Sandris Petronis1,2, Ruta Jakusonoka1, Viktors Linovs3, Andris Jumtins1. 1. Department of Orthopaedics, Riga Stradins University, Riga, Latvia. 2. Department of Orthopaedics, Riga Second Hospital, Riga, Latvia. 3. Department of Radiology, Riga Second Hospital, Riga, Latvia.
The biphasic calcium phosphate ceramic granules with hydroxyapatite/β-tricalcium phosphate in selected ratio of 90/10 is a new method and can be used for filling severe bone defects.
Introduction
With the increasing number of primary total hip replacements, a substantial increase in the number of revision operations is to be expected [1, 2]. There is a growing number of patients who require a first or even repeated revision surgery and this surgery is often complex and technically demanding [3]. During arthroplasty revision, bone defects should be filled. With femoral bone defects, there are no metal augmentations for filling these defects. The periprosthetic fractures with bone defects can occur during removal of the femoral component and healing of these fractures can be delayed. Bone in-growth in the non-cemented hip arthroplasty femoral component after arthroplasty revisions is not evenly distributed throughout the entire porous surface [4]. Bone autografts, allografts and synthetic bone substitutes are widely used for orthopedic clinical applications [5]. Mesenchymal stromal cells combined with β-tricalcium phosphate (β-TCP) scaffold are used for femoral bone defects [6].We developed a method for filling femoral bone defects in non-cemented hip arthroplasty revisions and periprosthetic fractures, producing biphasic calcium phosphate (BCP) ceramic granules with hydroxyapatite/β-TCP (HAp/β-TCP) in selected ratio of 90/10, because minor amount of β-TCP due to the faster resorption rate compared to HAp is supposed to burst of releasing calcium and phosphate ions into biological medium, thus contributing new bone formation. The majority of HAp remaining after resorption of β-TCP acts as a tissue scaffold for the complete formation of new bone [7, 8].Here, we present a case of filling of bone defects in arthroplasty revisions following periprosthetic fracture and with 8-year follow-up and result of treatment.
Case Report
A 59-year-old female was admitted to the hospital with increasing pain in the left hip joint 5 years following non-cemented total hip arthroplasty because of osteoarthritis of left hip joint. She was admitted to the same hospital where she received initial diagnosis and treatment. Clinically, she presented with a fistula on the lateral aspect of the hip. The radiographs done prior to the operation showed a non-cemented total hip arthroplasty implant. The acetabular component was fixed with additional fixation with a screw. The femoral component was located centrally in the femoral shaft. There was severe femoral bone loss involving the proximal part of diaphysis and there was >4 cm of intact diaphyseal bone available for distal fixation – Paprosky Type III A. Fistulography was performed and the connection of the fistula with femoral shaft was visualized (Fig. 1a, b).
Figure 1
(a and b) Radiograph (anteroposterior view) of the left hip of a 59-year-old female with noncemented endoprosthesis. Osteolytic zone (red dashed line) around the acetabular component, with a small osteolytic zone around the proximal part of the femoral component and severe femoral bone loss involving the proximal part of diaphysis (green dashed line). The connection of the fistula with the femoral shaft is seen in the radiograph.
(a and b) Radiograph (anteroposterior view) of the left hip of a 59-year-old female with noncemented endoprosthesis. Osteolytic zone (red dashed line) around the acetabular component, with a small osteolytic zone around the proximal part of the femoral component and severe femoral bone loss involving the proximal part of diaphysis (green dashed line). The connection of the fistula with the femoral shaft is seen in the radiograph.The surgical approach was performed at the site of the previous operation scar. The fistula was excised and tissue sent for microbiological examination. Granulation tissue was excised from the hip joint. Signs of inflammation were seen in the posterior part of the acetabular roof. The acetabular component was slightly mobile. Granulation tissue and discharge were found in the proximal part of the femur. The decision to remove the endoprosthesis was taken. An osteotomy of the proximal part of the femur was performed. The stem was firmly fixed in the proximal part of the femur, which was osteoporotic. During removal of the stem two fractures occurred in the area of osteotomy – one in the proximal part of femoral diaphysis just below the major trochanter, and the other was a horizontal fracture about 5.3 cm distally to the previous fracture. Then the acetabular part of endoprosthesis and screws were removed. A fracture occurred in the posterior wall of the acetabulum. Necrotic tissue was excised. The acetabulum was washed with saline and chlorhexidine solution. Fractures were fixed with two cerclage wires in the trochanteric region and two in the proximal diaphysis region. BCP ceramic granules with HAp/β-TCP 10 g (ratio of 90/10) were used to fill the femoral bone at the fracture sites. Antibiotic treatment and low-molecular-weight heparin were used post-operatively.Radiographs after operation showed the situation after the hip implant removal. There were multiple fractures of the proximal part of the femoral diaphysis as well as a trochanter major fracture and displacement of a distally located fracture with dorsal angulation of distal fragment by about 33°. An extensive combined-type bone defect was seen on the posterior and lateral aspects of the femoral diaphysis (Gruen zones 2 and 13 with large cavitary defect) with segmental defects, and the defect size was approximately 79 × 5 × 5 mm. The defect was fully filled with BCP ceramic granules, and the granules were also seen in the soft tissues surrounding the defect without any signs of osseous integration. The quality of the packaging of the granules is described as good. The tissue zone occupied by granules was about 136 × 28 × 25 mm (Gruen zones 2, 3, 12, 13) (Fig. 2).
Figure 2
(a and b) Post-operative radiograph of the left hip after endoprosthesis removal. Multiple fractures (red dashed line) of proximal part of the femoral diaphysis as well as a trochanter major fracture. Extensive combined type bone defect is seen on the lateral aspect of the femoral diaphysis (Gruen zones 2 and 13 with large cavitary defect – green dashed line) and segmental defects (red zones) defect size is approximately 79 × 5 × 5 mm. The defect is fully filled with biphasic calcium phosphate granules and granules are also visualized in the soft tissues surrounding the defect without any signs of osseous integration. The packaging of the granules is described as of good quality. The tissue zone that is occupied by granules is 136 × 28 × 25 mm (Gruen zones 2, 3, 12, 13 – red zone filled with lines).
(a and b) Post-operative radiograph of the left hip after endoprosthesis removal. Multiple fractures (red dashed line) of proximal part of the femoral diaphysis as well as a trochanter major fracture. Extensive combined type bone defect is seen on the lateral aspect of the femoral diaphysis (Gruen zones 2 and 13 with large cavitary defect – green dashed line) and segmental defects (red zones) defect size is approximately 79 × 5 × 5 mm. The defect is fully filled with biphasic calcium phosphate granules and granules are also visualized in the soft tissues surrounding the defect without any signs of osseous integration. The packaging of the granules is described as of good quality. The tissue zone that is occupied by granules is 136 × 28 × 25 mm (Gruen zones 2, 3, 12, 13 – red zone filled with lines).Two months after the removal of endoprosthesis, re-implantation of the non-cemented endoprosthesis was performed. The patient was given spinal anesthesia and placed on a radiolucent operating table in lateral position. A longitudinal incision was performed 20 cm. An acetabulum implant was inserted. Then the femoral non-cemented implant was inserted. BCP ceramic granules with HAp/β-TCP 20 g (ratio of 90/10) were implanted in the bone defect. Gentamycin was added.Antibiotic prophylaxis was given for 7-8 days and low-molecular-weight heparin was used to prevent thromboembolic disease. Post-operative physiotherapy was begun on the 1st day after operation, and partial weight-bearing (20%) was started on post-operative day 1, and full weight-bearing was started 12 weeks after surgery.Radiographs after operation showed the non-cemented acetabulum implant and the femoral non-cemented implant. The proximally located fracture of the femur could not be differentiated, and the distally located fracture was partially healed. The BCP granule-filled zone was more attenuated compared with the previous examination with signs of trabecular incorporation (Gruen zones 2 and 13) in other zones where the granules are visualized without signs of integration (Fig. 3).
Figure 3
Postoperative radiographs of the left hip revision arthroplasty, non- cemented acetabulum implant with additional fixation with two screws and the femoral non-cemented implant with long stem fixed with two interlocking screws in the distal part of the stem and the additional fixation of the proximal part of the femoral implant with cerclage. There are two additional cerclage wires projected in the middle part of the femoral implant stem compared to the previous examination.
Postoperative radiographs of the left hip revision arthroplasty, non- cemented acetabulum implant with additional fixation with two screws and the femoral non-cemented implant with long stem fixed with two interlocking screws in the distal part of the stem and the additional fixation of the proximal part of the femoral implant with cerclage. There are two additional cerclage wires projected in the middle part of the femoral implant stem compared to the previous examination.The patient underwent follow-up. Clinical and radiographic examinations of the patient were scheduled 1 day before surgery, then 6 weeks, and 3, 6, 9, and 12 months following surgery.Eleven months following the revision of the arthroplasty, the patient was admitted in the same hospital by ambulance after falling on the street with severe pain in the left femur. Radiograph of the left femur showed a periprosthetic fracture of the distal third of the femur (Fig. 4a, b).
Figure 4
(a and b) Radiographs of the left femur with periprosthetic fracture 11 months after revision arthroplasty. Periprosthetic fracture of the distal third of the femur with lateral displacement of about the width of the cortical thickness of the femur and dorsal displacement of about one third of the cortical thickness.
(a and b) Radiographs of the left femur with periprosthetic fracture 11 months after revision arthroplasty. Periprosthetic fracture of the distal third of the femur with lateral displacement of about the width of the cortical thickness of the femur and dorsal displacement of about one third of the cortical thickness.Osteosynthesis of periprosthetic fracture lateral plate and two cerclage wires was performed and BCP granules with HAp/β-TCP 15 g (ratio of 90/10) were used to fill the bone defect (Fig. 5).
Figure 5
Postoperative radiographs of the left femur periprosthetic fracture after distal femoral fracture fixation with lateral plate, two additional screws and two cerclages.
Postoperative radiographs of the left femur periprosthetic fracture after distal femoral fracture fixation with lateral plate, two additional screws and two cerclages.The patient underwent long-term follow-up. Clinical and radiographic examinations of all patients were scheduled at 3, 6, 9, and 12 months, 4 and 6 years follow up.In the 6-year follow-up exam, a functional result evaluation, using the Merle d’Aubigné Hip Score was performed (pain – maid and inconsistent, normal activity -5 grades; mobility – flexion extends 90°, abduction of 30° - 6 grades; ability to work – without cane, and slight limp – 5 grades). Clinical grades given by the pain scores and mobility results as absolute results for hip function – 11 grades, very good. In the radiograph HAp of the transplant at lateral side of femur proximally and distally is seen (Fig. 6a, b).
Figure 6
(a and b) Control radiographs at 6 years follow-up of femur of the left hip and femur showing transplanted hydroxyapatite at the lateral side of the femur proximally and distally. Radiograph shows a non-cemented acetabulum implant with additional fixation with two screws and the femoral non-cemented implant with long stem with two interlocking screws in the distal part of the stem and the additional fixation of the proximal part of the femoral implant with cerclage. Distal femur fixation with lateral plate, screws, and two cerclages. Previous fracture lines cannot be differentiated – full consolidation. The biphasic calcium phosphate granule-filled zone is more attenuated compared with the previous examinations cortical repair and trabecular incorporation (Gruen zones 2, 3, 12, 13). There is a small fraction of the granules located in the soft tissues that were not incorporated into the bone.
(a and b) Control radiographs at 6 years follow-up of femur of the left hip and femur showing transplanted hydroxyapatite at the lateral side of the femur proximally and distally. Radiograph shows a non-cemented acetabulum implant with additional fixation with two screws and the femoral non-cemented implant with long stem with two interlocking screws in the distal part of the stem and the additional fixation of the proximal part of the femoral implant with cerclage. Distal femur fixation with lateral plate, screws, and two cerclages. Previous fracture lines cannot be differentiated – full consolidation. The biphasic calcium phosphate granule-filled zone is more attenuated compared with the previous examinations cortical repair and trabecular incorporation (Gruen zones 2, 3, 12, 13). There is a small fraction of the granules located in the soft tissues that were not incorporated into the bone.
Discussion
Previous studies done by the authors revealed that BCP ceramic granules with HAp/β-TCP show better bioactivity when compared to pure β-TCP or HAp. Implantation of BCP granules in osteoporotic rabbit bone increased expression of bone activity and repair markers: Osteocalcin, osteopontin, and osteoprotegerin, indicating activation of osteoblastogenesis and bone mineralization in vivo [7].Calcium phosphate was synthesized by aqueous precipitation technique from calcium hydroxide and phosphoric acid, where calcium hydroxide and phosphoric acid were used as raw materials following the reaction of Ca(OH)2 + H3PO4→Ca10−x (HPO4)x (PO4)6−x (OH)2−x + H2O. The filtered precipitates were formed into granules, dried, and sintered at 1150°C for 2 h. The sintered granules were sieved using vibrational sieves to gain the granular fraction in sizes from 1 to 1.4 mm. The BCP ceramic granules were prepared with nanopore sizes around 200 nm, packed into 10 g packs and sterilized. First results of BCP ceramic granules with HAp/β-TCP ratio of 90/10 as bone substitute for reconstruction of the bone defects in orthopedic surgery, such as fracture and fracture non-union treatment, primary and revision arthroplasty, and chronic osteomyelitis, were evaluated [8].Successful bone regeneration using both granules and blocks of BCP materials has been reported in recent literature. Šponer et al. reported that the use of autologous mesenchymal stromal cells combined with a β-tricalcium phosphate scaffold produced bone regeneration comparable with cancellous impaction allografting when treating femur bone defects with jeopardized and/or impaired microenvironment [9]. Ultraporous β-TCP alone or combined with bone marrow aspirate for benign cavitary lesions was used [10].In our report, we found that β-TCP in the implanted BCP granules were absorbed, but HAp, which is 90% of the BCP granules, did not absorb, thus providing long-term bone defect filling. Using HAp/β-TCP for filling bone defects, BCP ceramic granules transplant was adjusted to the bone defect anatomy. Also, the increased porosity of material promoted better bone tissue response. The infection was healed before revision arthroplasty.The standard radiographs in our study were evaluated by two radiologists, experienced in musculoskeletal radiology.To measure the bone deficiency and to classify the femoral bone defect we used Paprosky classification. The Paprosky classification is based on the morphology and the location of the remaining proximal femoral bone and the amount of diaphyseal bone available for distal fixation of the implant. It also provides a structured approach for the choice of surgical treatment in patients undergoing femoral revision arthroplasty [11, 12].The post-operative images after revision total hip arthroplasty posterior and lateral radiographs were reviewed and the bone defect healing was classified using the Gie guidelines in Gruen zones 1–14. The size of defects was measured. We assessed the efficiency of initial granule packing using the classification as follows: excellent, good, fair, poor, defective, not classified. This type of classification is qualitative and cannot be quantified. The granule integration into the bone was classified as: no change, localized resorption, cortical repair, trabecular remodeling, trabecular incorporation, cortical repair and trabecular remodeling, cortical repair and trabecular incorporation, not classified. This classification is empirical, since there is no proof, for example, that the radiological appearance of trabecular incorporation is histologically proven trabecular incorporation and that this process has occurred. However, trabecular remodeling as well as cortical repair could be clearly differentiated on radiographs [13].Merle d’Aubigné-Postel Score was used as it was originally used to evaluate functional results in hip arthroplasties – pain, range of motion, and walking ability [14, 15].
Conclusion
The BCP ceramic granules with HAp/β-TCP material adjusted to the bone defect anatomy showed effective femoral bone defect and periprosthetic fracture healing in a patient with hip arthroplasty revision and periprosthetic fracture.The important characteristic of using BCP ceramic granules with HAp/β-TCP for filling bone defects is that this transplant can be used for effective femoral bone defect and periprosthetic fracture healing in patients with hip arthroplasty revision and periprosthetic fracture where are no metal augmentations for filling these defects. BCP ceramic granules transplant can be adjusted to meet the demands of the bone defect anatomy.
Authors: Kevin J Bozic; Steven M Kurtz; Edmund Lau; Kevin Ong; Thomas P Vail; Daniel J Berry Journal: J Bone Joint Surg Am Date: 2009-01 Impact factor: 5.284
Authors: V Campana; G Milano; E Pagano; M Barba; C Cicione; G Salonna; W Lattanzi; G Logroscino Journal: J Mater Sci Mater Med Date: 2014-05-28 Impact factor: 3.896
Authors: Pavel Šponer; Stanislav Filip; Tomáš Kučera; Jindra Brtková; Karel Urban; Vladimír Palička; Zuzana Kočí; Michael Syka; Aleš Bezrouk; Eva Syková Journal: Biomed Res Int Date: 2016-04-07 Impact factor: 3.411
Authors: Pavel Šponer; Tomáš Kučera; Jindra Brtková; Karel Urban; Zuzana Kočí; Pavel Měřička; Aleš Bezrouk; Šimona Konrádová; Alžběta Filipová; Stanislav Filip Journal: Cell Transplant Date: 2018-09-11 Impact factor: 4.064
Authors: Carlos Henrique Bertoni Reis; Rogerio Leone Buchaim; Karina Torres Pomini; Abdul Latif Hamzé; Isabella Vasconcelos Zattiti; Marco Antonio Hungaro Duarte; Murilo Priori Alcalde; Benedito Barraviera; Rui Seabra Ferreira Júnior; Fenelon Martinho Lima Pontes; Carlos Roberto Grandini; Adriana de Cássia Ortiz; Simone Ortiz Moura Fideles; Renata Maria de Camargo Eugênio; Geraldo Marco Rosa Junior; Daniel de Bortoli Teixeira; Eliana de Souza Bastos Mazuqueli Pereira; João Paulo Galletti Pilon; Maria Angelica Miglino; Daniela Vieira Buchaim Journal: Polymers (Basel) Date: 2022-05-19 Impact factor: 4.967