Seyedeh Sareh Hendi1, Erfan Ahmadyani1, Mohammad Yousef Alikhani2, Maryam Farhadian3, Alireza Mirzaei4.
Abstract
The aim of this study was to investigate the antibacterial effects of 445 nm blue diode lasers and erbium chromium lasers on the biofilm of Enterococcus faecalis in root canal dentin with different thicknesses. Dentin slices with thicknesses of 300, 500, and 1,000 microns were prepared; and after the biofilm formation, they were randomly divided into four groups: group A : Er, Cr:YSGG laser radiation; group B: 445 nm diode laser radiation; group C : laser radiation in three cycles; and control group D: 5 samples of each thickness were selected as a positive control group. Er, Cr:YSGG and diode lasers alone did not significantly reduce the number of bacteria in any of the thicknesses. Only in 1 mm thick sections, the group exposed with the both Er, Cr:YSGG laser and 445 nm diode laser (66%) significantly reduced the number of bacteria. There was a significant difference in a thickness of 0.3 mm compared to a thickness of 1 mm, indicating that these lasers had a better effect at a thickness of 0.3 mm than at 1 mm parts (P-value < 0.008). It seems that these lasers can be used as an adjunct to conventional chemical methods in cleaning infected canals.Entities:
Year: 2022 PMID: 35368314 PMCID: PMC8975713 DOI: 10.1155/2022/6119464
Source DB: PubMed Journal: Int J Dent ISSN: 1687-8728
Figure 1Flowchart for design study.
Comparison of the number of bacteria in different groups with the same thickness.
| Thickness (mm) | Group | Mean | S.D | Average bacterial reduction (%) |
|
|---|---|---|---|---|---|
| 0.3 | Er, Cr:YSGG laser | 216900.00 | 103530.40 | 44 | 0.285 |
| 445 nm diode laser | 205000.00 | 208595.90 | 48 | ||
| Er, Cr:YSGG +445 nm diode laser | 158111.11 | 135794.37 | 60 | ||
| Control | 390000.00 | 176776.69 | |||
|
| |||||
| 0.5 | Er, Cr:YSGG laser | 463500.00 | 4513383.07 | 28 | 0.096 |
| 445 nm diode laser | 514100.00 | 347925.10 | 20 | ||
| Er, Cr:YSGG +445 nm diode laser | 245800.00 | 189973.56 | 62 | ||
| Control | 637000.00 | 331911.13 | |||
|
| |||||
| 1.0 | Er, Cr:YSGG laser | 457600.00 | 224649.94 | 34 | <0.001 |
| 445 nm diode laser | 969000.00 | 623270.05 | 0 | ||
| Er, Cr:YSGG +445 nm diode laser | 237300.00 | 158675.10 | 66 | ||
| Control | 691142.85 | 139632.16 | |||
Kruskal-Wallis test.
Figure 2Bacterial culturing before and after irradiation. (a) Er, Cr:YSGG laser, (a) 0.3 mm thickness; (b) 0.5 mm thickness; and (c) 1 mm thickness. (b) 445 nm diode laser: (a) 0.3 mm thickness; (b) 0.5 mm thickness; and (c) 1 mm thickness. (c) Er, Cr:YSGG and 445 nm diode lasers, (a) 0.3 mm thickness; (b) 0.5 mm thickness; and (c) 1 mm thickness.
Comparison of the number of bacteria in different groups with a thickness of 1 m.
| Thickness (mm) | Group |
|
|---|---|---|
| 1 | Er, Cr:YSGG laser compared to 445 nm diode laser | 0.038 |
| Er, Cr:YSGG laser compared to both erbium and 445 nm diode lasers | 0.021 | |
| Er, Cr:YSGG laser compared to control group | 0.025 | |
| 445 nm diode laser compared to both Er, Cr:YSGG and 445 nm diode lasers | 0.001 | |
| 445 nm diode laser compared to control group | 0.558 | |
| Both Er, Cr:YSGG and 445 nm diode lasers compared to the control group | 0.001 |
Mann-Whitney test with Bonferroni correction.
Comparison of the number of bacteria in different thicknesses for each group.
| Group | Thickness |
|
|---|---|---|
| Er, Cr:YSGG laser | 0.3 | 0.019 |
| 0.5 | ||
| 1.0 | ||
| 445 nm diode laser | 0.3 | 0.004 |
| 0.5 | ||
| 1.0 | ||
| Er, Cr:YSGG laser +445 nm diode laser | 0.3 | 0.531 |
| 0.5 | ||
| 1.0 | ||
| Control | 0.3 | 0.212 |
| 0.5 | ||
| 1.0 |
Kruskal-Wallis test with a significance level of less than 0.05.
Two-by-two examination of thicknesses in two groups of Er, Cr:YSGG laser and 445 nm diode laser.
| Group | Thickness (mm) |
|
|---|---|---|
| 0.3 vs 0.5 | 0.069 | |
| Er, Cr:YSGG laser | 1 vs 0.3 | 0.005 |
| 1 vs 0.5 | 0.45 | |
| 0.5 vs 0.3 | 0.086 | |
| 445 nm diode laser | 1 vs 0.3 | 0.002 |
| 1 vs 0.5 | 0.070 |
∗Mann-Whitney test.
Figure 3Pair comparison of thickness in two groups of Er, Cr:YSGG and 445 nm diode lasers.