Literature DB >> 35378858

Late onset cardiovascular dysfunction in adult mice resulting from galactic cosmic ray exposure.

Muath Bishawi1,2, Franklin H Lee1, Dennis M Abraham3, Carolyn Glass4, Stephanie J Blocker5, Daniel J Cox1, Zachary D Brown1, Howard A Rockman3, Lan Mao3, Tony C Slaba6, Mark W Dewhirst7, George A Truskey2, Dawn E Bowles1.   

Abstract

The complex and inaccessible space radiation environment poses an unresolved risk to astronaut cardiovascular health during long-term space exploration missions. To model this risk, healthy male c57BL/6 mice aged six months (corresponding to an astronaut of 34 years) were exposed to simplified galactic cosmic ray (GCR5-ion; 5-ion sim) irradiation at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratories (BNL). Multi-modal cardiovascular functional assessments performed longitudinally and terminally revealed significant impairment in cardiac function in mice exposed to GCR5-ion compared to unirradiated controls, gamma irradiation, or single mono-energetic ions (56Fe or 16O). GCR5-ion-treated mice exhibited increased arterial elastance likely mediated by disruption of elastin fibers. This study suggests that a single exposure to GCR5-ion is associated with deterioration in cardiac structure and function that becomes apparent long after exposure, likely associated with increased morbidity and mortality. These findings represent important health considerations when preparing for successful space exploration.
© 2022 The Authors.

Entities:  

Keywords:  Animal physiology; Cardiovascular medicine; Exposure; Model organism; Space medicine

Year:  2022        PMID: 35378858      PMCID: PMC8976132          DOI: 10.1016/j.isci.2022.104086

Source DB:  PubMed          Journal:  iScience        ISSN: 2589-0042


Introduction

Protected by the atmosphere as well as the magnetosphere, organisms living on the Earth do not encounter high levels of radiation from the space environment (Galactic Cosmic Rays [GCR] or Solar Particle Events [SPE]). Exploration to the Moon and Mars is expected to send humans beyond these protective barriers, for periods of months to years. While astronauts can be effectively shielded from most SPE exposures, highly energetic and complex GCR are difficult to shield and are considered a significant health risk for long-term exploration missions (Moeller et al., 2017). GCR consists primarily of high-energy protons and helium as well as a spectrum of high energy and charge (HZE) particles, such as 56Fe and 16O (Moeller et al., 2017). Exposures are predicted to occur at low fluence rates, with each cell in an astronaut’s body being traversed by a proton every few days, by a helium nucleus every few weeks, and by a HZE nucleus once every few months, for a total dose of 0.3–0.6 mGy/day.(Nelson, 2016). Biological concerns associated with this environmental stress include cognitive and neurological dysfunction, carcinogenesis, immunological impairment, and cardiovascular degeneration (Cucinotta et al., 2011, 2017; Cucinotta, 2014; Parihar et al., 2015). Modeling the impact of GCR exposure on the cardiovascular system has proven exceedingly difficult (Davis et al., 2021). Clinical and epidemiologic data obtained from studies of survivors of nuclear accidents, atomic bomb exposure, and radiation-based medical treatments have demonstrated that acute radiation exposure is associated with a higher rate of delayed cardiovascular-related morbidity and mortality (Ledsome, 2001; Taddeo and Armstrong, 2008; Baker et al., 2011; Adams et al., 2017; ; Abdelgawad et al., 2021). These studies are limited by confounding factors such as cancer comorbidity, follow-up time post radiation exposure, and estimations of radiation dose. Furthermore, none of these studies evaluate the effects of space radiation, and its unique characteristics, specifically. Trying to understand the cardiovascular risk of space radiation exposure from astronaut data is also problematic because only 24 Apollo lunar astronauts have traveled beyond low earth orbit (LEO) into the complex space radiation environment. Of those individuals who have traveled beyond LEO, the amount of time spent there has been less than 50 days (Delp et al., 2016; Elgart et al., 2018). Despite being inside LEO, the recent NASA twin study demonstrated that, in comparison to the twin on Earth, the twin who inhabited the International Space Station for one year developed both genetic modifications (altered telomere length and DNA methylation) and markers of increased cardiovascular risk (carotid intima-media thickening and increase in the APOB/APOA1 ratio) (Garrett-Bakelman et al., 2019). However, the contribution of GCR to these complications is unclear, as such effects may be due to other stressors, such as microgravity. Several investigations using the particle accelerator at BNL to deliver individual components of GCR (single mono-energetic ions such as protons, 56Fe or 16O) to healthy rodents have demonstrated only very minor changes in cardiac function at long-term endpoints. (Xinhua Yan et al., 2014b; Seawright et al., 2019). More sophisticated experimental design in which the sequence of fractionated doses of individual GCR components given over several days revealed dramatically different cardiovascular responses depending on the order of component delivery (Sasi et al., 2017; Seawright et al., 2019). Recent technology development in engineering and physics at NSRL can now simulate the complex GCR environment over a short period of time to enable investigators to overcome the challenges associated with indirect assessment of possible GCR effects in the heart (Norbury et al., 2016; Simonsen et al., 2020). In our investigation, six-month- old C57BL/6 male mice were exposed to single mono-energetic ions or a simplified 5-ion GCR radiation protocol (referred to as GCR5-ion at NSRL), and longitudinal cardiac phenotyping was performed throughout the course of the study. Phenotyping strategies included transthoracic echocardiography (TTE), cardiac MRI (cMRI), and terminal pressure- volume loop assessment (PVL). It was hypothesized that exposure to simulated space radiation (GCR5-ion) would result in increased deterioration of cardiac function compared to single mono-energetic ion exposures. This analysis demonstrates deterioration of cardiovascular function as reflected in histological and hemodynamic assessments one year after a single exposure to GCR5-ion whole body radiation. These perturbations may allude to the development of clinically diagnosable cardiovascular disease with further exposure to GCR or longer time post exposure.

Results

Overall study design

The overall experimental design is provided in Figure 1. Prior to irradiation, c57BL/6 mice underwent baseline cardiac functional screening using transthoracic echocardiography (TTE). The mice were transported to BNL and, when at approximately 6 months of age, were exposed to the following radiation conditions: (a) 50, 100, or 200 cGy 137Cs Gamma (0.662 MeV), (b) 15, 25, or 50 cGy 16O (600 MeV/n), (c) 15, 25, or 50 cGy 56Fe (1,000 MeV/n), or (d) 150 cGy GCR5-ion (H 1000 MeV/n, 28Si 600 MeV/n, 4He 250 MeV/n, 16O 350 MeV/n, 56Fe 600 MeV/n, and H 250 MeV/n) (Simonsen et al., 2020). Following radiation, exposed mice and age-matched unirradiated controls were returned to the home institution where cardiovascular measurements were acquired over time (Figures 1B–1D). Table S1 summarizes the study according to the number of animals evaluated by TTE, cMRI, or PVL and by radiation type and radiation dose.
Figure 1

Overall experimental design

(A) Experimental set up included c57BL/6 mice undergoing radiation at six months of age with sham radiation controls These included 137Cs Gamma radiation with an escalating dose 50–200cGy, 16O (15–50cGy) 600 MeV/n, 56Fe (15–50cGy) 1,000 MeV/n, and galactic cosmic rays (GCR5-ion) (150 cGy that included H 1000 MeV/n, 28Si 600 MeV/n, 4He 250 MeV/n, 16O 350 MeV/n, 56Fe 600 MeV/n, H 250 MeV/n). Detailed list of mouse per exposure type, dose, and assessment modality available in Table S1. One year post radiation assessments of cardiac function included the following: (B) awake echocardiography acquisition of M-mode images, B-mode, and Doppler images not depicted; (C) sedated cardiac MRI without contrast; (D) terminal pressure-volume loop assessment and analysis; (E) and cardiac/aortic histology analysis of H&E and MT stained sections.

Overall experimental design (A) Experimental set up included c57BL/6 mice undergoing radiation at six months of age with sham radiation controls These included 137Cs Gamma radiation with an escalating dose 50–200cGy, 16O (15–50cGy) 600 MeV/n, 56Fe (15–50cGy) 1,000 MeV/n, and galactic cosmic rays (GCR5-ion) (150 cGy that included H 1000 MeV/n, 28Si 600 MeV/n, 4He 250 MeV/n, 16O 350 MeV/n, 56Fe 600 MeV/n, H 250 MeV/n). Detailed list of mouse per exposure type, dose, and assessment modality available in Table S1. One year post radiation assessments of cardiac function included the following: (B) awake echocardiography acquisition of M-mode images, B-mode, and Doppler images not depicted; (C) sedated cardiac MRI without contrast; (D) terminal pressure-volume loop assessment and analysis; (E) and cardiac/aortic histology analysis of H&E and MT stained sections.

The effect of different forms of radiation on cardiac function as assessed by transthoracic echocardiography (TEE)

To mimic conditions of assessment in astronauts, we performed conscious transthoracic echocardiography on all mice (Table S1). 24 echocardiography measurements were read or calculated for each animal, and measurements from animals in each radiation condition were compared to unirradiated controls (Table S2). Three experimental groups, GCR5-ion (Figure 2 and Table S3), 56Fe (Figure S1 and Table S4), and 16O (Figure S2 and Table S5), demonstrated statistically significant changes in the echocardiographic measure of cardiac function as assessed by fractional shortening (FS) and calculated ejection fraction (EF). Both these measures of systolic function were elevated in a small but statistically significant manner in GCR5-ion-exposed animals (Figures 2A and 2B). Additionally, a small but statistically significant elevation in heart rate was observed in GCR5-ion-exposed animals compared to unirradiated controls after one year (Figure 2C). Measures of early and late diastolic function (E/A, IVRT, E′) were not statistically different between GCR-treated animals and controls (Figures 2D–2F), nor were they different in animals exposed to 56Fe, 16O, or Gamma (Figures S1–S3, respectively). Differences in systolic function and heart rate (HR) in GCR5-ion-exposed animals, while significant, were modest and of unclear physiological relevance. For instance, the median difference in percent FS between GCR5-ion and unirradiated controls was −2.8 (95% CI -5.4 to −0.36). The same was true for EF, with a median difference of −3.4 (95% CI -6.1 to −0.30). There were also minimal differences in HR and systolic functional assessments between age control animals, and those exposed to 56Fe (Figures S1A–S1C), 16O (Figures S2A–S2C), or Gamma (Figures S3A–S3C), at one year post radiation. This was also true for measures of diastolic function from mice exposed to 56Fe, 16O, or Gamma radiation, respectively (Figures S1–S3D, S3E, and S3F).
Figure 2

Echocardiographic measurements of unirradiated age-matched control and 150 cGy GCR5-ion-treated animals one year post radiation

Fractional shortening (A), ejection fraction (D), heart rate (C), early to late filling of mitral inflow (D), isovolumetric relaxation time (E), and passive LV filling (F). N = 17 for controls, and N = 34 for GCR5-ion animals. Nonparametric Mann-Whitney test, 2 sided. ∗p ≤ 0.05, ∗∗p ≤ 0.01. Data are represented as mean ± SEM.

Echocardiographic measurements of unirradiated age-matched control and 150 cGy GCR5-ion-treated animals one year post radiation Fractional shortening (A), ejection fraction (D), heart rate (C), early to late filling of mitral inflow (D), isovolumetric relaxation time (E), and passive LV filling (F). N = 17 for controls, and N = 34 for GCR5-ion animals. Nonparametric Mann-Whitney test, 2 sided. ∗p ≤ 0.05, ∗∗p ≤ 0.01. Data are represented as mean ± SEM. To further characterize in vivo changes in cardiac structure and function associated with GCR5-ion radiation, a subset of animals underwent preclinical cMRI evaluation (Figure S4). cMRI imaging including temporal “heart movie” acquisitions, providing images of the heart at 12 time points per cardiac cycle. While there appears to be no difference in stroke volume (SV) and LV thickness during systole, a small difference was detected in end-diastole LV thickness of GCR5-ion animals compared to controls (difference of 0.13mm, 95% CI -0.24 to −0.01, p = 0.032) (Figure S4C). However, when the same measurements were made during systole, no difference was seen between the groups. Further, when comparing the dynamic change in LV wall thickness from systole to end-diastole, no trends appeared between GCR5-ion -exposed and control animals. Finally, changes in cardiac volumes across the cardiac cycle between the groups appeared to be similar (Figure S4E).

Cardiac pressure-volume loop (PVL) analyses reveal decreased systolic function and increased arterial elastance one year after GCR5-ion but not after 56Fe, 16O, or Gamma radiation exposure

Hemodynamic assessment via pressure-volume loop (PVL) analysis is considered the gold standard for evaluating load-dependent and -independent measures of cardiac contractile function (Abraham and Mao, 2015). At one year post radiation, a subset of animals from each study group (GCR5-ion, 56Fe, 16O, Gamma, and control) underwent cardiac evaluation using cardiac PVL analyses (Table S7 lists all PVL parameters measured or calculated; Tables S8 and S9 lists average PVL parameter values for 150 cGy GCR5-ion and single mono-energetic ion cohorts, respectively). Mice that had been exposed to 150 cGy of GCR5-ion demonstrated significant diminishment in load-dependent measures of cardiac function, including stroke work (SW) (Figure 3A), stroke volume (SV) (Figure 3B), and cardiac output (CO) (Figure 3C). Of note, some load-dependent measure of systolic function (dP/dt max and Ejection Fraction) was not significantly different between GCR5-ion and unirradiated control (Figures 3D and 3E). However, the load-independent measurement, preload recruitable stroke work (PRSW), was significantly reduced in GCR5-ion-exposed animals (Figure 3F). In this instance, the median difference of PRSW between GCR5-ion and unirradiated control was −25.21% (95%CI, −48.41% to −11.74%). Early diastolic filling time, quantified by Tau, was not different between the groups (Figure 3G). Peripheral vascular resistance, measured by arterial elastance (Ea), was significantly increased in GCR5-ion-treated animals as compared to controls (Figure 3H). Echocardiography characteristics of PVL-evaluated mice were compared to that of the larger cohort, showing similar echocardiography characteristics between the two groups (Figure S5).
Figure 3

Pressure-volume loop (PVL) hemodynamic measurements of age-matched unirradiated control and GCR5-ion-treated c57BL/6 mice one year post radiation

Stroke work (A), stroke volume (B), cardiac output (C), ejection fraction (D), changes in LV pressure over time (E), preload recruitable stroke work (F), left ventricular relaxation time constant (G), and arterial elastance (H). N = 8 for controls, and 9–10 for GCR animals. Nonparametric Mann-Whitney test, 2 sided. ∗p ≤ 0.05, ∗∗p ≤ 0.01. Data are represented as mean ± SEM.

Pressure-volume loop (PVL) hemodynamic measurements of age-matched unirradiated control and GCR5-ion-treated c57BL/6 mice one year post radiation Stroke work (A), stroke volume (B), cardiac output (C), ejection fraction (D), changes in LV pressure over time (E), preload recruitable stroke work (F), left ventricular relaxation time constant (G), and arterial elastance (H). N = 8 for controls, and 9–10 for GCR animals. Nonparametric Mann-Whitney test, 2 sided. ∗p ≤ 0.05, ∗∗p ≤ 0.01. Data are represented as mean ± SEM. Despite the robust impact on cardiac function as measured by PVL, GCR5-ion exposure did not significantly alter mortality (Figure S6) or other general indicators of overall health such as blood pressure (Figures S7A–S7C) or weight (Figure S7D) compared to controls at 1 year post radiation. In contrast to the GCR5-ion-irradiated animals, no meaningful differences in systolic or diastolic performance from PVL analysis (SW, SV, CO, EF, dP/dTmax, PRSW, Tau, or Ea) were noted during the one-year analysis post 50 cGy 56Fe, 50 cGy 16O, or 200 cGy Gamma radiation compared to age-matched controls (Figure S8).

GCR radiation associated with changes in aortic elastic fiber organization

The PVL evaluation of GCR5-ion mice suggested enhanced peripheral vascular resistance and no significant differences in cardiac morphology. To correlate these functional studies caused by GCR5-ion exposure with anatomic and cellular changes, heart and aortic tissues from a subset of animals receiving GCR5-ion and controls underwent histological evaluation. While there was no significant change in cardiac fibrosis between groups (data not shown), evaluation of the thoracic aorta revealed an overall increase in medial necrosis, medial degeneration, elastin fragmentation, and architectural distortion (Figure 4). In particular, GCR5-ion mice exhibited a higher average grading of medial necrosis, elastin fragmentation, and architectural distortion (Figures 4A, 4C, and 4D), but showed lower average grading for medial degeneration (Figure 4B). Masson trichrome (MT)-stained mouse aortas exposed to GCR5-ion showed signs of elastin fragmentation (Figure 4E and 4F) while unirradiated age-matched control did not have any observable instances (Figure 4G).
Figure 4

Average histological grading and aortic Masson trichrome staining of 150 cGy GCR5-ion compared to GCR controls one year post radiation

Medial necrosis (A), medial degeneration (B), elastin fragmentation (C), and architectural distortion (D), 150cGy GCR5-ion mouse aortas (E, F), and GCR control (G). Solid black arrows point to areas of focal elastin fragmentation (E, F). Bridging between elastin fibers depicted by dotted black arrows (G). N = 11 for 150cGy GCR5-ion and N = 8 GCR controls. Data are represented as mean ± SEM.

Average histological grading and aortic Masson trichrome staining of 150 cGy GCR5-ion compared to GCR controls one year post radiation Medial necrosis (A), medial degeneration (B), elastin fragmentation (C), and architectural distortion (D), 150cGy GCR5-ion mouse aortas (E, F), and GCR control (G). Solid black arrows point to areas of focal elastin fragmentation (E, F). Bridging between elastin fibers depicted by dotted black arrows (G). N = 11 for 150cGy GCR5-ion and N = 8 GCR controls. Data are represented as mean ± SEM.

Western Blot (WB) analysis of heart apex tissue reveal changes in cardiac markers 1 year post-GCR5-ion radiation exposure

Heart apex tissue of 150 cGy GCR5-ion-irradiated mice and unirradiated age-matched controls were screened for the following cardiac markers: Fibulin-4, Fibulin-5, TGF-β1, and eGFR (Figures S10 and S11). Fibulin-4, Fibulin-5, and eGFR expression in GCR5-ion-irradiated mice were decreased compared to age-matched unirradiated control; eGFR was the only marker that showed a statistically significant decrease compared to controls. On the contrary, TGF-β1 expression was increased in GCR5-ion-irradiated mice when compared to age-matched unirradiated controls, which was not statistically significant.

Discussion

We report changes in resting load-dependent and -independent measures of cardiac function, as well as resting arterial elastance, one year after exposure of mice to GCR5-ion radiation. Further, changes in arterial elastance appear to be related to long-term damage in aortic elastin fibers. Reduced cardiac contractility and increased peripheral vascular resistance, key hemodynamic altertions in human congestive heart failure, can result from one exposure of GCR5-ion radiation. There have been several animal studies that simulated the effect of terrestrial and space radiation scenarios on cardiac function (Monceau et al., 2013; X. Yan et al., 2014a; Hughson et al., 2018; Seawright et al., 2019). However, available studies to date have been limited by short follow-up times and methods for evaluating cardiac function preclinically. In addition, no study has evaluated the effects of the complex radiation scenarios that are likely to be experienced during extended periods in space, such as GCR. To study this unique radiation environment, particle accelerators have been used to generate single mono-energetic ion beams at fixed energies; however, space radiation is much more complex, with a mixture of ion species and energies. Recently, GCR simulation became possible at NSRL, enabling the current report (Simonsen et al., 2020). In this study, we utilized multiple modalities to assess cardiac function in mice (TTE, PVL, and cMRI), one year after exposure to GCR5-ion. We chose a comprehensive approach for cardiac evaluation, understanding the limitations of each test and the need to compare measures across modalities for validation. While transthoracic echocardiography is frequently employed in mouse studies, it may lack the sensitivity required to reveal the impact of space radiation on cardiovascular function (Sato et al., 2001; Hughson et al., 2018). A review of the literature revealed two common pitfalls. First, most studies used healthy wild-type mice and sedated echocardiography as the primary method of cardiac assessment. These experiments may be affected by the cardiodepressant properties of sedation. Second, many prior studies used only one echocardiography reader or unclear prior internal validation of reads. This becomes a problem when faced with the large variability encountered in mouse echocardiograms (Gao et al., 2011). We performed echocardiograms on conscious mice, which were then analyzed independently by two clinicians blinded to exposure conditions. Despite identifying large and clinically meaningful differences in cardiac function after GCR5-ion using PVL testing, echocardiography was unable to discriminate between groups. This may explain inconsistencies in the current preclinical literature when echocardiography is used as the primary method of cardiac functional assessment. Given the known effect of anesthesia on cardiac function, we did not employ anesthesia for echocardiography (Gao et al., 2011). This is an important divergence from the majority of reports today, in which echocardiography is performed under sedation (Hughson et al., 2018). Isoflurane induces a negative inotropic effect on cardiac function (Gao et al., 2011), which may mask subtle differences related to the treatment. Although GCR5-ion -exposed animals exhibited statistically significant elevation of FS and EF (Figures 2A and 2B), we determined that the force-frequency effect, a known contributor to cardiac function, was not the likely cause after plotting FS against FS/HR (Figure S9). As GCR5-ion -exposed animals’ values did not diverge from that of their respective controls, we suggest that the elevation observed in FS and EF was due to differing loading conditions between groups, possibly related to higher fluid intake. Pressure-volume testing demonstrated consistent changes in measures of load-dependent and -independent systolic function for GCR5-ion -exposed animals after one year. The reduction in hemodynamically related load-dependent measures of stroke volume, stroke work, and cardiac output could be explained by an increase in afterload (elevated arterial elastance) and a reduction in contractility (decreased preload recruitable stroke work). In light of these findings, the apparent lack of effect of GCR5-ion on peripherally measured tail cuff blood pressures could be explained by the combined effects of increased peripheral vascular resistance (raises blood pressure) and reduced cardiac contractility (reduces blood pressure). The observed changes in arterial elastance in GCR5-ion-exposed animals correspond to clinical studies that demonstrate arterial stiffness after radiation exposure in humans (Gujral et al., 2016). Furthermore, the alterations in arterial elastance could be explained by disruption of arterial elastic fiber integrity (Yanagisawa and Wagenseil, 2019) and organization for the GCR5-ion-exposed animals as compared to age-matched control animals. While aging is associated with measurable changes in the integrity of aortic elastic fibers (Fhayli et al., 2020), GCR5-ion animals demonstrated significant deterioration 1 year post exposure, even when age was considered with matched controls. Elastic fiber integrity is critical for the Windkessel effect, a necessary process for blood pressure regulation and secondary organ blood flow (Belz, 1995). Taken together, these data suggest that astronauts exposed to GCR may suffer damage to both vascular and cardiac tissues that may predispose them to conditions such as congestive heart failure. Western blot analysis of cardiac markers in heart apexes from GCR5-ion-irradiated mice showed changes in protein expression, suggestive of changes in the extracellular matrix of the heart tissue. In particular, decreased eGFR expression, which is implicated in TGF-β1-mediated fibrosis, may explain the lack of fibrosis seen on histological assessment of GCR5-ion-irradiated mice heart tissue. To provide further insight into the molecular changes post GCR5-ion irradiation, a proteomics analysis of heart tissue and plasma is currently in progress. In this study, we report maladaptive changes in cardiac structure and function one year after exposure to GCR5-ion compared to age-matched controls. These effects were only seen in GCR5-ion -exposed animals, and were not found in animals exposed to single mono-energetic ion or gamma radiation. NASA estimates that a trip to Mars and back to Earth would expose the astronauts to a total accumulated dose of 50–75 cGy of GCR irradiation. We acknowledge using a GCR dose of 150 cGy, which is about 2 times the maximum dose that is estimated, an astronaut will be exposed to in future deep space missions. While these doses used in the study were higher than the dose expected during mission, the doses were reviewed and approved by NASA. The intention of the current study was not to quantify risks in an animal model and directly use this information for decision making for space exploration. Rather, the information reported here will be integrated with other experiments as well as with human epidemiology data in order to develop a full understanding as well as quantitative risk models. These findings have important implications for current and future plans of deep space exploration by NASA. Because we found a deterioration in cardiac structure and function after a single exposure to GCR, a reasonable approach to prolonged human space flight would be for astronauts to have an assessment of cardiac function by echocardiography and/or cMRI, prior to, immediately after, and several months following space flight. High-resolution noninvasive cardiac imaging before and after space travel would likely be best carried out as a clinical trial testing whether brief or prolonged space travel affects short or long-term cardiac function and cardiopulmonary functional capacity.

Limitations of the study

This was also the first report to use cMRI to evaluate cardiac structure and function post exposure to space radiation. cMRI provides unique opportunities for assessing a number of cardiac functional and structural characteristics (Gardner et al., 2009). Two important limitations with our early cMRI studies were the small group size and the lack of contrast agent. The latter, while not prohibitive, can reduce the accuracy of measurements due to lower contrast at the blood-to-wall boundary, particularly during diastole. Because of these considerations, preclinical cMRI may still represent a sensitive means of understanding murine cardiac structure and function post space radiation in healthy animals and this methodology may prove useful in future should we identify a group which shows the largest differences in echo.

STAR★Methods

Key resources table

Resource availability

Lead contact

Further information and requests for resources (such as mouse tissue requests) should be directed to the lead contact, Dawn E. Bowles, Ph.D. (dawn.bowles@duke.edu).

Materials availability

This study’s biobanked mouse organs are stored within the Bowles Lab at Duke University

Experimental model and subject details

Experimental animals

All animal experiments were approved by the Duke University and Brookhaven National Laboratories’s Institutional Animal Care and Use Committees (IACUCs). Approximately 24 week old C57BL/6 male mice (Jackson Laboratories) underwent baseline echocardiograms at Duke University before transfer to NSRL at BNL for radiation experiments. Mice were housed together with their littermates at all times throughout the study. They were allowed an acclimation period of 2–4 days a few days prior to radiation exposure. Some mice were exposed to gamma radiation using the J. L. Shepherd Mark I Model 68A 137Cs Gamma irradiator at BNL. Other animals were exposed to 16O (600 MeV/n), 56Fe (1,000 MeV/n), or GCR5-ion using the beam line at NSRL. Finally, control animals were placed in equitable radiation holders over a schedule, which mimicked the experimental groups. Since GCR5-ion exposure took a longer period of time than single mono-energetic ions, a set of age matched GCR5-ion controls were created that are analyzed separately from the single mono-energetic ion or gamma controls. Post-radiation, animals were allowed at least 2 days to recover, and then were returned to Duke University animal facilities where they underwent their longitudinal cardiac assessments.

Method details

Transthoracic echocardiograms

All echocardiograms were performed at the Duke Cardiovascular Physiology Core using a VisualSonics Vevo3100 echocardiography machine with 30 mHz probe and analyzed using Vevo Lab software (version 5.2.6). Prior to obtaining baseline TTE, mice were pre-conditioned the day before by being held in the same manner during shaving as they would be held during the echocardiogram, to decrease stress during the procedure. Next, mice underwent conscious echocardiography by an experienced technologist. All echocardiogram images were assigned a code based on experimental group and uploaded to a centralized server. To ensure rigor and reproducibility, each echocardiogram was interpreted by two independent blinded experienced readers, and their readings were averaged to give a final value. To ensure accuracy, interobserver differences in fractional shortening were assessed amongst all treatment arms and these differences were found to be normally distributed. A “significant” discrepancy was defined as interobserver difference that was greater than two standard deviations from the mean interobserver difference, which was found in 10% of all echocardiograms. Studies with a significant discrepancy between two readers underwent a third analysis by another reader, and the final value is a reflection of three reads. The parameters that were measured on echocardiograms are listed in Table S2.

Pressure-volume loop (PVL) assessments

A subset of animals underwent PVL assessment. All PVL procedures and analyses were performed at the Duke Cardiovascular Research Center by an experienced microsurgeon based on methods reported in the literature (Yoo et al., 2009; Abraham et al., 2016, 2018). Parallel conductance (Vp) of the blood pool was determined by 10-μL injection of 15% saline into the right jugular vein. The derived Vp was used to correct the pressure-volume loop data. Data were recorded digitally at 1,000 Hz and analyzed with pressure-volume analysis software (PVAN data analysis software version 3.3; Millar Instruments). Mice that died after receiving anesthesia or became hypotensive during the course of the protocol, suggesting a surgical complication (LV rupture, bleeding, arrhythmias), were excluded. A small laparotomy was performed, and the inferior vena cava occluded to decrease preload to the heart in order to measure load independent parameters. After completion of the PVL measurements, the animals were euthanized, tissue isolated, and bio preserved as described previously (Brown et al., 2020). Analysis and interpretation of the PVLs was done by DA.

Cardiac MRI (cMRI) & image analysis

All cMRI evaluations were performed at the Duke Center for In Vivo Microscopy. Imaging was performed on a 7.0 T Bruker Biospec small animal MRI scanner (Bruker Inc., Billerica, MA). Animal anesthesia was induced and maintained with inhaled isoflurane (0.5–2.0%), and breath rate was monitored for the duration of the scans. Animals were positioned on a custom 3D-printed bed and body temperature was maintained with warm water circulation. The animals were maintained on isoflurane for less than an hour, to reduce drops in cardiac function as a result of prolonged sedation. The animals were recovered after the completion of cMRI image acquisition. Images were acquired with ParaVision® 6.0.1 platform (Bruker Inc.) using a 4-channel surface coil array (inverted mouse brain coil) combined with a 72mm diameter actively decoupled linear volume coil for transmission. Cardiac time-course images were acquired using an intra-gated multi-slice T1-weighted cine FLASH sequence (TE/TR = 2.0/88.6 ms; 0.1 × 0.1 × 0.8 mm voxel size; 8 slices; 12 frames/cardiac cycle), with the addition of a bright-blood pulse to enhance blood pool signal without the need for an injected contrast agent. Slice orientation was adjusted to take serial slices perpendicular to the long axis of the heart, such that the 0.1 mm2 in plane slices demonstrated cross-sections of the LV, which was verified by a cardiac clinician (MB). Images were analyzed using 3D Slicer open source image analysis software (www.slicer.org), as well as Image J (https://imagej.nih.gov). At each time point throughout the cardiac cycle, LV volume was measured by manual segmentation of each slice. Cardiac wall thickness was measured using Image J, with the location standardized using the papillary muscles. Linear distances were measured in six radial positions across the LV at peak systole and diastole, and all measurements were performed in triplicate to assess measurement precision.

Tissue histology

Mice were euthanized through a bilateral thoracotomy and secondary exsanguination. A gravity perfusion rig was set up by elevating a flask containing 4% PFA to a height of ∼150cm above the mouse body. The flask was connected to tubing fitted with a 22G hypodermic needle at the end. While the heart was still beating, the needle was inserted in situ into the left ventricle to a depth of ∼5mm and 4% PFA was allowed to flow. Perfusion was continued until blanching of the heart and liver and contraction of skeletal muscle was observed. Hearts and aortas were then excised and left for further fixation overnight in 4% PFA at 4°C. The following day, all samples were transferred into PBS pH 7.4 and sent to Duke Pathology Research Immunohistology Lab for paraffin embedding, transverse (short axis) 5μm serial sectioning, and Hematoxylin & Eosin (H&E) and Masson Trichrome staining (MT). A board-certified, cardiac fellowship trained surgical pathologist (CG) evaluated all H&E and corresponding MT stained slides in a de-identified fashion. All histologic sections were reviewed for the absence or presence of aortic medial necrosis (defined histologically by disruption of collagen, dropout of smooth muscle cell nuclei and increased basophilic ground substance), medial degeneration, and elastin fragmentation (defined histologically by a disruption in the organized, linear architecture of the parallel elastic fibers within the wall of the aortic medial layer) and architectural distortion. All histologic sections were reviewed for the absence or presence of common disorders in cardiac and aortic pathology, which includes endocardial, interstitial, or replacement fibrosis, active myocarditis, granulomatous inflammation, amyloidosis, myocyte disarray, myocardial infarction, aortic dissection, or accelerated atherosclerosis.

Western Blot & densitometric analysis

Heart apex samples were homogenized using a glass dounce in 300 μL of TBST + proteinase inhibitor solution. All samples were centrifuged at 13,000 rpm in a microcentrifuge for 10 min. Supernatants were carefully transferred to clean microcentrifuge tubes and protein content quantified using a BCA assay (Thermo Fisher Scientific). For each sample, 60 μg of protein were loaded per well into stain-free 4–20% Tris-Glycine polyacrylamide gels (Bio-Rad). Two lanes of Thermo Fisher SpectraTM Multicolor Broad Range Protein Ladder were also loaded such that they flanked the samples. Gels were run at 100V for 75 min or until the the dye-front reached the marker on the gel cassette. 0.2 μm PVDF membranes were soaked in ice-cold 100% MeOH for 3 min and then transferred to a 10% MeOH Transfer Buffer. Filter paper and sponges were also presoaked in Transfer Buffer while the gel was running. Gel with protein was equilibrated in ice-cold 10% MeOH Transfer Buffer for 10 min before assembling in a wet-transfer tank with the PVDF membrane, filter paper, and sponges. Proteins were transferred to the membrane at 30V for 30 min in 10% MeOH Transfer Buffer. Post-transfer, the membrane was incubated in 2.5% non-fat milk (w/v) in TBST overnight at 4°C. The gel was imaged using Bio-Rad’s stain-free technology and ChemidocTM MP imager to determine if protein transfer was sufficient, indicated by an absence of visible bands on the gel. Indirect detection was implemented for probing the blot for protein using the following primary antibodies: anti- Fibulin 4 (Thermo Fisher | BS-13059R), Fibulin-5 (Thermo Fisher | 12188-1-AP), TGF-β1 (Abcam | ab215715), eGFR (Abcam | ab52894), and TBP (Abcam | Ab220788). All primary antibodies used the same secondary antibody, goat HRP conjugated anti-Rabbit IgG (Bio-Rad | 1706515). Primary antibodies and secondary antibody were incubated at RT for 2 h and 1 h, respectively, in 2.5% non-fat milk TBST with 45 rpm shaking. In between antibody incubations, blots were washed three times 10 min each with 10 mL of TBST with 45 rpm shaking at RT. Blots were visualized using Clarity Max ECL detection reagent (Bio-Rad). Blots were washed with 10 mL of TBST as mentioned above and incubated with detection reagent for 5 min at RT with 45 rpm shaking. Blots were visualized for colorimetric detection of protein ladders and chemiluminescent detection of probed targets. Blots were stripped of antibodies by incubating at 37°C with 30 mL of Restore™ Western Blot Stripping Buffer (Thermo Fisher) with occasional agitation. Stripped blots were then re-probed, after extensive TBST washing and subsequent blocking, using the methods described above. TIFF image files of probed blots were loaded into Image Labs v6.1.0 (Bio-Rad) for densitometric analysis. Every sample’s intensities were normalized to TBP to retrieve adjusted intensities. Molecular weight analysis was also implemented to identify target bands for statistical analysis.

Quantification and statistical analysis

For analyses comparing multiple groups (single mono-energetic ion studies), Nonparametric one-way ANOVA (Kruskal-Wallis Test) followed by Dunnett’s multiple comparisons test was performed. For studies comparing GCR5-ion to unirradiated controls, nonparametric Mann-Whitney test, two sided was used. For survival curve analyses among multiple groups, Log-rank (Mantel-Cox) test was performed. Western blot densitometric analysis comparing GCR5-ion to unirradiated controls used two-sided unpaired t-tests. GraphPad Prism version 8.0 was used for making data visualization and for statistical analysis. Significance was considered at p ≤ 0.05.
REAGENT or RESOURCESOURCEIDENTIFIER
Antibodies

Rabbit Anti-Fibulin 5 pAbThermo FisherCAT#12188-1-AP; RRID: AB_2105939
Rabbit Anti-TGF-β1 mAbAbcamProduct code ab215715; RRID: AB_2893156
Rabbit Anti-eGFR mAbAbcamProduct code ab52894; RRID: AB_869579
Goat Anti-Rabbit IgG (H + L)-HRP ConjugateBio-RadCAT# 1706515; RRID: AB_11125142
Rabbit Anti-Fibulin 4 pAbThermo FisherCAT# BS-13059R

Biological samples

Mouse: C57BL/6J male heart tissueBowles Lab (Duke University); this studyN/A

Critical commercial assays

4–20% Mini-PROTEAN® TGX Stain-Free™ Protein Gels, 15 well, 15 μlBio-RadCat# 4568096
Clarity Max Western ECL Substrate, 100 mlBio-RadCAT# 1705062
Restore™ Western Blot Stripping BufferThermo FisherCAT# 21059

Experimental models: Organisms/strains

Mouse: C57BL/6J maleJackson LaboratoriesStrain # 000664; RRID:IMSR_JAX:000664

Software and algorithms

Vevo Lab v5.2.6FujiFilm Visualsonicshttps://www.visualsonics.com/product/software/vevo-lab
PVANMillar Instrumentshttps://www.adinstruments.com/support/downloads/windows/pvan
ParaVision v6.01Bruker Inc.https://www.bruker.com/en/products-and-solutions/preclinical-imaging/paravision-360.html
3D SlicerN/Awww.slicer.org
GraphPad Prism v8.0GraphPad Softwarehttps://www.graphpad.com/scientific-software/prism/
Image Lab v6.1.0Bio-Radhttps://www.bio-rad.com/en-us/product/image-lab-software?ID=KRE6P5E8Z

Other

Galactic Cosmic Rays (GCR)Brookhaven National LaboratoryN/A
J. L. Shepherd Mark I Model 68A 137Cs Gamma IrradiatorJ. L. Shepherd & AssociatesN/A
Histology ServicesDuke Pathology Research Immunohistology LabN/A
  31 in total

1.  Summary of final report: Space Life Sciences Planning Workshop (SLSPW). June 5-7, 2000 Mont Tremblant, Quebec.

Authors:  J R Ledsome
Journal:  Can J Physiol Pharmacol       Date:  2001-09       Impact factor: 2.273

2.  Different Sequences of Fractionated Low-Dose Proton and Single Iron-Radiation-Induced Divergent Biological Responses in the Heart.

Authors:  Sharath P Sasi; Xinhua Yan; Marian Zuriaga-Herrero; Hannah Gee; Juyong Lee; Raman Mehrzad; Jin Song; Jillian Onufrak; James Morgan; Heiko Enderling; Kenneth Walsh; Raj Kishore; David A Goukassian
Journal:  Radiat Res       Date:  2017-06-14       Impact factor: 2.841

3.  The two-pore domain potassium channel TREK-1 mediates cardiac fibrosis and diastolic dysfunction.

Authors:  Dennis M Abraham; Teresa E Lee; Lewis J Watson; Lan Mao; Gurangad Chandok; Hong-Gang Wang; Stephan Frangakis; Geoffrey S Pitt; Svati H Shah; Matthew J Wolf; Howard A Rockman
Journal:  J Clin Invest       Date:  2018-10-02       Impact factor: 14.808

4.  Galactic cosmic ray simulation at the NASA Space Radiation Laboratory.

Authors:  John W Norbury; Walter Schimmerling; Tony C Slaba; Edouard I Azzam; Francis F Badavi; Giorgio Baiocco; Eric Benton; Veronica Bindi; Eleanor A Blakely; Steve R Blattnig; David A Boothman; Thomas B Borak; Richard A Britten; Stan Curtis; Michael Dingfelder; Marco Durante; William S Dynan; Amelia J Eisch; S Robin Elgart; Dudley T Goodhead; Peter M Guida; Lawrence H Heilbronn; Christine E Hellweg; Janice L Huff; Amy Kronenberg; Chiara La Tessa; Derek I Lowenstein; Jack Miller; Takashi Morita; Livio Narici; Gregory A Nelson; Ryan B Norman; Andrea Ottolenghi; Zarana S Patel; Guenther Reitz; Adam Rusek; Ann-Sofie Schreurs; Lisa A Scott-Carnell; Edward Semones; Jerry W Shay; Vyacheslav A Shurshakov; Lembit Sihver; Lisa C Simonsen; Michael D Story; Mitchell S Turker; Yukio Uchihori; Jacqueline Williams; Cary J Zeitlin
Journal:  Life Sci Space Res (Amst)       Date:  2016-02-17

Review 5.  Elastic properties and Windkessel function of the human aorta.

Authors:  G G Belz
Journal:  Cardiovasc Drugs Ther       Date:  1995-02       Impact factor: 3.727

Review 6.  Molecular mechanisms and cardiovascular implications of cancer therapy-induced senescence.

Authors:  Ibrahim Y Abdelgawad; Karim T Sadak; Diana W Lone; Mohamed S Dabour; Laura J Niedernhofer; Beshay N Zordoky
Journal:  Pharmacol Ther       Date:  2020-12-01       Impact factor: 12.310

7.  What happens to your brain on the way to Mars.

Authors:  Vipan K Parihar; Barrett Allen; Katherine K Tran; Trisha G Macaraeg; Esther M Chu; Stephanie F Kwok; Nicole N Chmielewski; Brianna M Craver; Janet E Baulch; Munjal M Acharya; Francis A Cucinotta; Charles L Limoli
Journal:  Sci Adv       Date:  2015-05-01       Impact factor: 14.136

8.  Radiation Exposure and Mortality from Cardiovascular Disease and Cancer in Early NASA Astronauts.

Authors:  S Robin Elgart; Mark P Little; Lori J Chappell; Caitlin M Milder; Mark R Shavers; Janice L Huff; Zarana S Patel
Journal:  Sci Rep       Date:  2018-05-31       Impact factor: 4.379

9.  NASA's first ground-based Galactic Cosmic Ray Simulator: Enabling a new era in space radiobiology research.

Authors:  Lisa C Simonsen; Tony C Slaba; Peter Guida; Adam Rusek
Journal:  PLoS Biol       Date:  2020-05-19       Impact factor: 8.029

10.  Apollo Lunar Astronauts Show Higher Cardiovascular Disease Mortality: Possible Deep Space Radiation Effects on the Vascular Endothelium.

Authors:  Michael D Delp; Jacqueline M Charvat; Charles L Limoli; Ruth K Globus; Payal Ghosh
Journal:  Sci Rep       Date:  2016-07-28       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.