| Literature DB >> 35279212 |
Mohammed I Amri1, Msaad M Alzhrani2, Ahmad D Alanazi2, Mazen M Alqahtani2, Faizan Zaffar Kashoo3.
Abstract
BACKGROUND: The English version of the Foot Function Index (FFI) is a reliable and valid tool for measuring pain and functional instability due to chronic lateral ankle instability (CLAI). However, its use among Arabic speakers with CLAI is limited because of the unavailability of the Arabic version of the FFI (FFI-Arb). This study aimed to translate, cross-culturally adapt and validate the FFI from the original English version into Arabic.Entities:
Keywords: Chronic lateral ankle instability; Cross cultural adaptation; Foot function index; Foot function index Arabic version; Lateral ankle sprain
Mesh:
Substances:
Year: 2022 PMID: 35279212 PMCID: PMC8917771 DOI: 10.1186/s13047-022-00527-6
Source DB: PubMed Journal: J Foot Ankle Res ISSN: 1757-1146 Impact factor: 2.303
Fig. 1Flow Chart of the sample population, respondents, inclusion, and analysis
Demographic Characteristics of Participants (Age, Weight, Height, injury date) N = 230, N = 92
| Number of participants | ||
|---|---|---|
| Mean ± Std. Deviation | ||
| 179/51 | 67/25 | |
| 32.09 ± 8.642 | 32.99 ± 8.599 | |
| 28.87 ± 22.60 | 32.42 ± 32.79 | |
| 160.91 ± 187.80 | 158 ± 170 | |
Description of the items of FFI-Arb
| FFI-Arb Questionnaire | Mean ± Std. Deviation |
|---|---|
| FFI-1 | 3.52 ± 2.84 |
| FFI-2 | 2.37 ± 2.84 |
| FFI-3 | 2.96 ± 2.89 |
| FFI-4 | 2.59 ± 2.89 |
| FFI-5 | 2.62 ± 2.60 |
| FFI-6 | 2.27 ± 2.58 |
| FF-7 | 0.71 ± 1.74 |
| FF-8 | 0.61 ± 1.57 |
| FF-9 | 3.27 ± 2.79 |
| FF-10 | 1.89 ± 2.46 |
| FF-11 | 2.37 ± 2.69 |
| FF-12 | 2.87 ± 2.92 |
| FF-13 | 2.89 ± 2.93 |
| FF-14 | 2.66 ± 2.81 |
| FF-15 | 3.42 ± 3.15 |
| FF-16 | 1.85 ± 2.48 |
| FF-17 | 2.09 ± 2.54 |
| FF-18 | 3.37 ± 3.15 |
| FFI-19 | 1.98 ± 2.50 |
| FFI-20 | 1.63 ± 2.46 |
| FFI-21 | 2.80 ± 2.67 |
| FFI-22 | 0.52 ± 1.82 |
| FFI-23 | 0.46 ± 1.72 |
Description of the items of the Cumberland Ankle instability tool Arabic version (CAIT-Arab)
| CAIT-Arab | Mean ± Std. Deviation |
|---|---|
| CAIT | 3.47 ± 1.44 |
| CAIT | 2.28 ± 1.42 |
| CAIT | 1.83 ± 1.07 |
| CAIT | 2.27 ± 0.87 |
| CAIT | 1.38 ± 0.70 |
| CAIT | 2.08 ± 1.09 |
| CAIT | 2.82 ± 1.16 |
| CAIT | 1.54 ± 1.09 |
| CAIT | 0.80 ± 1.09 |
Convergent validity (N = 230)
| FFI Questionnaire | CAIT-Arab Total | ||
|---|---|---|---|
| Correlation Coefficient | −.565** | ||
| Sig. (2-tailed) | < 0.001 | ||
| N | 230 | ||
| Correlation Coefficient | −.561** | ||
| Sig. (2-tailed) | < 0.001 | ||
| N | 230 | ||
| Correlation Coefficient | −.512** | ||
| Sig. (2-tailed) | < 0.001 | ||
| N | 230 | ||
| Correlation Coefficient | −.569** | ||
| Sig. (2-tailed) | < 0.001 | ||
| N | 230 | ||
Factor Loading with 3 factors (Rotated Component Matrix)
| Item Number | Questions | Factor structure | ||
|---|---|---|---|---|
| Pain | Disability | Activity limitation | ||
| Item 1 | Worst Leg Pain | .802 | .161 | .130 |
| Item 2 | Morning Leg Pain | .786 | .230 | .142 |
| Item 3 | Walking Leg Pain | .849 | .165 | .095 |
| Item 4 | Standing Leg Pain | .798 | .254 | .055 |
| Item 5 | Walking Shoes Pain | .845 | .285 | .040 |
| Item 6 | Standing Shoes Pain | .789 | .313 | .078 |
| Item 7 | Walking Orthotics Pain | .258 | .861 | .229 |
| Item 8 | Standing Orthotics Pain | .235 | .874 | .257 |
| Item 9 | End Day Leg Pain | .809 | .288 | −.076 |
| Item 10 | Difficulty Walking In House | .829 | .277 | .164 |
| Item 11 | Difficult Walking Outside | .848 | .271 | .100 |
| Item 12 | Difficult Walking 800Meters | .885 | .150 | .184 |
| Item 13 | Difficulty Climbing Stairs | .855 | .135 | .259 |
| Item 14 | Difficulty Descending Stairs | .832 | .175 | .309 |
| Item 15 | Difficulty Standing Tip Toe | .829 | −.030 | .202 |
| Item 16 | Difficulty Getting Up Chair | .791 | .117 | .237 |
| Item 17 | Difficulty Climbing Curbs | .850 | .145 | .249 |
| Item 18 | Difficulty Walking Fast | .857 | .126 | .266 |
| Item 19 | Stay Inside All Day | .767 | .149 | .294 |
| Item 20 | Stay In Bed | .710 | .336 | .336 |
| Item 21 | Limited Activities | .812 | .190 | .201 |
| Item 22 | Use Assistive Device Indoor | .202 | .167 | .881 |
| Item 23 | Use Assistive Device Outdoor | .164 | .259 | .843 |
Extraction Method: Principal Component Analysis
Rotation Method: Varimax with Kaiser Normalization
a. Rotation converged in 5 iterations
Intraclass Correlation Coefficient (ICC) of FFI N = 92
| Item | Average measure | Confidence interval | |
|---|---|---|---|
| 0.996 | 0.994–0.997 | < 0.001 | |
| 0.999 | 0.998–0.999 | < 0.001 | |
| 0.984 | 0.976–0.989 | < 0.001 | |
| 0.998 | 0.997–0.999 | < 0.001 |
Floor and ceiling effect
| FFI-Arb questionnaire | Floor | Ceiling |
|---|---|---|
| < 5.7 | > 0 | |
| < 10.9 | > 0 | |
| < 14.8 | > 0 | |
| < 4.3 | > 0 |