Circular-ranging optical coherence tomography (CR-OCT) systems that use a time-stepped frequency comb source generate interference fringe signals that are more complex than those of a conventional swept-source OCT system. Here, we define a common terminology for describing these signals, and we develop a mathematical framework that relates the radio-frequency (RF) properties of these fringe signals to the parameters of the frequency comb source. With this framework, we highlight non-intuitive mechanisms whereby the design of the frequency comb source can affect imaging performance. We show, for example, that amplitude-pulsed time-stepped frequency comb sources have a sensitivity advantage over constant power time-stepped frequency comb sources. More broadly, this framework and associated terminology provide a foundation on which to design and optimize time-stepped frequency comb sources and systems.

Entities:  

Mesh:

Year:  2022        PMID: 35363765      PMCID: PMC9027934          DOI: 10.1364/OL.450318

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.560


  11 in total

1.  High-speed optical frequency-domain imaging.

Authors:  S Yun; G Tearney; Johannes de Boer; N Iftimia; B Bouma
Journal:  Opt Express       Date:  2003-11-03       Impact factor: 3.894

2.  Stable multi-megahertz circular-ranging optical coherence tomography at 1.3 µm.

Authors:  Norman Lippok; Brett E Bouma; Benjamin J Vakoc
Journal:  Biomed Opt Express       Date:  2019-12-09       Impact factor: 3.732

3.  Frequency comb swept lasers.

Authors:  Tsung-Han Tsai; Chao Zhou; Desmond C Adler; James G Fujimoto
Journal:  Opt Express       Date:  2009-11-09       Impact factor: 3.894

4.  Extended Coherence Length and Depth Ranging Using a Fourier-Domain Mode-Locked Frequency Comb and Circular Interferometric Ranging.

Authors:  Norman Lippok; Meena Siddiqui; Benjamin J Vakoc; Brett E Bouma
Journal:  Phys Rev Appl       Date:  2019-01-09       Impact factor: 4.985

5.  Resolving absolute depth in circular-ranging optical coherence tomography by using a degenerate frequency comb.

Authors:  Norman Lippok; Benjamin J Vakoc
Journal:  Opt Lett       Date:  2020-01-15       Impact factor: 3.776

6.  Optical-domain subsampling for data efficient depth ranging in Fourier-domain optical coherence tomography.

Authors:  Meena Siddiqui; Benjamin J Vakoc
Journal:  Opt Express       Date:  2012-07-30       Impact factor: 3.894

7.  High-speed optical coherence tomography by circular interferometric ranging.

Authors:  Meena Siddiqui; Ahhyun S Nam; Serhat Tozburun; Norman Lippok; Cedric Blatter; Benjamin J Vakoc
Journal:  Nat Photonics       Date:  2018-01-29       Impact factor: 38.771

8.  Soliton microcomb based spectral domain optical coherence tomography.

Authors:  Paul J Marchand; Johann Riemensberger; J Connor Skehan; Jia-Jung Ho; Martin H P Pfeiffer; Junqiu Liu; Christoph Hauger; Theo Lasser; Tobias J Kippenberg
Journal:  Nat Commun       Date:  2021-01-18       Impact factor: 14.919

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.