Literature DB >> 35385343

Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature.

Fiammetta Catania1,2, Emanuela Morenghi1,2, Pietro Rosetta3, Vinciguerra Paolo1,2, Riccardo Vinciguerra3.   

Abstract

PURPOSE: The aim of this meta-analysis of the literature is to provide a comprehensive analysis of the differences in Corvis ST dynamic corneal response (DCR) parameters between primary open-angle glaucoma (POAG) patients and healthy controls.
METHODS: A quantitative meta-analysis was conducted on articles published before September 10, 2021 identified by searching PubMed, EMBASE, and Web of Science. Prospective studies comparing DCR Corvis ST parameter in high tension POAG and healthy controls were included. The random-effects model was conducted. Assessment of heterogeneity was based on the calculation of I2. Funnel plots evaluation and meta-regression were performed in case of detection of high heterogeneity.
RESULTS: The selection process resulted in the inclusion of six articles. Pooled analysis revealed that POAG corneas respond to mechanical stimulus with a smaller concavity, showing lower deformation amplitude (DA) (CI95% -0.991 to -0.578; p < .001; I2 = 0%), higher highest concavity radius (HCR; confidence interval [CI]95% -0.01 to 0.34; p = .058; I2 = 6.7%), and lower peak distance (PD; CI95% -1.06 to -0.024; p = .040; I2 = 86.5%). They also show a slower loading phase, with lower highest concavity time (HCT; CI95% -0.39 to -0.02; p = .029; I2 = 3.3%) and lower applanation velocity-1 (CI95% -0.641 to -0.127; p = .003; I2 = 34.6%), and a faster restoration to the original form, shown by lower applanation time-2 (CI95% -1.123 to -0.544; p = .001; I2 = 44.8%) compared to healthy subjects.
CONCLUSIONS: High tension POAG patients are characterized by stiffer corneas compared to healthy controls. These differences are valid also after removing the effect of age, corneal thickness, and intraocular pressure (IOP).

Entities:  

Keywords:  Corvis ST; Glaucoma; POAG; corneal biomechanics; healthy controls

Year:  2022        PMID: 35385343     DOI: 10.1080/02713683.2022.2059809

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  1 in total

1.  Comparing corneal biomechanics and intraocular pressure between healthy individuals and glaucoma subtypes: A cross-sectional study.

Authors:  Reza Zarei; Mohammad Hossein Zamani; Yadollah Eslami; GHasem Fakhraei; Mehdi Tabatabaei; Amir Reza Esfandiari
Journal:  Ann Med Surg (Lond)       Date:  2022-09-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.