| Literature DB >> 35390023 |
Urusha Maharjan1, Sujata Rijal2, Ashutosh Jnawali3, Sanjeeta Sitaula4, Sanjeev Bhattarai4, Gulshan Bahadur Shrestha4.
Abstract
PURPOSE: To determine the binocular vision status in normally-sighted school aged children who used digital devices.Entities:
Mesh:
Year: 2022 PMID: 35390023 PMCID: PMC8989299 DOI: 10.1371/journal.pone.0266068
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Parameters of Binocular Vision (BSV) in non-users group.
| Parameters of BSV in non-users group | Current Study | Normative data taken from the BAND study [ | P-value |
|---|---|---|---|
| Stereo acuity | 51 ± 15.95 seconds of arc | 40 ± 15 seconds of arc | 0.20 |
| Monocular NPA (RE) (in centimeters) | 7–10 years: 6.50 ± 0.58 | 7–10 years: 13 ± 3 | <0.01* |
| 11–17 years: 6.40 ± 0.55 | 11–17 years: 11 ± 2 | <0.01* | |
| Binocular NPA (in centimeters) | 7–10 years: 6.50 ± 0.58 | 7–10 years: 13 ± 3 | <0.01* |
| 11–17 years: 6.40 ± 0.55 | 11–17 years: 11 ± 3 | <0.01* | |
| MAF (RE) (cycles per minute) | 7–12 years: 12.08 ± 1.79 | 7–12 years: 11 ± 4 | 0.55 |
| 13–17 years: 9.40 ± 2.33 | 13–17 years: 14 ± 5 | 0.04* | |
| BAF (cycles per minute) | 7–12 years: 12.30 ± 2.33 | 7–12 years: 10 ± 4 | 0.20 |
| 13–17 years: 9.00 ± 3.08 | 13–17 years: 14 ± 5 | 0.03* | |
| Lag of Accommodation | 0.13 ± 0.13 Diopters | 0.4 ± 0.2 Diopters | <0.01* |
| NPC (in centimeters) | 7.00 ± 1.41 | 3 ± 3 | <0.01* |
| PFV for distance (prism diopters) | 15.00 ± 4.24 | 17 ± 8 | 0.43 |
| PFV for near (prism diopters) | 25.00 ± 7.07 | 26 ± 10 | 0.75 |
| NFV for distance (prism diopters) | 9.14 ± 0.74 | 8 ± 2 | 0.71 |
| NFV for near (prism diopters) | 19.00 ± 1.41 | 15 ± 4 | <0.01* |
BAF = Binocular Accommodative Facility, LE = left eye, MAF = Monocular Accommodative Facility, NFV = Negative Fusional Vergence, NPA = Near Point of Accommodation, NPC = Near Point of Convergence, PFV = Positive Fusional Vergence, RE = right eye
Comparison of binocular vision findings of low digital device users subgroup with the normative data taken from the BAND study.
| Parameters of BSV | Low digital device users subgroup (n = 87) | Normative data Taken from the BAND study [ | |
|---|---|---|---|
| Stereo acuity | 52.35 ± 31.25 seconds of arc | 40±15 seconds of arc | <0.01 |
| Monocular NPA (RE) (in centimeters) | 7–10 years: 6.56 ± 0.78 | 7–10 years: 13 ± 3 | <0.01 |
| 11–17 years: 6.96 ± 1.50 | 11–17 years: 11 ± 2 | <0.01 | |
| Binocular NPA (in centimeters) | 7–10 years: 6.56 ± 0.78 | 7–10 years: 13 ± 3 | <0.01 |
| 11–17 years: 6.69 ± 1.12 | 11–17 years: 11 ± 3 | <0.01 | |
| MAF (RE) (cycles per minute) | 7–12 years: 10.62 ± 2.63 | 7–12 years: 11 ± 4 | 0.57 |
| 13–17 years: 10.91 ± 3.52 | 13–17 years: 14 ± 5 | <0.01 | |
| BAF (cycles per minute) | 7–12 years: 9.33 ± 2.49 | 7–12 years: 10 ± 4 | 0.32 |
| 13–17 years: 10.07 ± 3.50 | 13–17 years: 14 ± 5 | <0.01 | |
| Lag of Accommodation (diopters) | 0.43 ± 0.40 | 0.4 ± 0.2 | 1.62 |
| NPC (centimeters) | 7.08 ± 2.39 | 3 ± 3 | <0.01 |
| PFV for distance (prism diopters) | 16.01 ± 7.17 | 17 ± 8 | 0.25 |
| PFV for near (prism diopters) | 31.00 ± 10.89 | 26 ± 10 | <0.01 |
| NFV for distance (prism diopters) | 9.48 ± 3.55 | 8 ± 2 | <0.01 |
| NFV for near (prism diopters) | 14.19 ± 4.29 | 15 ± 4 | 0.06 |
* = p value less than 0.01.
Abbreviations: BAF = Binocular Accommodative Facility, LE = left eye, MAF = Monocular Accommodative Facility, NFV = Negative Fusional Vergence, NPA = Near Point of Accommodation, NPC = Near Point of Convergence, PFV = Positive Fusional Vergence, RE = right eye.
Comparison of high digital device users subgroup with the normative data taken from the BAND study.
| Parameters of BSV | High digital device users subgroup (n = 83) | Normative data taken from the BAND study [ | |
|---|---|---|---|
| Stereo acuity | 46.75 ± 14.21 seconds of arc | 40±15 seconds of arc | <0.01 |
| Monocular NPA (RE) (in centimeters) | 7–10 years: 7.29 ± 1.49 | 7–10 years: 13 ± 3 | <0.01 |
| 11–17 years: 7.69 ± 1.98 | 11–17 years: 11 ± 2 | <0.01 | |
| Binocular NPA (in centimeters) | 7–10 years: 7.21 ± 1.53 | 7–10 years: 13 ± 3 | <0.01 |
| 11–17 years: 7.64 ± 1.94 | 11–17 years: 11 ± 3 | <0.01 | |
| MAF (RE) (cycles per minute) | 7–12 years: 6.88 ± 3.57 | 7–12 years: 11 ± 4 | <0.01 |
| 13–17 years: 8.52 ± 3.36 | 13–17 years: 14 ± 5 | <0.01 | |
| BAF (cycles per minute) | 7–12 years: 6.76 ± 2.77 | 7–12 years: 10 ± 4 | <0.01 |
| 13–17 years: 8.20 ± 3.17 | 13–17 years: 14 ± 5 | <0.01 | |
| Lag of Accommodation (diopters) | 0.81 ± 0.26 | 0.4 ± 0.2 | <0.01 |
| NPC (centimeters) | 7.15 ± 2.43 | 3 ± 3 | <0.01 |
| PFV for distance (prism diopters) | 12.31 ± 6.30 | 17 ± 8 | <0.01 |
| PFV for near (prism diopters) | 21.87 ± 9.03 | 26 ± 10 | <0.01 |
| NFV for distance (prism diopters) | 8.59 ± 3.75 | 8 ± 2 | <0.01 |
| NFV for near (prism diopters) | 14.12 ± 5.36 | 15 ± 4 | 0.05 |
Abbreviations: BAF = Binocular Accommodative Facility, LE = left eye, MAF = Monocular Accommodative Facility, NFV = Negative Fusional Vergence, NPA = Near Point of Accommodation, NPC = Near Point of Convergence, PFV = Positive Fusional Vergence, RE = right eye
* = p value less than 0.01.
Binocular vision findings between low and high digital device users subgroup.
| Parameters of BSV | Low digital device users subgroup (n = 87) | High digital device users subgroup (n = 83) |
|
|---|---|---|---|
| Stereo acuity | 52.35 ± 31.25 seconds of arc | 46.75 ± 14.21 seconds of arc | 0.15 |
| Monocular NPA (RE) (in centimeters) | 7–10 years: 6.56 ± 0.78 | 7–10 years: 7.29 ± 1.49 | 0.46 |
| 11–17 years: 6.96 ± 1.50 | 11–17 years: 7.69 ± 1.98 | <0.01 | |
| Binocular NPA (in centimeters) | 7–10 years: 6.56 ± 0.78 | 7–10 years: 7.21 ± 1.53 | 0.45 |
| 11–17 years: 6.69 ± 1.12 | 11–17 years: 7.64 ± 1.94 | <0.01 | |
| MAF (RE) (cycles per minute) | 7–12 years: 10.62 ± 2.63 | 7–12 years: 6.88 ± 3.57 | <0.01 |
| 13–17 years: 10.91 ± 3.52 | 13–17 years: 8.52 ± 3.36 | <0.01 | |
| BAF (cycles per minute) | 7–12 years: 9.33 ± 2.49 | 7–12 years: 6.76 ± 2.77 | <0.01 |
| 13–17 years: 10.07 ± 3.50 | 13–17 years: 8.20 ± 3.17 | 0.02 | |
| Lag of Accommodation (diopters) | 0.43 ± 0.40 | 0.81 ± 0.26 | 0.03 |
| NPC (centimeters) | 7.08 ± 2.39 | 7.15 ± 2.43 | 0.99 |
| PFV for distance (prism diopters) | 16.01 ± 7.17 | 12.31 ± 6.30 | <0.01 |
| PFV for near (prism diopters) | 31.00 ± 10.89 | 21.87 ± 9.03 | <0.01 |
| NFV for distance (prism diopters) | 9.48 ± 3.55 | 8.59 ± 3.75 | 0.22 |
| NFV for near (prism diopters) | 14.19 ± 4.29 | 14.12 ± 5.36 | 0.94 |
*p value less than 0.05.
Abbreviations: BAF = Binocular Accommodative Facility, LE = left eye, MAF = Monocular Accommodative Facility, NFV = Negative Fusional Vergence, NPA = Near Point of Accommodation, NPC = Near Point of Convergence, PFV = Positive Fusional Vergence, RE = right eye.
Comparison of prevalence of accommodative and vergence anomalies between low and high digital device users subgroups.
| Type of anomaly | Frequency in low digital device users subgroup (n = 86) | Frequency in high digital device users subgroup (n = 82) | P value (Chi square) |
|---|---|---|---|
| AIF | 25 (29.07%) | 55 (67.10%) | 0.002 |
| AI | 14 (16.28%) | 26 (31.71%) | 0.004 |
| CI | 16 (18.60%) | 26 (31.71%) | 0.075 |
| FI | 43 (50%) | 59 (71.95%) | 0.006 |
*p value less than 0.01
Abbreviations: AI = Accommodative Insufficiency, AIF = Accommodative Infacility, CI = Convergence Insufficiency, FI = Fusional Insufficiency
(NOTE: The above mentioned frequencies are single count; thus, the total will not add up to total number of users group)