Literature DB >> 35289720

Efficacy of dental evacuation systems for aerosol exposure mitigation in dental clinic settings.

Brie Hawley Blackley1, Kimberly R Anderson1, Fotinos Panagakos2, Tammy Chipps2, M Abbas Virji1.   

Abstract

Dental personnel are ranked among the highest risk occupations for exposure to SARS-CoV-2 due to their close proximity to the patient's mouth and many aerosol generating procedures encountered in dental practice. One method to reduce aerosols in dental settings is the use of intraoral evacuation systems. Intraoral evacuation systems are placed directly into a patient's mouth and maintain a dry field during procedures by capturing liquid and aerosols. Although multiple intraoral dental evacuation systems are commercially available, the efficacy of these systems is not well understood. The objectives of this study were to evaluate the efficacy of four dental evacuation systems at mitigating aerosol exposures during simulated ultrasonic scaling and crown preparation procedures. We conducted real-time respirable (PM4) and thoracic (PM10) aerosol sampling during ultrasonic scaling and crown preparation procedures while using four commercially available evacuation systems: a high-volume evacuator (HVE) and three alternative intraoral systems (A, B, C). Four trials were conducted for each system. Respirable and thoracic mass concentrations were measured during procedures at three locations including (1) near the breathing zone (BZ) of the dentist, (2) edge of the dental operatory room approximately 0.9 m away from the mannequin mouth, and (3) hallway supply cabinet located approximately 1.5 m away from the mannequin mouth. Respirable and thoracic mass concentrations measured during each procedure were compared with background concentrations measured in each respective location. Use of System A or HVE reduced thoracic (System A) and respirable (HVE) mass concentrations near the dentist's BZ to median background concentrations most often during the ultrasonic scaling procedure. During the crown preparation, use of System B or HVE reduced thoracic (System B) and respirable (HVE or System B) near the dentist's BZ to median background concentrations most often. Although some differences in efficacy were noted during each procedure and aerosol size fraction, the difference in median mass concentrations among evacuation systems was minimal, ranging from 0.01 to 1.48 µg/m3 across both procedures and aerosol size fractions.

Entities:  

Keywords:  COVID-19; exposure mitigation; respirable; thoracic

Mesh:

Substances:

Year:  2022        PMID: 35289720      PMCID: PMC9365099          DOI: 10.1080/15459624.2022.2053140

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   3.359


  40 in total

1.  The size and the duration of air-carriage of respiratory droplets and droplet-nuclei.

Authors:  J P Duguid
Journal:  J Hyg (Lond)       Date:  1946-09

2.  Exhaled droplets due to talking and coughing.

Authors:  Xiaojian Xie; Yuguo Li; Hequan Sun; Li Liu
Journal:  J R Soc Interface       Date:  2009-10-07       Impact factor: 4.118

3.  Pneumoconiosis and respiratory problems in dental laboratory technicians: analysis of 893 dental technicians.

Authors:  Dilek Ergün; Recai Ergün; Cengiz Ozdemir; Türkan Nadir Oziş; Hinç Yilmaz; Ibrahim Akkurt
Journal:  Int J Occup Med Environ Health       Date:  2014-09-12       Impact factor: 1.843

4.  Characterizing exhaled airflow from breathing and talking.

Authors:  Jitendra K Gupta; Chao-Hsin Lin; Qingyan Chen
Journal:  Indoor Air       Date:  2009-09-11       Impact factor: 5.770

5.  Droplet expulsion from the respiratory tract.

Authors:  R G Loudon; R M Roberts
Journal:  Am Rev Respir Dis       Date:  1967-03

6.  Inhaling to mitigate exhaled bioaerosols.

Authors:  David A Edwards; Jonathan C Man; Peter Brand; Jeffrey P Katstra; K Sommerer; Howard A Stone; Edward Nardell; Gerhard Scheuch
Journal:  Proc Natl Acad Sci U S A       Date:  2004-12-06       Impact factor: 11.205

Review 7.  Occupational lung diseases among dental technicians.

Authors:  D Choudat
Journal:  Tuber Lung Dis       Date:  1994-04

8.  Aerosol formation due to a dental procedure: insights leading to the transmission of diseases to the environment.

Authors:  Parisa Mirbod; Eileen A Haffner; Maryam Bagheri; Jonathan E Higham
Journal:  J R Soc Interface       Date:  2021-03-24       Impact factor: 4.118

9.  Aerosol emission and superemission during human speech increase with voice loudness.

Authors:  Sima Asadi; Anthony S Wexler; Christopher D Cappa; Santiago Barreda; Nicole M Bouvier; William D Ristenpart
Journal:  Sci Rep       Date:  2019-02-20       Impact factor: 4.379

10.  SARS-CoV-2: characterisation and mitigation of risks associated with aerosol generating procedures in dental practices.

Authors:  Touraj Ehtezazi; David G Evans; Ian D Jenkinson; Philip A Evans; Vijay J Vadgama; Jaimini Vadgama; Fadi Jarad; Nicholas Grey; Robert P Chilcott
Journal:  Br Dent J       Date:  2021-01-07       Impact factor: 2.727

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.