Literature DB >> 3531480

A survey of crown and fixed partial denture failures: length of service and reasons for replacement.

J N Walton, F M Gardner, J R Agar.   

Abstract

The mean length of service of all restorations observed in this study was 8.3 years. Caries was the most common cause of failure, affecting 22.0% of the units failed and leading to the necessity for replacement of 24.3% of the units observed. Mechanical problems accounted for 69.5% of the failed units as opposed to 28.5% for oral disease. Resin veneer metal crowns provided the longest service of all crown types observed (13.9 years) and failed most frequently because of worn or lost veneers. The complete veneer metal crown had a life span of 6.1 years and was most likely to fail because of caries or defective margins. Ceramic-metal crowns also showed a relatively short period of service at 6.5 years, needing replacement primarily because of porcelain failure or poor esthetics. The resin-veneer metal crown also provided the longest service as a retainer, with a mean length of service of 14.7 years. This was closely followed by the partial veneer retainer (14.3 years), while the ceramic-metal retainer had the shortest life span (6.3 years). No apparent relationship was found between the span of prosthesis and its length of service. The six-unit canine-to-canine fixed partial denture exhibited the greatest longevity of the prostheses studied (10.4 years), while the two-unit cantilever fixed partial denture provided a mean of only 3.7 years of service before replacement was required.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3531480     DOI: 10.1016/0022-3913(86)90379-3

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  26 in total

1.  Contact damage in model dental multilayers: an investigation of the influence of indenter size.

Authors:  P Shrotriya; R Wang; N Katsube; R Seghi; W O Soboyejo
Journal:  J Mater Sci Mater Med       Date:  2003-01       Impact factor: 3.896

2.  In vitro Evaluation of the Accuracy of Seating Cast Metal Fixed Partial Denture on the Abutment Teeth with Varying Degree of Convergence Angle.

Authors:  Swati S Kharat; Aravind Tatikonda; Seema Raina; Priyanka Gubrellay; Naveen Gupta; Swati Joshi Asopa
Journal:  J Clin Diagn Res       Date:  2015-07-01

3.  Conventional and contemporary luting cements: an overview.

Authors:  Komal Ladha; Mahesh Verma
Journal:  J Indian Prosthodont Soc       Date:  2010-12-12

4.  Effect of four surface treatment methods on the shear bond strength of resin cement to zirconia ceramics- a comparative in vitro study.

Authors:  Varsha Murthy; David Livingstone
Journal:  J Clin Diagn Res       Date:  2014-09-20

5.  Cyclic contact fatigue behavior of baria-silicate glass-ceramics as a function of crystal aspect ratio.

Authors:  K Suputtamongkol; K J Anusavice; J J Mecholsky
Journal:  J Eur Ceram Soc       Date:  2022-01-11       Impact factor: 6.364

6.  Success of fixed partial denture prostheses observed in a military dental centre: A cross-sectional study.

Authors:  A Datta; H S Sandhu
Journal:  Med J Armed Forces India       Date:  2020-11-03

7.  Priming the tooth surface with chlorhexidine and antibacterial activity of resin cement.

Authors:  Monika Saini; Yashpal Singh; Rishabh Garg; Anita Pandey
Journal:  World J Clin Cases       Date:  2013-11-16       Impact factor: 1.337

8.  Effect of Abutment Height on Retention of Single Cement-retained, Wide- and Narrow-platform Implant-supported Restorations.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Sara Nuroloyuni; Sohleh Khodabakhsh; Mehran Bahrami; Reza Nahidi; Somaieh Zeighami
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2012-09-01

9.  Effect of axial groove and resin luting cements on the retention of complete cast metal crowns.

Authors:  K Rajkumar; Aruna M Bhat; Prasad D Krishna; Chetan Hegde; Manoj Shetty; N Sridhar Shetty
Journal:  Dent Res J (Isfahan)       Date:  2009

10.  Relevance of variations in the opposing dentition for the functionality of fixed and removable partial dentures: a systematic review.

Authors:  Bernhard Pommer; Martin Krainhöfner; Georg Watzek; Gabor Tepper; Charalabos-Markos Dintsios
Journal:  Int J Dent       Date:  2012-11-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.