Long-term performance of untreated fresh autologous pericardium as a valve substitute in pulmonary position.

Shantanu Pande1, Amitabh Arya2, Surendra K Agarwal1, Prabhat Tewari3, Aditya Kapoor4, Neetu Soni5, Sunil Kumar5.   

Abstract

Background: Pulmonary regurgitation is imminent after transannular patch (TAP). We analyze the long-term performance of untreated autologous pericardium (UAP) as valve substitute at pulmonary position in patients requiring TAP. Material and
Methods: This cross-sectional study include patients operated between 2007 and 2012 (n = 92). A sample of 19 patients was selected for this study which had a follow-up of more than 3 years. This includes patients with no TAP (n = 4) and with TAP and valve substitute, a monocusp (n = 11) or a tricuspid valve (n = 4) at neopulmonary annulus. Patients underwent echocardiography for assessment of right ventricle function and 18 fluoro-deoxyglucose PET CT scan for measurements of valve substitute at neopulmonary annulus. The target to blood ratio (TBR) of uptake of glucose by monocusp was measured at the cooptation edge of the neopulmonary valve.
Results: The median age of the patients is 14 (9 - 37). RV function is preserved (TAPSE 18.9 (10.6 - 22.8)) at a mean follow-up of 4 years (3-9). The measurements of monocusp shows a shrinkage in height of the cusp by 35.5% (70% - 1.0%) and length by 7% (-44% - +104%). There was less shrinkage observed in patients below 15 years of age. The TBR of monocusp was 0.945 (0.17 - 3.35) with a strong correlation between the TBR values of aortic valve leaflet and monocusp leaflet of same patient.
Conclusion: The UAP is functional and successful as a valve substitute at neo pulmonary annulus at long-term follow-up. It has resisted calcification and has shown uptake of glucose in physiological limits.

Entities:  

Keywords:  Heart valve; pulmonary stenosis; pulmonary valve

Mesh:

Substances:

Year:  2022        PMID: 35417962      PMCID: PMC9244266          DOI: 10.4103/aca.aca_22_21

Source DB:  PubMed          Journal:  Ann Card Anaesth        ISSN: 0971-9784


BACKGROUND

Pulmonary regurgitation (PR) is an integral downside of intracardiac repair in tetralogy of Fallot (TOF) requiring a transannular patch.[1] Free PR that arises due to transannular patch for reconstruction of right ventricular outflow tract has detrimental perioperative and long-term results. During early postoperative period, severe PR causes low cardiac output.[2] While, if PR persists for long-term it can cause right ventricle dysfunction and subsequently pulmonary valve replacement.[3] Various techniques and material were used by surgeons over years to control appearance of free PR during index operation.[4] Traditionally, untreated autologous pericardium was utilized with not very encouraging early and midterm results.[5] They were considered to disappear by resorption and retraction and soon were replaced by glutaraldehyde treated autologous pericardium at pulmonary position as monocusp valve for right ventricular outflow tract (RVOT) reconstruction with good midterm results.[6] Some groups started using poly tetra fluoro ethylene (PTFE) membrane for reconstruction of pulmonary valve and have shown acceptable midterm results.[7] Apart from techniques of creating a monocusp, bicuspid or a tricuspid valve at pulmonary position some groups perform aggressive debulking and release of native pulmonary valve and annulus with acceptance of a small z value to contain the PR after RVOT reconstruction.[8] In addition to this knowledge, we have been using untreated fresh autologous pericardium for reconstruction of pulmonary valve in subset of TOF requiring trans annular patch for a decade now. We analyze the hemodynamic and physiologic performance of untreated pericardium used as a valve in long-term.

MATERIAL AND METHODS

This is a cross sectional study performed at a single center. Between January 2007 and December 2012, 92 patients of tetralogy of Fallot were operated in the unit. Of these 72 patients required trans annular patch for complete intracardiac repair of the TOF. All the patients requiring a TAP, received some kind of procedure for creation of a competent pulmonary valve (valve substitute). The procedure to achieve a competent valve was performed at newly created pulmonary annulus after the use of trans annular patch. It was either a monocusp (n = 61) created on the TAP anteriorly or a tricuspid pulmonary valve (n = 11) after complete excision of the native pulmonary valve.[910] The material used for creating a competent pulmonary valve in both these techniques was untreated fresh autologous pericardium. This study was approved by the research and ethics committee of the institute. Funds were granted to include up to 20% of cases for this study. The inclusion criteria were, patient with more than 3 years of follow-up, in normal sinus rhythm and absence of allergy to iodine-based dye. Patients who came for follow-up were offered the chance to participate in the study and it was closed when desired numbers were reached. Those patients were excluded who did not consent and presented with rhythm abnormalities. Finally, 19 patients participated in the study. Fifteen patients required a transannular patch during operation and of these 11 received a monocusp valve and 4 received a tricuspid valve at pulmonary position. Four patients did not require a TAP and thus their pulmonary valve was not violated. The patients were grouped into 2 categories. Group 1 (n = 4), included patients with normal pulmonary valve and no TAP while group 2 (n = 15) has patients with TAP and either a monocusp or a tricuspid valve. The clinical data was collected through an interview and operative details were accessed through hospital information system. The patients were evaluated for right ventricular function, degree of PR and gradient across the right ventricular outflow tract using Philips HD echocardiography machine and a 3.2-MHz transducer (Philips Medical Systems, Andover, MA).

Assessment of right ventricular function

It was done using Myocardial Performance Index (MPI), Tricuspid Annular Plane Systolic Excursion (TAPSE). A value of MPI of 0.40 and TAPSE of <14 mm was considered as severe right ventricular dysfunction.[1112]

Assessment of Pulmonary regurgitation and gradient across RVOT

PR was assessed by pulmonary end diastolic velocity and labelled as severe when it reached zero. If not severe, the PR was labelled as hemodynamically significant if its duration was less than 70% of diastolic duration.[13] Assessment of gradient across RVOT was done on continuous wave doppler by assessment of velocity across it.

Assessment for dimensions of the FAP used in creation of competent pulmonary valve

A contrast cardiac PET CT scan study was performed in all the patients to study the anatomy of the untreated autologous pericardium (UAP) at the follow-up. All the patients were kept fasting overnight and were injected 18-Fluoro Deoxy Glucose 45 minutes before commencement of the study. A 64 slice CT scanner was used for the purpose (Biograph by Siemens, Munich, Germany). A prospective electrocardiogram gated scan was performed with 0.9 mm thickness with controlled heart rate of <70 beats/minute. The trigger was kept in right ventricle and area of interest for study was right ventricle, RVOT and pulmonary valve with main pulmonary artery. The anatomy was evaluated on CT images. A non-ionic contrast (Visipaque) was used for this study. Since majority of patients (n = 11) has a monocusp of UAP, the anterior leaflet (cusp) of pulmonary valve was evaluated in all the patients to have uniformity in comparison. The assessment was done for height (coaptation surface), width (circumference of the cusp along the annulus) and thickness of the anterior cusp of neo pulmonary valve.

Assessment of uptake of 18 Fluoro Deoxy Glucose (18-FDG) by valves

Following completion of the CT scan protocol, the patients were scanned for positron emission tomography (PET) in the same position for next 45 minutes. The overlapping of the two images was done to create the data for assessment of 18-FDG uptake by the native aortic valve, native pulmonary valve (in 11 cases of monocusp of UAP where the native pulmonary valves were retained during total correction, these are located posteriorly on the pulmonary annulus). The standard uptake value (SUV) of 8 mm circle was calculated at the valve leaflet near their coapting edges. This was done to remove any overlap that may have occurred due to uptake by the wall of great arteries. The calculation for UAP was done in the anterior leaflet of the neo pulmonary valve. The target blood ratio (TBR, was calculated as a ratio of SUV of the target tissue and the SUV of the blood pool) from attenuation corrected images was achieved and is used in statistical analysis as uptake of glucose by the valve leaflet tissue.

Statistics

The data is presented in median (minimum – maximum). The comparison between different style of neo pulmonary valve is done using non-parametric test, Mann Whitney U test. Pearson correlation is calculated between different variables. SPSS version 17 for windows is used for statistical analysis.

RESULTS

The median age of the patients is 14 years (9 – 37) and there are 16 males and 3 females in this study. The complete data of 19 patients for echocardiography is presented in Table 1, for measurements of monocusp, based on CT scan, in Table 2 and glucose uptake in Table 3. While comparing group 1 and 2, there was no difference in the age of the patients (13 years (9 – 17) vs 16 years (10 – 37), P = 0.73) or their distribution based on sex (3 males and 1 female vs 13 males and 2 females, P = 0.26). The right ventricular function was similar in two groups, TAPSE in mm of 16.9 (13.9 – 19.4) in group 1 vs 19 (10.6 – 22.8) in group 2 P = 0.53 and MPI of 0.28 (0.05 – 0.56) in group 1 vs 0.09 (0.01 – 0.41) in group 2 P = 0.50. The comparison of the function of preserved native pulmonary in group 1 and the reconstructed pulmonary valve in group 2 is presented in Table 4. The uptake of glucose by monocusp, native pulmonary valve leaflet and aortic valve leaflet is displayed in Figure 1. The measurements and appearance of monocusp in CT scan obtained image is presented in Figure 2. There was no evidence of calcium deposition in any scan. Figure 3, displays the PET CT attenuation corrected image of the same patient. The TBR of glucose uptake was 0.945 (0.17 – 3.35) for monocusp, 0.805 (0.14 -0.328) for native pulmonary leaflet and 1.05 (0.21 – 3.71) for aortic valve leaflet. There is a strong correlation between TBR of monocusp and the period of follow-up (r = 0.601, P = 0.01). There is also a strong positive correlation between the TBR of monocusp and aortic valve leaflet (r = 0.956, P = 0.001) and monocusp and native pulmonary valve leaflet (0.958, P = 0.001). There was change in the size of pericardium at the follow-up. In all 15 patients in which UAP was used to create a pulmonary valve there was change in the size of the pericardium used to create anterior cusp. The change is shrinkage in height by 35.5% (70 – 1.0) and width by 7% (-44% - +104%) from its initial dimensions. When the size of the pericardium measured at follow-up is compared to its size at the time of implantation, there is a significant shrinkage in height (25 mm (12 – 30) at the time of implantation vs 13.5 mm (8.9 – 19.4) at the time of follow-up, P = 0.007). While the length of the pericardium slightly decreased though not significantly (25 mm (4.71 – 30) vs 23.4 (4.9 – 40.9), P = 0.91). The change in size of the pericardium used for monocusp was relatively less in patients younger than 15 years Figure 4.
Table 1

Echocardiography derived right ventricle function parameters

PatientType of PVMPITAPSE in mmMean PV gradient in mmHgPR in gradePR end diastolic velocity in cm/secEOA in cm2/m2
1Native normal PV0.4819.407.00138.801.37
20.5613.9010.00138.801.60
30.0515.008.00496.401.83
40.0818.909.00145.501.85
5Monocusp of UAP Pericardium at PV annulus0.1922.7011.00442.402.45
60.0714.7010.00168.801.25
70.0818.705.002160.001.70
80.0716.0013.00210.901.22
90.1620.9030.00269.202.45
100.0719.0017.00138.001.25
110.0816.0016.00351.603.09
120.1022.7022.00295.002.09
130.2420.0023.00177.401.95
140.3111.708.00465.006.53
150.1022.8012.00489.601.44
16Tricuspid neo PV created from UAP0.0110.6010.00450.201.79
170.1919.0027.00265.401.54
180.4121.9019.004102.001.07
190.0613.0013.00242.100.835

MPI: Myocardial Performance Index, PV: Pulmonary Valve, PR: Pulmonary Regurgitation, UAP: Untreated autologous pericardium

Table 2

Anatomical measurements of UAP of anterior leaflet of reconstructed pulmonary valve on CT scan

PatientType of PVAgeWidth of UAP created anterior cusp of PV at operation in mmHeight of UAP created anterior cusp of PV at operation in mmWidth of UAP Anterior cusp at follow-up in mmHeight of UAP Anterior cusp in follow-up in mmThickness of UAP Anterior cusp at follow-up in mm
1Native normal PV1212.0010.401.40
21714.1011.101.60
31415.5010.901.25
40914.4010.301.50
5Monocusp of UAP at PV annulus1715.7125.0025.6012.901.70
61020.0022.0019.6017.401.30
72330.0030.0027.9019.001.70
81230.0030.0015.2018.001.70
92425.0030.0029.208.902.50
102125.0025.0028.4015.403.00
111620.0020.0039.5013.202.00
121430.0030.0024.0022.001.50
131425.0025.0018.0016.001.10
141825.0021.0022.5020.002.60
15124.7112.004.909.701.60
16Tricuspid neo PV created from UAP1020.0021.0029.0013.501.60
171020.0015.0040.9015.702.10
183725.0030.0013.9019.401.60
193130.0030.0022.8020.002.60

PV: Pulmonary valve, UAP: Untreated autologous pericardium

Table 3

Measurements of uptake of glucose as TBR in PET scan

Patient Type of PVFollow-up period in yearsTBR of UAP Anterior cusp of PVTBR of native aortic valveTBR of native pulmonary valve
1Native normal PV30.240.200.30
250.260.210.42
330.180.210.14
440.200.240.18
5Monocusp of UAP at PV annulus40.170.430.24
640.900.750.66
731.251.451.25
830.540.660.73
971.041.271.22
1070.941.331.33
1140.951.270.76
1291.241.431.13
1381.471.00o. 91
1440.820.880.82
1530.820.600.66
16Tricuspid neo PV created from UAP61.041.10
1793.353.71
1830.370.39
1931.221.83

PET: Positron emission tomography, PV: Pulmonary valve, TBR: Target blood ration of standard uptake value, UAP: Untreated autologous pericardium

Table 4

Function of neo pulmonary valve in follow-up Echocardiography

VariableGroup I n=4Group II n=15P
Peak Gradient in mmHg15.5 (14 - 20)35 (10 - 62)0.02
Mean gradient in mm Hg8.5 (7 - 10)14.5 (5 - 30)0.02
RVSP in mm Hg41 (39 - 43)41 (36 - 53)1.0
TR grade1 (0 - 2)1 (1 - 4)0.66
PAEDV42.4 (38.8 - 96.4)68.8 (10.9 - 160)0.70
EOAI cm/m21.46 (1.13 - 4.86)2.11 (0.99 - 4.17)0.50

RVSP: Right Ventricular Systolic Pressure, TR: Tricuspid Regurgitation, PAEDV: Pulmonary artery End Diastolic Velocity, EOAI: Effective Orifice Area Index

Figure 1

Displays correlation between TBR (Target blood ratio of standard uptake value of 18 fluoro deoxy glucose) between monocusp of untreated autologous pericardium, aortic valve leaflet and native pulmonary valve

Figure 2

CT scan images in different views showing monocusp leaflet of neo pulmonary valve (thin arrow) and native pulmonary valve leaflet (thick arrow)

Figure 3

Fused positron emission tomography and CT images of the same patient as in Figure 2

Figure 4

Difference in shrinkage of monocusp from its initial dimensions in patients with age less or more than 15 years

Echocardiography derived right ventricle function parameters MPI: Myocardial Performance Index, PV: Pulmonary Valve, PR: Pulmonary Regurgitation, UAP: Untreated autologous pericardium Anatomical measurements of UAP of anterior leaflet of reconstructed pulmonary valve on CT scan PV: Pulmonary valve, UAP: Untreated autologous pericardium Measurements of uptake of glucose as TBR in PET scan PET: Positron emission tomography, PV: Pulmonary valve, TBR: Target blood ration of standard uptake value, UAP: Untreated autologous pericardium Function of neo pulmonary valve in follow-up Echocardiography RVSP: Right Ventricular Systolic Pressure, TR: Tricuspid Regurgitation, PAEDV: Pulmonary artery End Diastolic Velocity, EOAI: Effective Orifice Area Index Displays correlation between TBR (Target blood ratio of standard uptake value of 18 fluoro deoxy glucose) between monocusp of untreated autologous pericardium, aortic valve leaflet and native pulmonary valve CT scan images in different views showing monocusp leaflet of neo pulmonary valve (thin arrow) and native pulmonary valve leaflet (thick arrow) Fused positron emission tomography and CT images of the same patient as in Figure 2 Difference in shrinkage of monocusp from its initial dimensions in patients with age less or more than 15 years

DISCUSSION

The need for inclusion of a competent pulmonary valve following repair of tetralogy of fallot is to prevent right ventricular failure arising out of the effect of long-standing pulmonary regurgitation.[14] However, a dream of competent pulmonary valve after a transannular patch, though utopian, has been regarded as a fool's errand.[15] In our study of fairly long follow-up, the function of right ventricle was preserved in all the patients as reported by other studies.[16] This has also been documented in 5-year follow-up of repaired tetralogy of fallot in our experience.[17] A long-term exposure of pulmonary regurgitation is physiologically untenable for right ventricle to maintain its function and eventually it fails.[18] Hence authors believe any attempt to mitigate the development of pulmonary regurgitation will help in delaying the development of right ventricle dysfunction. Pulmonary regurgitation was moderate in most of our patients and effective orifice area indexed was also in normal range, hence the construction of neo valve at pulmonary annulus had prevented ballooning of the transannular patch and free pulmonary regurgitation. The method for inserting a monocusp in right ventricular outflow as patch rather than at annulus has failed to be functional at follow-up.[19] It is also documented in our study, that this neo pulmonary valve is non-obstructive at long term follow-up as evidenced by an acceptable mean gradient across it of <30 mm Hg. In our study, we used autologous untreated pericardium for preparation of a competent pulmonary valve either as monocusp or a tricuspid valve. It is observed in follow-up with CT scan, that the autologous pericardium has no deposition of calcium in all our patients. However, it has revealed thickness and distortion. This change can be explained by excessive fibroblastic activity. Grabenwoger et al. experimented with autologous and heterologous pericardial valve, on explanation they found the autologous tissue to be free of calcification but heterologous valve failed because of calcification of the tissue. They had treated the autologous pericardium with glutaraldehyde hence the growth of collagen was missing in their study.[20] Dham et al. demonstrated their experience with autologous pericardial valve (ATCV).[21] They did histopathological study in two failure patients. The method of failure was shrinkage and thickening in one case and collagen degeneration in other. They short tanned the pericardium with glutaraldehyde.[22] We have observed shrinkage in height of the cusp in our patients. This has been the reported problem with the use of untreated pericardium.[23] Though in our series we have noted growth in width of the monocusp, more significantly in patients who were below 15 years. This observation in our study may because of the inherent property of the untreated pericardium to increase in length on stretch with the capability of regain its normal size after few hours.[24] In our experience the pericardium used as monocusp, increased in length (the aspect of monocusp that was stitched along the neo pulmonary annulus) while it shrinks in height (the coapting height of monocusp). Haluk et al. has also reported increase in the size of untreated pericardium when they used it as a patch on aorta in experimental animal.[25] Similarly, Quinn et al. has reported successful use of untreated pericardium for mitral valve repair. They report that after 10 years of follow-up, the pericardium thus used, shows no calcification, aneurysmal dilation or stiffness.[26] We also observed similar characteristics in monocusp made from untreated autologous pericardium. PET scan in our study reveals uptake of glucose by the monocusp. This uptake of glucose is similar to the uptake of glucose by the aortic valve and native pulmonary valve leaflet of the same patient. Marincheva-Savcheva et al. reported increased uptake of glucose by the stenosed aortic valve. They have discussed the uptake in aortic stenosis as a part of inflammation. The mean valve for uptake in mild aortic stenosis was 1.35 which is higher than that observed in our study.[27] It is also noteworthy that in patients who did not require a monocusp and thus had normal pulmonary valve had lower uptake value of glucose. However, in monocusp category the uptake of glucose was increased in aortic as well as monocusp, though in approximately equal proportions. It was observed after a valve implantation that there was targeting of the area by host reaction.[28] This is later followed by increased collagenization and re endothelization.[28] Mathieu et al. has reported uptake around the sewing ring of the bio prosthetic valve even at 1 year and has hypothesized that this remodeling process (increased fibrous reaction) may be the reason for increased uptake.[29] The uptake in cases of infection and inflammation is much higher in numbers than observed in our study. Kieder et al. has reported increased uptake of glucose in case of implantation of vascular prosthesis while in cases of native vein graft these values were significantly reduced.[30] In our cases the uptake of glucose may be similarly explained by the remodeling process of the autologous pericardium. The free edge of the monocusp possibly got retracted due to collagenization. The monocusp in our study has thus shown all the characteristics of a living tissue, however there was retraction in its free edge which is a concern. The use of untreated pericardium as a material to create a valve will in future be decided by the fact if its remodeling process can be altered favorably. This study has few limitations and future efforts must be directed to addressing them. All the patients treated could not be enrolled in this study for follow-up. This created a bias in selection of patients. We have compared two techniques for creating a competent pulmonary valve, the monocusp and a tricuspid valve. Both of these would create different amount of stress on the FAP valve cusp, thus altering the amount of injury and hence healing response.

CONCLUSION

This study establishes the presence of a supple, non-calcified, monocusp leaflet which is able to reduce the pulmonary regurgitation and maintain normal functioning of right ventricle at long term. Though this monocusp has demonstrated thickening with retraction in its free (coopting) edge, it has also demonstrated its capability to increases in length so that the neo pulmonary annulus can grow to meet the demand of growing child. The standardization of design of the neo pulmonary valve and modulation of the remodeling of autologous pericardium will be required for the success of such valves.
  30 in total

1.  TEFLON AND PERICARDIAL AORTIC VALVE PROSTHESES.

Authors:  V O BJOERK; G HULTQUIST
Journal:  J Thorac Cardiovasc Surg       Date:  1964-06       Impact factor: 5.209

Review 2.  Problems with the right ventricular outflow tract: a review of morphologic features and current therapeutic options.

Authors:  Luca A Vricella; Mazyar Kanani; Andrew C Cook; Duke E Cameron; Victor T Tsang
Journal:  Cardiol Young       Date:  2004-10       Impact factor: 1.093

3.  Pathophysiology of early failure of autologous aortic heart valves (ATCV).

Authors:  M Dahm; D Prüfer; G Dohmen; E Mayer; E Groh; Y H Choi; H Oelert
Journal:  Thorac Cardiovasc Surg       Date:  1998-12       Impact factor: 1.827

4.  Right ventricular outflow tract strategies for repair of tetralogy of Fallot: effect of monocusp valve reconstruction.

Authors:  Lior Sasson; Sion Houri; Alona Raucher Sternfeld; Ilan Cohen; Orit Lenczner; Edward L Bove; Livia Kapusta; Akiva Tamir
Journal:  Eur J Cardiothorac Surg       Date:  2012-09-28       Impact factor: 4.191

5.  Different modes of degeneration in autologous and heterologous heart valve prostheses.

Authors:  M Grabenwöger; F Fitzal; C Gross; D Hutschala; P Böck; P Brucke; E Wolner
Journal:  J Heart Valve Dis       Date:  2000-01

6.  Assessment of a right-ventricular infundibulum-sparing approach in transatrial-transpulmonary repair of tetralogy of Fallot.

Authors:  Thierry Bové; Katrien François; Kristof Van De Kerckhove; Joseph Panzer; Katya De Groote; Daniel De Wolf; Guido Van Nooten
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

7.  Reconstruction of trileaflet pulmonary valve using autologous pericardium.

Authors:  Shantanu Pande; Surendra K Agarwal; Gauranga Majumdar; Mahendra Narwaley; Ram K Shukla; Mayank Arora
Journal:  Heart Lung Circ       Date:  2011-03-24       Impact factor: 2.975

8.  Short-term clinical and echocardiographic outcomes after use of polytetrafluoroethylene bicuspid pulmonary valve during the repair of tetralogy of Fallot.

Authors:  Prashant Ramdas Wankhade; Neeraj Aggarwal; Reena Khantwal Joshi; Mridul Agarwal; Raja Joshi; Ashwani Mehta; Sibashankar Kar
Journal:  Ann Pediatr Cardiol       Date:  2019 Jan-Apr

9.  The autologous tissue cardiac valve: a new paradigm for heart valve replacement.

Authors:  J N Fabiani; G D Dreyfus; M Marchand; J Jourdan; M Aupard; C Latrémouille; C Chardigny; A F Carpentier
Journal:  Ann Thorac Surg       Date:  1995-08       Impact factor: 4.330

10.  Fate of the pericardial monocusp pulmonary valve for right ventricular outflow tract reconstruction. Early function, late failure without obstruction.

Authors:  S R Gundry; A J Razzouk; J F Boskind; R Bansal; L L Bailey
Journal:  J Thorac Cardiovasc Surg       Date:  1994-03       Impact factor: 5.209

View more
  1 in total

1.  Trileaflet semilunar valve reconstruction: pulsatile in vitro evaluation.

Authors:  Lisa Carlson Hanse; Marcell J Tjørnild; Simon G Sørensen; Peter Johansen; Ignacio Lugones; Vibeke E Hjortdal
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-09-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.