Automatic external defibrillators used by emergency medical technicians. A controlled clinical trial.

R O Cummins, M S Eisenberg, P E Litwin, J R Graves, T R Hearne, A P Hallstrom.   

Abstract

In a randomized controlled clinical trial, the effectiveness of emergency medical technician (EMT) use of automatic external defibrillators (AEDs) was compared with EMT use of standard defibrillators for patients in cardiac arrest. A total of 321 cardiac arrest patients were treated during the study: 116 were treated by EMTs using the AED (AUTO group), 158 were treated by EMTs using the standard defibrillators (standard group), and 47 were treated by EMTs using the standard defibrillator when they were assigned to use the AED. There was no significant differences in hospital admission or discharge rates between the AUTO group (54% admitted, 28% discharged) and the standard group (52% admitted, 23% discharged) for patients in ventricular fibrillation (VF), for patients in non-VF rhythms, or for all patients combined. The only significant difference observed was in the time from power ON to first shock: 1.1 minutes average AUTO group and 2.0 minutes average standard group. The treatment groups did not differ significantly in sensitivity for VF (78% AED, 76% standard), specificity for non-VF rhythms (100% AED, 95% standard), or rates of defibrillation to a non-VF rhythm (62% AED, 57% standard). We conclude that in clinical outcomes and device performance, AEDs are comparable with standard defibrillators and should be considered an acceptable alternative. Automatic external defibrillators appear to have advantages over standard defibrillators in training, skill retention, and faster operation. Such devices can make early defibrillation available for a much larger portion of the population. They are a major innovation for the prehospital care of cardiac arrest patients.

Entities:  

Mesh:

Year:  1987        PMID: 3546751

Source DB:  PubMed          Journal:  JAMA        ISSN: 0098-7484            Impact factor:   56.272


  14 in total

1.  Management of the critically injured football player.

Authors:  F Feld
Journal:  J Athl Train       Date:  1993       Impact factor: 2.860

2.  "Heartstart Scotland"--initial experience of a national scheme for out of hospital defibrillation.

Authors:  S M Cobbe; M J Redmond; J M Watson; J Hollingworth; D J Carrington
Journal:  BMJ       Date:  1991-06-22

3.  Emergency medicine: expanding the use of automatic external defibrillators to home and community.

Authors:  R O Cummins
Journal:  West J Med       Date:  1987-05

4.  Flying Squad response to medical emergencies.

Authors:  D Barton; P Pritty
Journal:  Arch Emerg Med       Date:  1990-03

5.  Defibrillation by ambulance staff.

Authors: 
Journal:  BMJ       Date:  1989-08-12

Review 6.  Is prehospital advanced life support really necessary?

Authors:  M R de la Roche
Journal:  CMAJ       Date:  1987-12-01       Impact factor: 8.262

7.  Automated external defibrillation.

Authors:  M C Colquhoun
Journal:  Br J Gen Pract       Date:  1993-03       Impact factor: 5.386

8.  Effect of reducing ambulance response times on deaths from out of hospital cardiac arrest: cohort study.

Authors:  J P Pell; J M Sirel; A K Marsden; I Ford; S M Cobbe
Journal:  BMJ       Date:  2001-06-09

9.  Sudden Cardiac Arrest in Athletic Medicine.

Authors:  Glenn C. Terry; James M. Kyle; James M. Ellis; John Cantwell; Ron Courson; Ron Medlin
Journal:  J Athl Train       Date:  2001-06       Impact factor: 2.860

10.  Mortality within hospital after resuscitation from ventricular fibrillation outside hospital.

Authors:  W Dickey; A A Adgey
Journal:  Br Heart J       Date:  1992-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.