Literature DB >> 35371965

Relationship of body mass index and abdominal fat with radiation dose received during preoperative liver CT in potential living liver donors: a cross-sectional study.

Sunyoung Lee1, Kyoung Won Kim2, Heon-Ju Kwon3, Jeongjin Lee4, Kyoyeong Koo4, Gi-Won Song5, Sung-Gyu Lee5.   

Abstract

Background: Although contrast-enhanced computed tomography (CT) is currently the most widely-used imaging modality for the preoperative evaluation of potential living liver donors, radiation exposure remains a major concern. The present study aimed to determine the relationship of body mass index (BMI) and abdominal fat with the effective radiation dose received during liver CT scans as part of a pre-donation work-up in potential living donors.
Methods: This retrospective cross-sectional study included 695 potential living donors (mean age, 30.5±9.7 years; 445 men and 250 women) who had undergone preoperative liver CT scans between 2017 and 2018. The following measures were evaluated: BMI, abdominal fat as measured at the level of the third lumbar vertebra, and effective dose based on the dose length product (DLP). Correlations between the effective dose and other variables were evaluated using Pearson's correlation coefficient.
Results: The mean BMI, total fat area (TFA), and effective dose were 23.6±3.3 kg/m2, 218.7±110.0 cm2, and 9.4±3.3 mSv, respectively. The effective dose during liver CT scans had a strong positive correlation with both BMI (r=0.715; P<0.001) and TFA (r=0.792; P<0.001). As BMI and TFA increased, so did the effective dose. Conclusions: Higher BMI and TFA significantly increased the radiation dose received during liver CT scans in potential living donors. 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Computed tomography (CT); liver transplantation (LT); living donors; radiation dose

Year:  2022        PMID: 35371965      PMCID: PMC8923845          DOI: 10.21037/qims-21-977

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  23 in total

1.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

2.  "All-in-one" imaging protocols for the evaluation of potential living liver donors: comparison of magnetic resonance imaging and multidetector computed tomography.

Authors:  Tobias Schroeder; Massimo Malagó; Jörg F Debatin; Mathias Goyen; Silvio Nadalin; Stefan G Ruehm
Journal:  Liver Transpl       Date:  2005-07       Impact factor: 5.799

3.  Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control.

Authors:  Gary M Israel; Lawrence Cicchiello; James Brink; Walter Huda
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

4.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

5.  Comparison of multidetector computed tomography angiography and cholangiography performed at 80 and 120 kVp in live liver donors.

Authors:  Steffen Huber; Daniel Cornfeld; Sukru H Emre; Gary M Israel
Journal:  J Comput Assist Tomogr       Date:  2013 May-Jun       Impact factor: 1.826

6.  Reproducibility and reliability of computed tomography volumetry in estimation of the right-lobe graft weight in adult-to-adult living donor liver transplantation: Cantlie's line vs portal vein territorialization.

Authors:  Heon-Ju Kwon; Kyoung Won Kim; Jin Kyoo Jang; Jeongjin Lee; Gi-Won Song; Sung-Gyu Lee
Journal:  J Hepatobiliary Pancreat Sci       Date:  2020-05-19       Impact factor: 7.027

7.  The relationship of body mass index and abdominal fat on the radiation dose received during routine computed tomographic imaging of the abdomen and pelvis.

Authors:  Victoria O Chan; Shaunagh McDermott; Orla Buckley; Sonya Allen; Michael Casey; Risteard O'Laoide; William C Torreggiani
Journal:  Can Assoc Radiol J       Date:  2011-12-03       Impact factor: 2.248

8.  Patient-Informed Organ Dose Estimation in Clinical CT: Implementation and Effective Dose Assessment in 1048 Clinical Patients.

Authors:  Wanyi Fu; Francesco Ria; William Paul Segars; Kingshuk Roy Choudhury; Joshua M Wilson; Anuj J Kapadia; Ehsan Samei
Journal:  AJR Am J Roentgenol       Date:  2021-01-21       Impact factor: 3.959

9.  Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study.

Authors:  Sebastian T Schindera; Rendon C Nelson; Thomas L Toth; Giao T Nguyen; Greta I Toncheva; David M DeLong; Terry T Yoshizumi
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

10.  Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians.

Authors:  John D Mathews; Anna V Forsythe; Zoe Brady; Martin W Butler; Stacy K Goergen; Graham B Byrnes; Graham G Giles; Anthony B Wallace; Philip R Anderson; Tenniel A Guiver; Paul McGale; Timothy M Cain; James G Dowty; Adrian C Bickerstaffe; Sarah C Darby
Journal:  BMJ       Date:  2013-05-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.