Literature DB >> 35282671

Safety and effectiveness of introducing a robotic-assisted percutaneous coronary intervention program in a tertiary center: a prospective study.

Pedro A Lemos1, Marcelo Franken1, Jose Mariani1, Adriano Caixeta1, Breno O Almeida1, Fabio G Pitta1, Guy F A Prado1, Stefano Garzon1, Felipe Ramalho1, Gabriel Albuquerque1, Ivanise M Gomes1, Irisvaldo S de Oliveira1, Leonardo Valle1, Leonardo Galastri1, Breno B Affonso1, Felipe Nasser1, Rodrigo G Garcia1.   

Abstract

Background: Robotic-assisted percutaneous coronary intervention (PCI) is a novel technology that permits remote operation of interventional devices. However, little is known about the safety and effectiveness of introducing a robotic PCI program in a hospital already experienced in traditional coronary angioplasty.
Methods: Prospective single-arm survey to assess the safety and effectiveness of robotic-assisted PCI in comparison to pre-defined performance goals. The study cohort comprised all consecutive cases treated with robotic PCI since its introduction. The safety primary endpoint was a composite of (I) overall death or (II) non-fatal adverse events related to target vessel complications (stent thrombosis, myocardial infarction, vessel perforation or cardiac tamponade, or repeat invasive treatment) during the index hospitalization. The efficacy primary endpoint was robotic-assisted procedural success, a composite of (I) successful dilatation of the target lesion and (II) successful robotic assistance, defined as absent non-planned manual conversion.
Results: A total of 83 patients and 112 lesions were prospectively enrolled. The rate of angiographic success was 99.1%. From these, 97 lesions (86.6%) were treated with only robotic PCI or with hybrid according to the pre-interventional plan. The rates of efficacy and safety primary endpoints were 85.7% and 2.4% respectively (P<0.01 for non-inferior to the pre-defined performance threshold). Conclusions: Introduction of robotic-assisted PCI in a tertiary center was associated with safe and effective results, comparable to pre-defined goals of optimal performance. 2022 Cardiovascular Diagnosis and Therapy. All rights reserved.

Entities:  

Keywords:  Coronary; angioplasty; noninferiority; robotics; stent

Year:  2022        PMID: 35282671      PMCID: PMC8898692          DOI: 10.21037/cdt-21-442

Source DB:  PubMed          Journal:  Cardiovasc Diagn Ther        ISSN: 2223-3652


  31 in total

1.  Clinical performance of a novel ultrathin strut, low-dose, sirolimus-eluting stent with abluminal-only biodegradable polymeric coating for patients undergoing percutaneous coronary intervention in the daily practice.

Authors:  Guy F A Prado; Expedito E Ribeiro; Pedro H M C Melo; Fabio A Pinton; Antonio Esteves-Filho; Celso K Takimura; Jose Mariani; Luiz J Kajita; Gilberto Marchiori; Breno de Alencar Araripe Falcao; Micheli Z Galon; Paulo R Soares; Silvio Zalc; Pedro A Lemos
Journal:  Cardiovasc Diagn Ther       Date:  2015-12

2.  The association between experience and proficiency with robotic-enhanced coronary intervention-insights from the PRECISE multi-center study.

Authors:  Giora Weisz; Nathaniel R Smilowitz; D Christopher Metzger; Ronald Caputo; Juan Delgado; J Jeffrey Marshall; George Vetrovec; Mark Reisman; Ron Waksman; Augusto Pichard; Juan F Granada; Jeffrey W Moses; Joseph P Carrozza
Journal:  Acute Card Care       Date:  2014-03-21

3.  Feasibility and Safety of Robotic Peripheral Vascular Interventions: Results of the RAPID Trial.

Authors:  Ehtisham Mahmud; Florian Schmid; Peter Kalmar; Hannes Deutschmann; Franz Hafner; Peter Rief; Marianne Brodmann
Journal:  JACC Cardiovasc Interv       Date:  2016-09-14       Impact factor: 11.195

Review 4.  Recommendations for occupational radiation protection in interventional cardiology.

Authors:  Ariel Durán; Sim Kui Hian; Donald L Miller; John Le Heron; Renato Padovani; Eliseo Vano
Journal:  Catheter Cardiovasc Interv       Date:  2013-03-08       Impact factor: 2.692

5.  An investigation of the radiation dose to staff during cardiac radiological studies.

Authors:  S P Jeans; K Faulkner; H G Love; R A Bardsley
Journal:  Br J Radiol       Date:  1985-05       Impact factor: 3.039

6.  Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions: Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention).

Authors:  Ehtisham Mahmud; Jesse Naghi; Lawrence Ang; Jonathan Harrison; Omid Behnamfar; Ali Pourdjabbar; Ryan Reeves; Mitul Patel
Journal:  JACC Cardiovasc Interv       Date:  2017-07-10       Impact factor: 11.195

7.  Real-life clinical outcomes with everolimus eluting platinum chromium stent with an abluminal biodegradable polymer in patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR).

Authors:  Giovanna Sarno; Bo Lagerqvist; Göran Olivecrona; Christoph Varenhorst; Mikael Danielewicz; Kristina Hambraeus; Daniel Lindholm; Truls Råmunddal; Nils Witt; Stefan James
Journal:  Catheter Cardiovasc Interv       Date:  2017-05-22       Impact factor: 2.692

8.  In-hospital outcomes of delayed stenting in hemodynamically stable patients with ST-segment elevation myocardial infarction: the CCC (Care for Cardiovascular Disease in China) project.

Authors:  Jia-Wei Wu; Hao Hu; Dan Li; Li-Kun Ma
Journal:  Cardiovasc Diagn Ther       Date:  2019-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.