Literature DB >> 35426042

Coulometric back titration based on all-solid-state electrodes for phenylephrine hydrochloride determination.

Qiuyu Kong1, Jinghao Wu1, Meng Chen2, Zuanguang Chen3.   

Abstract

Existing coulometric titration generally used liquid reference electrodes, with limitations of frequent maintenance and liquid leakage risk and requiring vertical working position. Herein, we proposed an all-solid coulometric titration based on the glassy carbon electrode (GCE) and preliminarily utilized it in phenylephrine hydrochloride (PHE) analysis with a universal back titration program. Subsequently, the long-term stability of the GCE in bromine and iodine solution was evaluated comprehensively by electrochemical characterization and titration measurement. The results presented an excellent linear relationship between electrolysis time and PHE concentration from 0.3 to 20 mM, with a limit of detection of 0.07 mM (3 S0/S). It also showed an excellent standard recovery rate and a short testing time within 10 min. Compared with bromometry in the pharmacopoeia, the all-solid coulometric titration exhibited higher accuracy and precision in formulation detection with simpler operation. The long-term stability experiments indicated that the potential difference mutation was unaffected by the electrochemical property of the GCE. Conclusively, this enabling work provided an all-solid coulometric titration for drug determination without maintenance in the long term and contributed to its further integration and industrialization.
© 2022. Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Corrosion resistance; Coulometric titration; Drug determination; Electrochemistry; Solid-state electrodes

Mesh:

Substances:

Year:  2022        PMID: 35426042     DOI: 10.1007/s00216-022-04063-x

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  7 in total

1.  Determination of total fluoride in HF/HNO3/H2SiF6 etch solutions by new potentiometric titration methods.

Authors:  Wenke Weinreich; Jörg Acker; Iris Gräber
Journal:  Talanta       Date:  2006-10-20       Impact factor: 6.057

2.  Coulometric titration with electrogenerated oxidants as a tool for evaluation of cognac and brandy antioxidant properties.

Authors:  Guzel Ziyatdinova; Inna Salikhova; Herman Budnikov
Journal:  Food Chem       Date:  2013-11-04       Impact factor: 7.514

3.  Paper-based electroanalytical devices with an integrated, stable reference electrode.

Authors:  Wen-Jie Lan; E Jane Maxwell; Claudio Parolo; David K Bwambok; Anand Bala Subramaniam; George M Whitesides
Journal:  Lab Chip       Date:  2013-08-23       Impact factor: 6.799

4.  A new method for determining the acid number of biodiesel based on coulometric titration.

Authors:  Fabiano Barbieri Gonzaga; Sidney Pereira Sobral
Journal:  Talanta       Date:  2012-04-12       Impact factor: 6.057

5.  Automated constant-current coulometric assay system for ascorbic acid and sodium ascorbate.

Authors:  S A Moros; C M Hamilton; J E Heveran; J J Donahue; S Oliveri-Vigh
Journal:  J Pharm Sci       Date:  1975-07       Impact factor: 3.534

6.  All-solid-state reference electrodes based on conducting polymers.

Authors:  Anna Kisiel; Honorata Marcisz; Agata Michalska; Krzysztof Maksymiuk
Journal:  Analyst       Date:  2005-10-27       Impact factor: 4.616

7.  Adsorption studies of the herbicide simazine in agricultural soils of the Aconcagua valley, central Chile.

Authors:  Cecilia Flores; Verónica Morgante; Myriam González; Rodrigo Navia; Michael Seeger
Journal:  Chemosphere       Date:  2008-12-19       Impact factor: 7.086

  7 in total
  1 in total

1.  Coulometer from a Digitally Controlled Galvanostat with Photometric Endpoint Detection.

Authors:  Domingo González-Arjona; Emilio Roldán González; Germán López-Pérez; Manuel María Domínguez Pérez; Marina Calero-Castillo
Journal:  Sensors (Basel)       Date:  2022-10-05       Impact factor: 3.847

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.