Literature DB >> 35380366

Evaluation of MU2net as an online secondary dose check for MR guided radiation therapy with the Elekta unity MR linac.

Ariadne S Shoobridge1,2, John A Baines3.   

Abstract

During the adaptive workflow associated with MRgRT, a secondary dose calculation is required and MU2net (DOSIsoft, France) is one commercial option. The suitability of MU2net to be used in conjunction with the online Monaco treatment planning system of the Elekta Unity (Elekta AB, Stockholm, Sweden), is evaluated in this work. Monaco and MU2net point doses are compared for various fields on and off axis and at different SSDs. To investigate the comparative effects of attenuation due to the cryostat, couch and posterior coil, measured, MU2net and Monaco dose outputs at the isocentre, as a function of gantry angle, were compared. Point doses for the beams of nine step and shoot IMRT (SSIMRT) test plans (courtesy Elekta) were calculated with Monaco v5.4 and compared to corresponding doses computed with MU2net. In addition, Monaco v5.4 and MU2net point doses were compared for 1552 beams treated on the Unity at our facility. For the on-axis fields investigated the agreement between MU2net and measured data is acceptable. MU2net and Monaco point doses for the Elekta SSIMRT test plans were within ± 5.0% and ± 6.4% for beams delivered from gantry zero and at planned beam angles, respectively. For the 1552 beams delivered approximately 80.0% of MU2net and Monaco point doses agree within ± 5.0%, therefore it is recommended to correlate MU2net Dose Reference Points (DRPs) with pre and post treatment dosimetry verification. Computational accuracy of MU2net could be enhanced with improved modelling of attenuation due to the couch, cryostat and posterior MR imaging coil.
© 2022. Crown.

Entities:  

Keywords:  Elekta unity; MR-Linac; MU2net; Secondary dose calculation

Mesh:

Year:  2022        PMID: 35380366     DOI: 10.1007/s13246-021-01085-0

Source DB:  PubMed          Journal:  Phys Eng Sci Med        ISSN: 2662-4729


  9 in total

1.  Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4.

Authors:  Syed Bilal Ahmad; Arman Sarfehnia; Moti Raj Paudel; Anthony Kim; Sami Hissoiny; Arjun Sahgal; Brian Keller
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Multichannel film dosimetry with nonuniformity correction.

Authors:  Andre Micke; David F Lewis; Xiang Yu
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

Review 3.  The magnetic resonance imaging-linac system.

Authors:  Jan J W Lagendijk; Bas W Raaymakers; Marco van Vulpen
Journal:  Semin Radiat Oncol       Date:  2014-07       Impact factor: 5.934

4.  Beam characterisation of the 1.5 T MRI-linac.

Authors:  S J Woodings; J J Bluemink; J H W de Vries; Y Niatsetski; B van Veelen; J Schillings; J G M Kok; J W H Wolthaus; S L Hackett; B van Asselen; H M van Zijp; S Pencea; D A Roberts; J J W Lagendijk; B W Raaymakers
Journal:  Phys Med Biol       Date:  2018-04-19       Impact factor: 3.609

5.  Assessment of image quality and scatter and leakage radiation of an integrated MR-LINAC system.

Authors:  Jihong Wang; Joshua Yung; Mo Kadbi; Ken Hwang; Yao Ding; Geoffrey S Ibbott
Journal:  Med Phys       Date:  2018-02-16       Impact factor: 4.071

6.  Development and validation of a 1.5 T MR-Linac full accelerator head and cryostat model for Monte Carlo dose simulations.

Authors:  M Friedel; M Nachbar; D Mönnich; O Dohm; D Thorwarth
Journal:  Med Phys       Date:  2019-10-08       Impact factor: 4.071

7.  MRI-guided tumor tracking in lung cancer radiotherapy.

Authors:  Laura I Cerviño; Jiang Du; Steve B Jiang
Journal:  Phys Med Biol       Date:  2011-05-31       Impact factor: 3.609

8.  Adaptive radiotherapy: The Elekta Unity MR-linac concept.

Authors:  Dennis Winkel; Gijsbert H Bol; Petra S Kroon; Bram van Asselen; Sara S Hackett; Anita M Werensteijn-Honingh; Martijn P W Intven; Wietse S C Eppinga; Rob H N Tijssen; Linda G W Kerkmeijer; Hans C J de Boer; Stella Mook; Gert J Meijer; Jochem Hes; Mirjam Willemsen-Bosman; Eline N de Groot-van Breugel; Ina M Jürgenliemk-Schulz; Bas W Raaymakers
Journal:  Clin Transl Radiat Oncol       Date:  2019-04-02

9.  Commissioning and performance evaluation of RadCalc for the Elekta unity MRI-linac.

Authors:  Stephen A Graves; Jeffrey E Snyder; Amanda Boczkowski; Joël St-Aubin; Dongxu Wang; Sridhar Yaddanapudi; Daniel E Hyer
Journal:  J Appl Clin Med Phys       Date:  2019-11-13       Impact factor: 2.102

  9 in total
  1 in total

1.  Commissioning measurements on an Elekta Unity MR-Linac.

Authors:  Marcus Powers; John Baines; Robert Crane; Chantelle Fisher; Stephen Gibson; Linda Marsh; Bronwyn Oar; Ariadne Shoobridge; Emily Simpson-Page; Marchant Van der Walt; Glenn de Vine
Journal:  Phys Eng Sci Med       Date:  2022-03-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.