Literature DB >> 3530190

Acetabular reinforcement in total hip replacement.

G Mayer, K Hartseil.   

Abstract

In 21 cases of severe secondary protrusio acetabuli with extensive or total destruction of the acetabular cortical structures, the double anchorage of conventional polyethylene cups with nine Müller acetabular reinforcement rings and 12 Burch-Schneider anti-protrusio reinforcement cages was carried out. They were applied in combination with reconstructive surgery of cancellous bone in three primary total hip replacements and in 18 revision operations for loosened acetabular cups following total arthroplasties. Indication for and technique of the acetabular reinforcement are described. The radiological and clinical results in 21 patients followed up were satisfactory. They confirm the efficiency of these screw-fixed reinforcement implants for the solid fixation of the plastic cup in patients with extreme acetabular deficiencies.

Entities:  

Mesh:

Year:  1986        PMID: 3530190     DOI: 10.1007/bf00435486

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  16 in total

1.  [Suggestion for surgical treatment of acetabular protrusion].

Authors:  J Eichler
Journal:  Arch Orthop Unfallchir       Date:  1973

2.  The measurement of progression in protrusio acetabuli.

Authors:  M J Hubbard
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1969-07

3.  Incorporation of bone graft covered with methylmethacrylate onto acetabular wall. An experimental study.

Authors:  M Roffman; M Silbermann; D G Mendes
Journal:  Acta Orthop Scand       Date:  1983-08

4.  A preliminary review of the Müller acetabular and Burch-Schneider antiprotrusio support rings.

Authors:  J Schatzker; M K Glynn; D Ritter
Journal:  Arch Orthop Trauma Surg       Date:  1984

5.  [Spongiosaplasty of the acetabular floor in total prosthetic replacement of the protrusion hip].

Authors:  H Bereiter; E Morscher
Journal:  Beitr Orthop Traumatol       Date:  1982-08

6.  Socket fixation using a metal-backed acetabular component for total hip replacement. A minimum five-year follow-up.

Authors:  W H Harris; R E White
Journal:  J Bone Joint Surg Am       Date:  1982-06       Impact factor: 5.284

7.  Bone-grafting in total hip replacement for acetabular protrusion.

Authors:  D E McCollum; J A Nunley; J M Harrelson
Journal:  J Bone Joint Surg Am       Date:  1980-10       Impact factor: 5.284

8.  [Reinforcement of the cup in total hip prosthesis (author's transl)].

Authors:  R Schneider
Journal:  Unfallheilkunde       Date:  1980-10

9.  Acetabular reinforcement in total hip replacement.

Authors:  J Schatzker; D E Hastings; R J McBroom
Journal:  Arch Orthop Trauma Surg       Date:  1979-07-31

10.  The use of wire mesh in total hip replacement surgery.

Authors:  W H Harris; W N Jones
Journal:  Clin Orthop Relat Res       Date:  1975 Jan-Feb       Impact factor: 4.176

View more
  1 in total

1.  [Exchange of acetabular cups with severe bone defects using antiprotrusion cages].

Authors:  Bernd Fink; Alexandra Grossmann; Pavel Sebena
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.