 | 4 | 29 | ||
| (j) RS-ESIHE | 6 | 8 | 13 | 12 | 11 | 11 | 11 | 66 | ||
| (k) BHE | 1 | 1 | 1 | 1 | 13 | 13 | 13 | 42 | ||
| (l) cl-BHE | 7 | 3 | 2 | 2 | 10 | 10 | 10 | 37 | ||
| (m) TMO-PQ | 11 | 2 | 14 | 14 | 12 | 12 | 12 | 71 | ||
| (n) NLQ | 15 | 4 | 3 | 3 | 9 | 8 | 6 | 33 | ||
Bold values indicate the ranks attained by each technique from quantitative and subjective evaluation scores
Overall SRCC Values of metrics
| Metric | Entropy | EME | EMEE | SSIM | AMBE | PSNR | Combined |
|---|---|---|---|---|---|---|---|
| SRCC | 0.038 | 0.128 | 0.108 | 0.358 | 0.212 | 0.226 | 0.409 |
Eight techniques that made to top-5 in radiologist’s opinion and their rankings by the metrics
| i | g | b | n | c | d | f | m | SRCC | |
|---|---|---|---|---|---|---|---|---|---|
| R | 1 | 2 | 3 | 3 | 4 | 5 | 5 | 5 | 0.815 |
| M | 2 | 1 | 8 | 3 | 9 | 6 | 12 | 11 |
Five best techniques determined by the combined scored of six metrics and their rankings by the radiologist
| Technique | g | i | n | e | h | SRCC |
|---|---|---|---|---|---|---|
| M | 1 | 2 | 3 | 4 | 5 | 0.855 |
| R | 2 | 1 | 3 | 7 | 6 |