Literature DB >> 35443046

CAN THE SIZE-SPECIFIC DOSE ESTIMATE BE DERIVED FROM THE BODY MASS INDEX? A FEASIBILITY STUDY.

Beatrice Steiniger1, Chris Klippel1, Ulf Teichgräber1, Jürgen R Reichenbach2, Martin Fiebich3.   

Abstract

Size-specific dose estimate ($\mathbf{SSDE}$) index appears to be more suitable than the commonly used volume computed tomography dose index ($\mathbf{C}{\mathbf{TDI}}_{\mathbf{vol}}$) to estimate the dose delivered to the patient during a computed tomography (CT) scan. We evaluated whether an ${\mathbf{SSDE}}_{\mathbf{BMI}}$ can be determined from the patient's body mass index ($\mathbf{BMI}$) with sufficient reliability in the case that a $\mathbf{SSDE}$ is not given by the CT scanner. For each of the three most used examination types, CT examinations of 50 female and 50 male patients were analyzed. The $\mathbf{SSDE}$ values automatically provided by the scanner were compared with ${\mathbf{SSDE}}_{\mathbf{BMI}}$ determined from $\mathbf{C}{\mathbf{TDI}}_{\mathbf{vol}}$ and $\mathbf{BMI}$. A good accordance of ${\mathbf{SSDE}}_{\mathbf{BMI}}$ and $\mathbf{SSDE}$ was found for the chest and abdominal regions. A low correlation was observed for the head region. The presented method is a simple and practically useful surrogate approach for the chest and abdominal regions but not for the head.
© The Author(s) 2022. Published by Oxford University Press.

Entities:  

Mesh:

Year:  2022        PMID: 35443046      PMCID: PMC9113340          DOI: 10.1093/rpd/ncac038

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.954


  20 in total

1.  A comparison study of size-specific dose estimate calculation methods.

Authors:  Roshni A Parikh; Michael A Wien; Ronald D Novak; David W Jordan; Paul Klahr; Stephanie Soriano; Leslie Ciancibello; Sheila C Berlin
Journal:  Pediatr Radiol       Date:  2017-09-27

2.  Comparison of different body size parameters for individual dose adaptation in body CT of adults.

Authors:  Jan Menke
Journal:  Radiology       Date:  2005-08       Impact factor: 11.105

3.  Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinations.

Authors:  Babak Alikhani; Tobias Getzin; Till Frederik Kaireit; Kristina Imeen Ringe; Leila Jamali; Frank Wacker; Thomas Werncke; Hans-Jürgen Raatschen
Journal:  Eur J Radiol       Date:  2018-01-31       Impact factor: 3.528

4.  PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS.

Authors:  Ali Mehdipour; Masoumeh Parsi; Faezeh-Sadat Khorram
Journal:  Radiat Prot Dosimetry       Date:  2019-12-23       Impact factor: 0.972

5.  ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY.

Authors:  Johannes Boos; Patric Kröpil; Oliver Th Bethge; Joel Aissa; Christoph Schleich; Lino Morris Sawicki; Niklas Heinzler; Gerald Antoch; Christoph Thomas
Journal:  Radiat Prot Dosimetry       Date:  2018-01-01       Impact factor: 0.972

6.  The influence of patient centering on CT dose and image noise.

Authors:  Thomas Toth; Zhanyu Ge; Michael P Daly
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

7.  Body composition changes in stable-weight elderly subjects: the effect of sex.

Authors:  Mauro Zamboni; Elena Zoico; Tiziana Scartezzini; Gloria Mazzali; Paolo Tosoni; Alessandra Zivelonghi; Dympna Gallagher; Giovanni De Pergola; Vincenzo Di Francesco; Ottavio Bosello
Journal:  Aging Clin Exp Res       Date:  2003-08       Impact factor: 3.636

8.  Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT: The Report of AAPM Task Group 220.

Authors:  Cynthia McCollough; Donovan M Bakalyar; Maryam Bostani; Samuel Brady; Kristen Boedeker; John M Boone; H Heather Chen-Mayer; Olav I Christianson; Shuai Leng; Baojun Li; Michael F McNitt-Gray; Roy A Nilsen; Mark P Supanich; Jia Wang
Journal:  AAPM Rep       Date:  2014-09

9.  Using body mass index to estimate individualised patient radiation dose in abdominal computed tomography.

Authors:  Siobhan O'Neill; Richard G Kavanagh; Brian W Carey; Niamh Moore; Michael Maher; Owen J O'Connor
Journal:  Eur Radiol Exp       Date:  2018-11-28

10.  An improved method for automated calculation of the water-equivalent diameter for estimating size-specific dose in CT.

Authors:  Choirul Anam; Fahmi Rosydiansyah Mahdani; Winda Kusuma Dewi; Heri Sutanto; Pandji Triadyaksa; Freddy Haryanto; Geoff Dougherty
Journal:  J Appl Clin Med Phys       Date:  2021-07-22       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.