| Literature DB >> 35253872 |
Lucas Van Hoof1, Isabelle Truyers2, Hadewych Van Hauwermeiren2, Bram Nachtergaele2, Tom Langenaeken1, Marc Jacquemin3, Filip Rega1, Peter Verhamme4, Bart Meuris1.
Abstract
OBJECTIVES: The newest mechanical valves have low thrombogenicity, making them candidates for anticoagulation with a direct oral anticoagulant. While these drugs hold great promise to replace warfarin, clinical trials have been disappointing so far. We aimed to evaluate apixaban in a porcine model of mechanical valve thrombosis with On-X® (CryoLife) aortic valves implanted in pulmonary position.Entities:
Keywords: Apixaban; Mechanical valve; On-X; Pig; Thrombosis
Mesh:
Substances:
Year: 2022 PMID: 35253872 PMCID: PMC9297512 DOI: 10.1093/icvts/ivac070
Source DB: PubMed Journal: Interact Cardiovasc Thorac Surg ISSN: 1569-9285
Overview of all animals including weight at operation, apixaban regimen, apixaban peak plasma concentration and thrombus weight on the explanted valve
| Group | Animal nr | Weight | Apixaban regimen | Normalized apixaban dose (mg/kg/d) | Apixaban peak (ng/ml) | Thrombus weight (mg) |
|---|---|---|---|---|---|---|
| Low dose | 1 | 64.3 | 2 × 5 mg 10 weeks | 0.16 | 23.07 | 108.8 |
| 2 | 66.1 | 2 × 5 mg 10 weeks | 0.15 | 64.05 | 548.8 | |
| Intermediary dose | 3 | 52.6 | 2 × 5 mg 6 weeks to 2 × 10 mg 2 weeks | 0.24 | – | 65.5 |
| 4 | 58.9 | 2 × 5 mg 6 weeks to 2 × 10 mg 4 weeks | 0.24 | 39.88 | 41 | |
| 5 | 52.5 | 2 × 5 mg 6 weeks to 2 × 10 mg 4 weeks | 0.27 | 60.99 | 0 | |
| 6 | 54.5 | 2 × 5 mg 6 weeks to 2 × 10 mg 4 weeks | 0.26 | 49.91 | 0 | |
| High dose | 7 | 70.1 | 2 × 15 mg 10 weeks | 0.43 | 44.6 | 0 |
| 8 | 67.6 | 2 × 15 mg 10 weeks | 0.44 | 49.9 | 0 | |
| 9 | 70.9 | 2 × 15 mg 10 weeks | 0.42 | 82.9 | 0 |
Figure 1:Valve macroscopy and thrombus weight on the explanted valves.
Figure 2:Thrombus weight for each valve plotted against the total daily apixaban dosage (mg/day) normalized for preoperative weight (kg). From left to right, 3 clusters are observed corresponding to the low- (n = 2), intermediary- (n = 4) and high-dose (n = 3) groups. Spearmans’s rank correlation coefficient indicates a negative correlation between apixaban dose and thrombus weight [r(7) = −0.82, P = 0.007].