Literature DB >> 35435202

[Efficacy of vertical control by using mini-implant anchorage in maxillary posterior buccal area for Angle class Ⅱ extraction patients].

W Liang1, Y Tang1, W B Huang1, B Han1, J X Lin1.   

Abstract

OBJECTIVE: To investigate the efficacy of vertical control by using conventional mini-implant anchorage in maxillary posterior buccal area for Angle class Ⅱ extraction patients.
METHODS: Twenty-eight Angle class Ⅱ patients [9 males, 19 females, and age (22.6±2.8) years] were selected in this study. All of these patients were treated by using straight wire appliance with 4 premolars extraction and 2 mini-implant anchorage in maxillary posterior buccal area. In this study, the self-control method was used to measure and analyze the lateral radiographs taken before and after orthodontic treatment in each case, the main cephalometric analysis items were related to vertical changes. The digitized lateral radiographs were imported into Dolphin Imaging Software (version 11.5: Dolphin Imaging and Management Solutions, Chatsworth, California, USA), and marked points were traced. Each marked point was confirmed by two orthodontists. The same orthodontist performed measurement on the lateral radiographs over a period of time. All measurement items were required to be measured 3 times, and the average value was taken as the final measurement result.
RESULTS: Analysis of the cephalometric radiographs showed that, for vertical measurements after treatment, the differences of the following measurements were highly statistically significant (P < 0.001): SN-MP decreased by (1.40±1.45) degrees on average, FMA decreased by (1.58±1.32) degrees on average, the back-to-front height ratio (S-Go/N-Me) decreased by 1.42%±1.43% on average, Y-axis angle decreased by (1.03±0.99) degrees on average, face angle increases by (1.37±1.05) degree on average; The following measurements were statistically significant (P < 0.05): the average depression of the upper molars was (0.68±1.40) mm, and the average depression of the upper anterior teeth was (1.07±1.55) mm. The outcomes indicated that there was a certain degree of upper molar depression after the treatment, which produced a certain degree of counterclockwise rotation of the mandibular plane, resulting in a positive effect on the improvement of the profile.
CONCLUSION: The conventional micro-implant anchorage in maxillary posterior buccal area has a certain vertical control ability, and can give rise to a certain counterclockwise rotation of the mandible, which would improve the profile of Angle Class Ⅱ patients.

Entities:  

Keywords:  Cephalometry; Microscrew implant anchorage; Vertical control

Mesh:

Year:  2022        PMID: 35435202      PMCID: PMC9069030     

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  17 in total

1.  Differences between sliding mechanics with implant anchorage and straight-pull headgear and intermaxillary elastics in adults with bimaxillary protrusion.

Authors:  Isao Koyama; Shoichiro Iino; Yuka Abe; Teruko Takano-Yamamoto; Shouichi Miyawaki
Journal:  Eur J Orthod       Date:  2010-11-08       Impact factor: 3.075

2.  Comparison of treatment outcomes between skeletal anchorage and extraoral anchorage in adults with maxillary dentoalveolar protrusion.

Authors:  Chung-Chen Jane Yao; Eddie Hsiang-Hua Lai; Jenny Zwei-Chieng Chang; I Chen; Yi-Jane Chen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-11       Impact factor: 2.650

3.  Effects of acid etching and calcium chloride immersion on removal torque and bone-cutting ability of orthodontic mini-implants.

Authors:  Tae-Ho Jang; Jae-Hyun Park; Won Moon; Jong-Moon Chae; Na-Young Chang; Kyung-Hwa Kang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2018-07       Impact factor: 2.650

4.  Neuropathological evaluation of an 84-year-old man after 422 ECT treatments.

Authors:  Danielle Anderson; Robert Wollmann; Stephen H Dinwiddie
Journal:  J ECT       Date:  2014-09       Impact factor: 3.635

5.  Vertical control of a Class II deep bite malocclusion with the use of orthodontic mini-implants.

Authors:  Min-Ho Jung
Journal:  Am J Orthod Dentofacial Orthop       Date:  2019-02       Impact factor: 2.650

6.  Effectiveness of mini implants in three-dimensional control during retraction - a clinical study.

Authors:  Deepak Victor; Ramchandra Prabhakar; M K Karthikeyan; R Saravanan; P Vanathi; N Raj Vikram; P Adarsh Reddy; M Sudeepthi
Journal:  J Clin Diagn Res       Date:  2013-11-22

7.  Nonsurgical correction using miniscrew-assisted vertical control of a severe high angle with mandibular retrusion and gummy smile in an adult.

Authors:  Xue-Dong Wang; Jie-Ni Zhang; Da-Wei Liu; Fei-Fei Lei; Wei-Tao Liu; Yang Song; Yan-Heng Zhou
Journal:  Am J Orthod Dentofacial Orthop       Date:  2017-05       Impact factor: 2.650

8.  Mini-implant selection protocol applied to MARPE.

Authors:  Lincoln Issamu Nojima; Matilde da Cunha Gonçalves Nojima; Amanda Carneiro da Cunha; Natan Oliveira Guss; Eduardo Franzotti Sant'Anna
Journal:  Dental Press J Orthod       Date:  2018 Sep-Oct

9.  Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis.

Authors:  Hisham Mohammed; Khaled Wafaie; Mumen Z Rizk; Mohammed Almuzian; Rami Sosly; David R Bearn
Journal:  Prog Orthod       Date:  2018-09-24       Impact factor: 2.750

10.  Effects of cortical bone thickness and trabecular bone density on primary stability of orthodontic mini-implants.

Authors:  Chin-Yun Pan; Pao-Hsin Liu; Yu-Chuan Tseng; Szu-Ting Chou; Chao-Yi Wu; Hong-Po Chang
Journal:  J Dent Sci       Date:  2019-07-20       Impact factor: 2.080

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.