Literature DB >> 35342513

Short-Term Outcomes of Robotic Lateral Unicompartmental Knee Arthroplasty: An Indian Perspective.

Thadi Mohan1, Johncy Panicker1, Jai Thilak1, Druvan Shaji1, Harsha Hari2.   

Abstract

Background: Lateral UKA is a technically more challenging procedure than medial UKA accounting for < 1% of all knee arthroplasties. Robotic UKA for lateral compartment arthritis is rare and has not been reported in India. Materials and
Methods: This is a prospective single-centre clinical study of six patients (five females and one male) who underwent robotic-arm-assisted lateral UKA (RALUKA) between May 2018 and January 2020 with patient-specific 3D-CT preoperative plan. Overall satisfaction on a five-level Likert scale, clinical outcome based on the KOOS and MFJS and radiological outcomes based on the HKA axis, femorotibial angle (FTA), tibial posterior slope (PS) obtained were compared preoperatively and postoperatively.
Results: At a mean follow-up period of 23.84 months, among six patients 33.3% very satisfied, 50% satisfied and 16.7% felt neutral. The mean KOOS changed from 63.03 ± 3.52 to 93.95 ± 3.25 and the mean MFJS was 75.41 ± 10.29 postoperatively. The mean HKA axis changed from 175.81° ± 2.88 valgus to 179.99° ± 2.14 neutral alignment. The mean correction attained was from 4.19° ± 2.88 valgus deformity to 0.01° ± 2.14. The mean FTA and the mean PS changed from 7.34° ± 4.14 of valgus to 1.92° ± 1.85 of valgus and 83.44° ± 1.77 to 85.38° ± 2.10, respectively. Conclusions: The mean preoperative and postoperative KOOS showed a statistical significance with a p value of < 0.001 (< 0.05), showing significant improvement with RALUKA. RALUKA is a promising surgical option for lateral compartment OA of the knee. © Indian Orthopaedics Association 2021.

Entities:  

Keywords:  Arthroplasty; Knee osteoarthritis; Lateral unicompartment osteoarthritis; Robotic surgery; Robotic-arm-assisted surgery; UKA

Year:  2021        PMID: 35342513      PMCID: PMC8921465          DOI: 10.1007/s43465-021-00555-7

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


  23 in total

1.  Unicompartmental knee arthroplasty for lateral gonarthrosis: midterm results.

Authors:  T Ohdera; J Tokunaga; A Kobayashi
Journal:  J Arthroplasty       Date:  2001-02       Impact factor: 4.757

Review 2.  Unicondylar knee arthroplasty.

Authors:  S C Kozinn; R Scott
Journal:  J Bone Joint Surg Am       Date:  1989-01       Impact factor: 5.284

Review 3.  Lateral unicompartmental replacement: a road less traveled.

Authors:  Richard D Scott
Journal:  Orthopedics       Date:  2005-09       Impact factor: 1.390

Review 4.  Unicompartmental knee arthroplasty.

Authors:  Todd Borus; Thomas Thornhill
Journal:  J Am Acad Orthop Surg       Date:  2008-01       Impact factor: 3.020

5.  Robotic arm-assisted unicompartmental knee arthroplasty: preoperative planning and surgical technique.

Authors:  Martin Roche; Padhraig F O'Loughlin; Daniel Kendoff; Volker Musahl; Andrew D Pearle
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2009-02

6.  Robotic arm-assisted UKA improves tibial component alignment: a pilot study.

Authors:  Jess H Lonner; Thomas K John; Michael A Conditt
Journal:  Clin Orthop Relat Res       Date:  2009-07-11       Impact factor: 4.176

7.  Lateral compartment arthroplasty of the knee.

Authors:  L Marmor
Journal:  Clin Orthop Relat Res       Date:  1984-06       Impact factor: 4.176

8.  An assessment of early functional rehabilitation and hospital discharge in conventional versus robotic-arm assisted unicompartmental knee arthroplasty: a prospective cohort study.

Authors:  B Kayani; S Konan; J Tahmassebi; F E Rowan; F S Haddad
Journal:  Bone Joint J       Date:  2019-01       Impact factor: 5.082

Review 9.  The role of unicompartmental knee arthroplasty versus total knee arthroplasty in providing maximal performance and satisfaction.

Authors:  Craig M McAllister
Journal:  J Knee Surg       Date:  2008-10       Impact factor: 2.757

10.  Accuracy of tibial component positioning in the robotic arm assisted versus conventional unicompartmental knee arthroplasty.

Authors:  Jai Thilak; Mohan Thadi; Prajwal P Mane; Anubhav Sharma; Vipin Mohan; Balu C Babu
Journal:  J Orthop       Date:  2020-08-31