Purpose: Fluoroscopic imaging remains the standard intraoperative imaging modality for volar locking plate fixation of distal radius fractures, and correlation with postoperative radiographs remains unclear. The purpose of this study was to assess the reliability of the Soong classification system between intraoperative fluoroscopy and postoperative radiographs for distal radius volar plate position.Entities:
Keywords: Distal radius fracture; Fluoroscopy; Soong classification; Volar plate position
Year: 2021 PMID: 35415591 PMCID: PMC8991425 DOI: 10.1016/j.jhsg.2021.09.002
Source DB: PubMed Journal: J Hand Surg Glob Online ISSN: 2589-5141
Figure 1A Grade 0: Plate is dorsal to critical line (red). B Grade 1: Plate is volar to critical line (red) but proximal to the volar rim. C Grade 2: Plate is volar to critical line (red) and on or distal to the volar rim.
Figure 2Kappa value reliability interpretation.
Intraobserver Reliability for Each Observer Group
| Observer Group | Fluoroscopy | X-ray | Overall | Fluoroscopy Versus X-ray | |||
|---|---|---|---|---|---|---|---|
| Kappa | 95% CI | Kappa | 95% CI | Kappa | 95% CI | ||
| PGY2 | 0.349 (0.180) | -0.004–0.701 | 0.468 (0.167) | 0.141–0.795 | 0.409 (0.122) | 0.170–0.648 | .63 |
| PGY3 | 0.488 (0.170) | 0.154–0.821 | 0.254 (0.195) | -0.129–0.636 | 0.360 (0.134) | 0.098–0.621 | .37 |
| PGY4 | 0.777 (0.100) | 0.581–0.973 | 0.560 (0.168) | 0.230–0.890 | 0.662 (0.112) | 0.443–0.881 | .27 |
| PGY5 | 0.579 (0.177) | 0.233–0.926 | 0.611 (0.160) | 0.298–0.925 | 0.602 (0.118) | 0.371–0.833 | .89 |
| Attending | 0.552 (0.240) | 0.081–1.022 | 0.708 (0.133) | 0.448–0.968 | 0.679 (0.142) | 0.401–0.957 | .57 |
| Overall | 0.553 (0.178) | 0.204–0.902 | 0.550 (0.160) | 0.236–0.865 | 0.564 (0.126) | 0.317–0.810 | .99 |
Reported as kappa (standard error).
Reported as lower and upper bounds of 95% CI.
Fluoroscopy and x-ray imaging combined.
All observers.
Intraobserver Reliability for Individuals
| Observer | Fluoroscopy | X-ray | Overall | |||
|---|---|---|---|---|---|---|
| Kappa | Standard Error | Kappa | Standard Error | Kappa | Standard Error | |
| DU_PGY2 | 0.633 | 0.19 | 0.791 | 0.14 | 0.719 | 0.116 |
| KB_PGY2 | 0.133 | 0.18 | 0.195 | 0.17 | 0.159 | 0.125 |
| ML_PGY2 | 0.28 | 0.17 | 0.418 | 0.19 | 0.349 | 0.125 |
| MW_PGY3 | 0.695 | 0.15 | 0.23 | 0.2 | 0.446 | 0.131 |
| HT_PGY3 | 0.28 | 0.19 | 0.277 | 0.19 | 0.273 | 0.136 |
| LT_PGY4 | 0.787 | 0.14 | 0.448 | 0.19 | 0.626 | 0.123 |
| TP_PGY4 | 1 | 0 | 0.635 | 0.16 | 0.788 | 0.1 |
| RM_PGY4 | 0.545 | 0.16 | 0.597 | 0.155 | 0.573 | 0.112 |
| JR_PGY5 | 0.378 | 0.19 | 0.572 | 0.15 | 0.488 | 0.122 |
| TH_PGY5 | 0.575 | 0.19 | 0.556 | 0.17 | 0.57 | 0.125 |
| TB_PGY5 | 0.785 | 0.15 | 0.706 | 0.16 | 0.748 | 0.107 |
| BT_Att | 1 | 0 | 0.843 | 0.15 | 0.886 | 0.11 |
| RC_Att | 0.286 | 0.33 | 1 | 0 | 0.805 | 0.127 |
| WF_Att | 0.545 | 0.36 | 0.614 | 0.19 | 0.607 | 0.168 |
| MR_Att | 0.375 | 0.27 | 0.375 | 0.19 | 0.417 | 0.162 |
Att, attending physician.
Standard error.
Fluoroscopy and x-ray imaging combined.
Interobserver Reliability for Each Observer Group
| Fluoroscopy | X-ray | Overall | Fluoroscopy Versus X-ray | ||||
|---|---|---|---|---|---|---|---|
| Kappa | 95% CI | Kappa | 95% CI | Kappa | 95% CI | ||
| PGY2 | 0.113 (0.054) | 0.007–0.219 | 0.105 (0.054) | -0.001–0.211 | 0.113 (0.038) | 0.039–0.187 | .91 |
| PGY3 | 0.155 (0.095) | -0.031–0.341 | 0.167 (0.093) | -0.015–0.349 | 0.168 (0.066) | 0.039–0.297 | .93 |
| PGY4 | 0.425 (0.059) | 0.309–0.541 | 0.048 (0.055) | 0.040–0.256 | 0.287 (0.040) | 0.208–0.365 | <.001 |
| PGY5 | 0.529 (0.060) | 0.411–0.647 | 0.434 (0.056) | 0.324–0.544 | 0.492 (0.040) | 0.414–0.570 | .25 |
| Attending | 0.619 (0.060) | 0.501–0.737 | 0.636 (0.056) | 0.526–0.746 | 0.629 (0.041) | 0.549–0.709 | .84 |
| Overall | 0.508 (0.014) | 0.481–0.535 | 0.396 (0.013) | 0.371–0.421 | 0.453 (0.009) | 0.435–0.471 | <.001 |
Reported as kappa (standard error).
Reported as lower and upper bounds of 95% CI.
Fluoroscopy and x-ray imaging combined.
All observers.
Kappa Values for Individual Soong Classification Categories
| Grade | Conditional Probability | Kappa | Asymptotic Standard Error | Z | Lower 95% Asymptotic CI Bound | Upper 95% Asymptotic CI Bound | |
|---|---|---|---|---|---|---|---|
| 0 | 0.681 | 0.527 | 0.012 | 42.139 | .00 | 0.502 | 0.551 |
| 1 | 0.714 | 0.411 | 0.012 | 32.914 | .00 | 0.387 | 0.436 |
| 2 | 0.506 | 0.412 | 0.012 | 32.959 | .00 | 0.387 | 0.436 |
| Overall | 0.453 | 0.012 | 48.547 | .00 | 0.435 | 0.472 | |