| Literature DB >> 35434012 |
Tao Lu1, Yishuang Wang1, Aiwen Guo1, Cui Wei1, Yazheng Chen1, Shaoyu Wang2, Bin Song3.
Abstract
Background: Using magnetic resonance imaging (MRI) to explore the changes in microvascular perfusion fraction and the heterogeneity of the placenta during pregnancy.Entities:
Keywords: Diffusion kurtosis imaging (DKI); diffusion magnetic resonance imaging (diffusion MRI); intravoxel incoherent motion; magnetic resonance imaging; placenta
Year: 2022 PMID: 35434012 PMCID: PMC9011236 DOI: 10.21037/atm-22-1037
Source DB: PubMed Journal: Ann Transl Med ISSN: 2305-5839
Figure 1Flowchart of the study design. PAS, placenta accreta spectrum disorders; MR, magnetic resonance; DWI, diffusion-weighted imaging; DKI, diffusion kurtosis imaging; IVIM, intravoxel incoherent motion MR imaging.
Figure 2ROI of one slice of the placenta. ROI, region of interest.
Figure 3Diffusion weighted images of the placenta in a 37-week-old gestation woman. T2WI, T2 weighted imaging; DWI, diffusion-weighted imaging; IVIM, intravoxel incoherent motion MR imaging; DKI, diffusion kurtosis imaging; ADC, apparent diffusion coefficient; eADC, exponential ADC; f, perfusion fraction; D, pure diffusion coefficient; D*, pseudo-diffusion coefficient; MD, diffusion coefficient; MK, diffusion kurtosis.
Inter-reader reproducibility for DWI, DKI, IVIM parameters and volume of the whole placenta
| Parameters | ICC (95% CI) | P value |
|---|---|---|
| Standard DWI parameters | ||
| ADC mean (×10–3 mm2/s) | 0.988 (0.955–0.997) | 0.000 |
| ADC min (×10–3 mm2/s) | 0.842 (0.505–0.958) | 0.001 |
| ADC max (×10–3 mm2/s) | 0.903 (0.664–0.975) | 0.000 |
| eADC mean | 0.991 (0.965–0.998) | 0.000 |
| eADC min | 0.844 (0.504–0.959) | 0.001 |
| eADC max | 0.964 (0.870–0.991) | 0.000 |
| DKI parameters | ||
| MD mean (×10–3 mm2/s) | 0.870 (0.562–0.966) | 0.000 |
| MD min (×10–3 mm2/s) | 0.751 (0.249–0.932) | 0.005 |
| MD max (×10–3 mm2/s) | 0.767 (0.341–0.935) | 0.002 |
| MK mean | 0.991 (0.965–0.998) | 0.000 |
| MK min | N/A | N/A |
| MK max | 0.790 (0.383–0.958) | 0.002 |
| IVIM parameters | ||
| f mean (%) | 0.896 (0.647–0.973) | 0.000 |
| f min (%) | N/A | N/A |
| f max (%) | N/A | N/A |
| D mean (×10–3 mm2/s) | 0.980 (0.924–0.995)) | 0.000 |
| D min (×10–3 mm2/s) | 0.892 (0.639–0.972) | 0.000 |
| D max (×10–3 mm2/s) | 0.950 (0.822–0.987) | 0.000 |
| D* mean (×10–3 mm2/s) | 0.832 (0.454–0.956) | 0.000 |
| D* min (×10–3 mm2/s) | 0.990 (0.962–0.998) | 0.000 |
| D* max (×10–3 mm2/s) | N/A | N/A |
| Volume (mL) | 0.953 (0.831–0.956) | 0.000 |
DWI, diffusion-weighted imaging; DKI, diffusion kurtosis imaging; IVIM, intravoxel incoherent motion MR imaging; ICC, intraclass correlation coefficient; CI, confidence interval; ADC, apparent diffusion coefficient; eADC, exponential ADC; MD, diffusion coefficient; MK, diffusion kurtosis; f, perfusion fraction; D, pure diffusion coefficient; D*, pseudo-diffusion coefficient.
Correlation between quantitative MRI parameters, volume of the whole placenta and the gestational week in the normal placenta
| Parameters | Gestational weeks | |
|---|---|---|
| r (95% CI) | P value | |
| Standard DWI parameters | ||
| ADC mean (×10–3 mm2/s) | –0.508 (–0.787 to 0.074) | 0.016 |
| ADC min (×10–3 mm2/s) | –0.548 (–0.816 to 0.061) | 0.008 |
| ADC max (×10–3 mm2/s) | 0.048 (–0.323 to 0.339) | 0.833 |
| eADC mean | 0.565 (–0.085 to 0.846) | 0.006 |
| eADC min | 0.252 (–0.528 to 0.141) | 0.258 |
| eADC max | 0.460 (0.055 to 0.747) | 0.031 |
| DKI parameters | ||
| MD mean (×10–3 mm2/s) | –0.195 (–0.601 to 0.254) | 0.362 |
| MD min (×10–3 mm2/s) | –0.673 (–0.874 to 0.438) | 0.001 |
| MD max (×10–3 mm2/s) | –0.236 (–0.546 to 0.255) | 0. 291 |
| MK mean | 0.524 (0.069 to 0.807) | 0.012 |
| MK min | N/A | N/A |
| MK max | 0.801 (0.504 to 0.928) | 0.008 |
| IVIM parameters | ||
| f mean (%) | 0.103 (–0.310 to 0.399) | 0.650 |
| f min (%) | –0.328 (–0.602 to 0.260) | 0.136 |
| f max (%) | N/A | N/A |
| D mean (×10–3 mm2/s) | –0.552 (–0.828 to 0.144)) | 0.008 |
| D min (×10–3 mm2/s) | –0.697 (–0.873 to 4.238) | 0.000 |
| D max (×10–3 mm2/s) | –0.167 (–0.509 to 0.20) | 0.457 |
| D* mean (×10–3 mm2/s) | 0.147 (–0.451 to 0.498) | 0.515 |
| D* min (×10–3 mm2/s) | –0.594 (–0.811 to 0.239) | 0.004 |
| D* max (×10–3 mm2/s) | N/A | N/A |
| Volume (mL) | 0.566 (0.149 to 0.834) | 0.006 |
MRI, magnetic resonance imaging; CI, confidence interval; DWI, diffusion-weighted imaging; ADC, apparent diffusion coefficient; eADC, exponential ADC; DKI, diffusion kurtosis imaging; MD, diffusion coefficient; MK, diffusion kurtosis; IVIM, intravoxel incoherent motion MR imaging; f, perfusion fraction; D, pure diffusion coefficient; D*, pseudo-diffusion coefficient.
Correlation between quantitative MRI parameters and volume of the whole placenta
| Parameters | Volume | |
|---|---|---|
| r (95% CI) | P value | |
| Standard DWI parameters | ||
| ADC mean (×10–3 mm2/s) | –0.156 (–0.592 to 0.347) | 0.488 |
| ADC min (×10–3 mm2/s) | –0.231 (–0.619 to 0.304) | 0.301 |
| ADCmax (×10–3 mm2/s) | –0.141 (–0.562 to 0.193) | 0.533 |
| eADC mean | 0.171 (–0.328 to 0.592) | 0.446 |
| eADC min | –0.111 (–0.507 to 0.315) | 0.622 |
| eADC max | 0.254 (0.249 to 0.682) | 0.255 |
| DKI parameters | ||
| MD mean (×10–3 mm2/s) | 0.266 (–0.187 to 0.658) | 0.232 |
| MD min (×10–3 mm2/s) | –0.343 (–0.681 to 0.129) | 0.118 |
| MD max (×10–3 mm2/s) | 0.105 (–0.376 to 0.539) | 0. 642 |
| MK mean | 0.250 (–0.238 to 0.645) | 0.261 |
| MK min | N/A | N/A |
| MK max | 0.518 (0.1 to 0. 8) | 0.014 |
| IVIM parameters | ||
| f mean (%) | 0.509 (0.046 to 0.774) | 0.015 |
| f min (%) | –0.292 (–0.598 to 0.119) | 0.187 |
| f max (%) | N/A | N/A |
| D mean (×10–3 mm2/s) | –0.168 (–0.598 to 0.321)) | 0.456 |
| D min (×10–3 mm2/s) | –0.377 (–0.734 to 0.085) | 0.084 |
| D max (×10–3 mm2/s) | –0.220 (–0.604 to 0.234) | 0.326 |
| D* mean (×10–3 mm2/s) | –0.325 (–0.701 to 0.163) | 0.140 |
| D* min (×10–3 mm2/s) | –0.198 (–0.609 to 0.368) | 0.378 |
| D* max (×10–3 mm2/s) | N/A | N/A |
MRI, magnetic resonance imaging; CI, confidence interval; DWI, diffusion-weighted imaging; ADC, apparent diffusion coefficient; eADC, exponential ADC; DKI, diffusion kurtosis imaging; MD, diffusion coefficient; MK, diffusion kurtosis; IVIM, intravoxel incoherent motion MR imaging; f, perfusion fraction; D, pure diffusion coefficient; D*, pseudo-diffusion coefficient.