Literature DB >> 35463101

Clarke Error Grid Analysis for Performance Evaluation of Glucometers in a Tertiary Care Referral Hospital.

Sohini Sengupta1, Anil Handoo2, Inaamul Haq3, Karamvir Dahiya4, Sanjay Mehta5, Mradul Kaushik6.   

Abstract

Glucometer is the most commonly used POCT device and guides monitoring of blood glucose level in both clinical settings and outside. Inaccurate glucometer readings resulting in erroneous therapeutic intervention has critical consequences on patient care. Regulatory guidelines for performance evaluation of glucometers are not available in many countries. A robust program implemented by the hospital is essential to ensure accuracy and precision of glucometers to produce optimal results. The objective of this study was to design a quality assurance program for the evaluation of glucometers in a high volume tertiary care referral hospital and evaluate the results from July'18 to July'19. Seventy three glucometers used across the hospital were subjected to Internal Quality Control checks and Proficiency Testing performed once a month and every 3 months respectively. The results were reviewed and plotted on a Bland Altman Graph. Clarke Error Grid Analysis was done to evaluate the clinical significance of inaccuracies in the measurement of blood glucose concentration as per ISO 15197: 2013. Eight devices were identified as unacceptable by ISO standards and replaced subsequently. 96.83% and 3.17% of the values were in Zone A and B of Clarke Error Grid Analysis. The study complied with the standard which requires that 99% of the values fall within zones A and B. The review of the program after one year and its ability to identify defective glucometers has validated the efficacy of the model. The method used may be suggested as a prototype for quality management of glucometers in a clinical setting. © Association of Clinical Biochemists of India 2021.

Entities:  

Keywords:  Glucometer; Internal quality control (IQC); Point-of-care-testing (POCT); Proficiency testing (PT)

Year:  2021        PMID: 35463101      PMCID: PMC8993970          DOI: 10.1007/s12291-021-00971-4

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  14 in total

1.  Tests of glycemia in diabetes.

Authors:  David E Goldstein; Randie R Little; Rodney A Lorenz; John I Malone; David M Nathan; Charles M Peterson
Journal:  Diabetes Care       Date:  2003-01       Impact factor: 19.112

2.  Variability of blood glucose concentration and short-term mortality in critically ill patients.

Authors:  Moritoki Egi; Rinaldo Bellomo; Edward Stachowski; Craig J French; Graeme Hart
Journal:  Anesthesiology       Date:  2006-08       Impact factor: 7.892

3.  Reducing Treatment Errors Through Point-of-Care Glucometer Configuration.

Authors:  Jamie L Estock; Ivan-Thibault Pham; Holly K Curinga; Benjamin J Sprague; Monique Y Boudreaux-Kelly; Jeanette Acevedo; Katrina Jacobs
Journal:  Jt Comm J Qual Patient Saf       Date:  2018-07-09

4.  [Clinical testing of a new blood glucose measuring system. A cooperative study at 8 centers].

Authors:  C Rosak; N Lotz; W Bachmann; F A Gries; P Hürter; W Kerner; T Koschinsky; F Lacher; H Mehnert; H Otto
Journal:  Dtsch Med Wochenschr       Date:  1987-03-20       Impact factor: 0.628

Review 5.  Glucose meters: a review of technical challenges to obtaining accurate results.

Authors:  Ksenia Tonyushkina; James H Nichols
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

6.  Glucometers-need for external quality control.

Authors:  D Suhasini
Journal:  Indian J Clin Biochem       Date:  2000-07

Review 7.  Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review.

Authors:  Shigeaki Inoue; Moritoki Egi; Joji Kotani; Kiyoshi Morita
Journal:  Crit Care       Date:  2013-03-18       Impact factor: 9.097

Review 8.  Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults.

Authors:  Simon Finfer; Jan Wernerman; Jean-Charles Preiser; Tony Cass; Thomas Desaive; Roman Hovorka; Jeffrey I Joseph; Mikhail Kosiborod; James Krinsley; Iain Mackenzie; Dieter Mesotten; Marcus J Schultz; Mitchell G Scott; Robbert Slingerland; Greet Van den Berghe; Tom Van Herpe
Journal:  Crit Care       Date:  2013-06-14       Impact factor: 9.097

9.  Diabetic status and the relation of the three domains of glycemic control to mortality in critically ill patients: an international multicenter cohort study.

Authors:  James S Krinsley; Moritoki Egi; Alex Kiss; Amin N Devendra; Philipp Schuetz; Paula M Maurer; Marcus J Schultz; Roosmarijn T M van Hooijdonk; Morita Kiyoshi; Iain M J Mackenzie; Djillali Annane; Peter Stow; Stanley A Nasraway; Sharon Holewinski; Ulrike Holzinger; Jean-Charles Preiser; Jean-Louis Vincent; Rinaldo Bellomo
Journal:  Crit Care       Date:  2013-03-01       Impact factor: 9.097

10.  A model for managing and monitoring the quality of glucometers used in a high-volume clinical setting.

Authors:  Güzin Aykal; Ayşenur Yegin; Özgür Tekeli; Necat Yilmaz
Journal:  Biochem Med (Zagreb)       Date:  2016       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.