Literature DB >> 12034958

Chest CT window settings with multiscale adaptive histogram equalization: pilot study.

Laura M Fayad1, Yinpeng Jin, Andrew F Laine, Yahya M Berkmen, Gregory D Pearson, Benjamin Freedman, Ronald Van Heertum.   

Abstract

Multiscale adaptive histogram equalization (MAHE), a wavelet-based algorithm, was investigated as a method of automatic simultaneous display of the full dynamic contrast range of a computed tomographic image. Interpretation times were significantly lower for MAHE-enhanced images compared with those for conventionally displayed images. Diagnostic accuracy, however, was insufficient in this pilot study to allow recommendation of MAHE as a replacement for conventional window display.

Entities:  

Mesh:

Year:  2002        PMID: 12034958     DOI: 10.1148/radiol.2233010943

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

Review 1.  Fusion viewer: a new tool for fusion and visualization of multimodal medical data sets.

Authors:  Karl G Baum; María Helguera; Andrzej Krol
Journal:  J Digit Imaging       Date:  2007-10-25       Impact factor: 4.056

2.  The importance of surrounding tissues and window settings for contouring of moving targets.

Authors:  Kai Joachim Borm; Markus Oechsner; Johannes Berndt; Stephanie Elisabeth Combs; Michael Molls; Marciana Nona Duma
Journal:  Strahlenther Onkol       Date:  2015-06-19       Impact factor: 3.621

3.  Clinical Applications of a CT Window Blending Algorithm: RADIO (Relative Attenuation-Dependent Image Overlay).

Authors:  Jacob C Mandell; Bharti Khurana; Les R Folio; Hyewon Hyun; Stacy E Smith; Ruth M Dunne; Katherine P Andriole
Journal:  J Digit Imaging       Date:  2017-06       Impact factor: 4.056

4.  Enhanced gray-white matter differentiation on non-enhanced CT using a frequency selective non-linear blending.

Authors:  Georg Bier; Malte Niklas Bongers; Hendrik Ditt; Benjamin Bender; Ulrike Ernemann; Marius Horger
Journal:  Neuroradiology       Date:  2016-03-10       Impact factor: 2.804

5.  Computed tomography window blending in maxillofacial imaging.

Authors:  Nityanand Miskin; M Travis Caton; Jeffrey P Guenette; Jacob C Mandell
Journal:  Emerg Radiol       Date:  2019-11-12

6.  A comparative study of medical image enhancement algorithms and quality assessment metrics on COVID-19 CT images.

Authors:  Muhammad Waqar Mirza; Asif Siddiq; Ishtiaq Rasool Khan
Journal:  Signal Image Video Process       Date:  2022-04-25       Impact factor: 1.583

7.  Lesion measurement on a combined "all-in-one" window for chest CT: effect on intra- and interobserver variability.

Authors:  Annemiek Snoeckx; Jeroen Cant; Caro Franck; Elisa Luyckx; Ken Carpentier; Simon Nicolay; Astrid Van Hoyweghen; Maarten J Spinhoven; Pieter Vuylsteke; Paul M Parizel
Journal:  Cancer Imaging       Date:  2019-11-29       Impact factor: 3.909

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.