Literature DB >> 3530625

Improvement of positive blood culture detection by agitation.

B L Hawkins, E M Peterson, L M de la Maza.   

Abstract

To evaluate the advantages of agitation in reducing the detection time and increasing the recovery rate of positive blood cultures, 1,000 three-bottle sets of tryptic soy broth on adult inpatients were analyzed. Two bottles were transiently vented, one of which was agitated (250 rpm) for 7-19 hr at 35 degrees C. The other vented bottle and the anaerobic bottle were incubated stationary at 35 degrees C. Smears and subcultures were performed 7-19 hr after collection on both agitated and nonagitated vented bottles. Subcultures were done on all bottles at 72 hr and smears were performed on the anaerobic bottle. There were 137 of 1000 (13.7%) positive cultures from 90 patients. The agitated bottle detected 112 of 137 (81.8%) positive cultures, was the first or only means of detection in 57 of 137 cultures (41.6%), and was the only positive bottle in 30 of 137 (21.9%) cultures. The nonagitated vented bottle detected 89 of 137 (65.0%) of positive cultures and was the only means of detection in 13 of 137 (9.5%), but was never the first means of detection. The anaerobic bottle detected 76 of 137 (55.5%) of positive cultures, was the first or only means of detection in 11 of 137 (8.0%), and was the first means of detection in one of 137 (0.7%) cultures. When both the agitated and nonagitated bottle were positive, the agitated bottle was positive on the average 35 hr earlier. We conclude that agitation of the vented bottle in a conventional blood culture system significantly decreases the detection time of positive blood cultures and increases the number of positive blood cultures detected.

Entities:  

Mesh:

Year:  1986        PMID: 3530625     DOI: 10.1016/0732-8893(86)90003-9

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  9 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

Review 2.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

3.  Clinical comparison of the recoveries of bloodstream pathogens in Septi-Chek brain heart infusion broth with saponin, Septi-Chek tryptic soy broth, and the isolator lysis-centrifugation system.

Authors:  P R Murray; A W Spizzo; A C Niles
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

4.  Comparative evaluation of the oxoid signal and Roche Septi-Chek blood culture systems.

Authors:  P R Murray; A C Niles; R L Heeren; M M Curren; L E James; J E Hoppe-Bauer
Journal:  J Clin Microbiol       Date:  1988-12       Impact factor: 5.948

5.  Comparison of the BacT/Alert pediatric blood culture system, Pedi-BacT, with conventional culture using the 20-milliliter Becton-Dickinson supplemented peptone broth tube.

Authors:  K K Krisher; D R Whyburn; F E Koepnick
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

6.  Critical assessment of blood culture techniques: analysis of recovery of obligate and facultative anaerobes, strict aerobic bacteria, and fungi in aerobic and anaerobic blood culture bottles.

Authors:  P R Murray; P Traynor; D Hopson
Journal:  J Clin Microbiol       Date:  1992-06       Impact factor: 5.948

7.  Evaluation of two commercial blood culture media for the detection of blood-borne pathogens.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1994-01       Impact factor: 3.267

8.  Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

Authors:  P R Murray
Journal:  J Clin Microbiol       Date:  1991-01       Impact factor: 5.948

9.  Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

Authors:  M P Weinstein; S Mirrett; L G Reimer; L B Reller
Journal:  J Clin Microbiol       Date:  1989-03       Impact factor: 5.948

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.