Literature DB >> 28544146

Real-life clinical outcomes with everolimus eluting platinum chromium stent with an abluminal biodegradable polymer in patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR).

Giovanna Sarno1,2, Bo Lagerqvist1,2, Göran Olivecrona3, Christoph Varenhorst1,2, Mikael Danielewicz4, Kristina Hambraeus5, Daniel Lindholm1,2, Truls Råmunddal6, Nils Witt7, Stefan James1,2.   

Abstract

BACKGROUND: No previous studies have evaluated the performance of the Synergy stent in a large real-life population.
OBJECTIVES: To describe the initial real-life experience with a novel everolimus eluting platinum chromium stent with abluminal biodegradable polymer (SYNERGY) in unselected patients from a nationwide registry.
METHODS: All implanted Synergy stents were compared with other new generation drug eluting stents (n-DES) with >1,000 implantations in Sweden between March 2013 and October 2015. Restenosis, definite stent thrombosis (ST), myocardial infarction (MI) and death rates were assessed using propensity score and Cox regression analyses.
RESULTS: A total of 7,886 of Synergy stents and 64,429 other n-DES (BioMatrix, N = 1,953; Orsiro, N = 4,946; Promus Element Plus, N= 2,543; Promus Premier, N= 20,414; Xience Xpedition, N= 7,971, Resolute/Resolute Integrity, N = 19,021; Ultimaster, N = 1,156; Resolute Onyx, N = 6,425) were implanted in 42,357 procedures. Restenosis and stent thrombosis occurred in 642 and 314 cases, respectively, in the overall population at 1 year. The cumulative rate of restenosis (1.1% vs. 1.0%, adjusted HR: 1.24 95% CI: 0.88-1.75; P = 0.21) and ST (0.4% vs. 0.5%, adjusted HR: 0.97; 95% CI: 0.63-1.50; P = 0.17) up to 1 year was low in both the Synergy group and the other n-DES group. Death occurred in 5.2% versus 4.5% (adjusted HR: 1.14; 95% CI: 0.96-1.36; P = 0.11) and MI in 3.2% versus 3.5%, (adjusted HR: 1.11; 95% CI: 0.93-1.33; P = 0.24) up to 1 year.
CONCLUSIONS: In a large real-life population the Synergy stent appears to be safe and effective with a low rate of restenosis and ST comparable with other n-DES.
© 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  drug eluting; percutaneous coronary intervention; restenosis; stent; stent thrombosis

Mesh:

Substances:

Year:  2017        PMID: 28544146     DOI: 10.1002/ccd.27030

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  7 in total

Review 1.  Technological Advances in Stent Therapies: a Year in Review.

Authors:  Jad Raffoul; Ammar Nasir; Andrew J P Klein
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-04-07

2.  Should ultrathin strut drug eluting stents be considered the new benchmark for novel coronary stents approval? The complex interplay between stent strut thickness, polymeric carriers and antiproliferative drugs.

Authors:  Alessandro Lupi; Alon Schaffer; Angelo Sante Bongo
Journal:  J Thorac Dis       Date:  2018-02       Impact factor: 2.895

3.  Safety and effectiveness of introducing a robotic-assisted percutaneous coronary intervention program in a tertiary center: a prospective study.

Authors:  Pedro A Lemos; Marcelo Franken; Jose Mariani; Adriano Caixeta; Breno O Almeida; Fabio G Pitta; Guy F A Prado; Stefano Garzon; Felipe Ramalho; Gabriel Albuquerque; Ivanise M Gomes; Irisvaldo S de Oliveira; Leonardo Valle; Leonardo Galastri; Breno B Affonso; Felipe Nasser; Rodrigo G Garcia
Journal:  Cardiovasc Diagn Ther       Date:  2022-02

Review 4.  Double or Triple Antithrombotic Treatment in Atrial Fibrillation Patients with Acute Myocardial Infarction Undergoing Percutaneous Coronary Intervention.

Authors:  Despoina-Rafailia Benetou; Charalampos Varlamos; Aikaterini Mpahara; Dimitrios Alexopoulos
Journal:  Am J Cardiovasc Drugs       Date:  2021-01       Impact factor: 3.571

5.  XLIMus drug eluting stent: A randomIzed controlled Trial to assess endothelialization. The XLIMIT trial.

Authors:  Luca Testa; Gaetano Pero; Mario Bollati; Matteo Casenghi; Antonio Popolo Rubbio; Magdalena Cuman; Raul Moreno; Antoni Serra; Joan Antoni Gomez; Francesco Bedogni
Journal:  Int J Cardiol Heart Vasc       Date:  2019-04-28

Review 6.  Sirolimus Release from Biodegradable Polymers for Coronary Stent Application: A Review.

Authors:  Wei Xu; Makoto Sasaki; Takuro Niidome
Journal:  Pharmaceutics       Date:  2022-02-24       Impact factor: 6.321

7.  Safety and efficacy of Everolimus-Eluting bioabsorbable Polymer-Coated stent in patients with long coronary lesions: The EVOLVE 48 study.

Authors:  Dimitrios Karmpaliotis; Robert Stoler; Simon Walsh; Seif El-Jack; Srinivasa Potluri; Jeffrey Moses; Keith Oldroyd; Adrian Banning; Mark Webster; Azfar Zaman; Willis Wu; Mudassar Ahmed; Paul Underwood; Dominic Allocco
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-29       Impact factor: 2.585