Inflammatory Response to Cobalt-Chromium Alloys Fabricated With Different Techniques.

Maria Kassapidou1,2, Victoria Franke Stenport1, Carina B Johansson1, Anna-Karin Östberg3, Petra Hammarström Johansson1, Lars Hjalmarsson1,4.   

Abstract

OBJECTIVES: To explore the in vitro cytokine expression of human peripheral blood mononuclear cells exposed to cobalt-chromium alloys, manufactured with different techniques, in comparison with commercially pure titanium grade 4 and titanium alloy grade 23.
MATERIAL AND METHODS: Peripheral blood mononuclear cells (PBMC) were collected from 10 healthy blood donors and exposed to machine-ground coin-shaped: (a) cobalt-chromium (Co-Cr) specimens (n = 5) manufactured by four techniques, i.e. cast, milled, laser melted and presintered milled; (b) commercially pure titanium grade 4; and (c) titanium alloy grade 23. The cells were cultured for 4, 24 and 72 hours followed by investigations of pro- and anti-inflammatory cytokine release using Bio-Plex Pro™.
RESULTS: In general, the PBMC produced significantly more cytokines when exposed to the cast and presintered milled Co-Cr materials compared to laser melted, milled Co-Cr and titanium materials.
CONCLUSIONS: Within the limitation of the present study, it may be suggested that cast and presintered milled cobalt-chromium alloys provoke a stronger inflammatory response compared to milled and laser melted cobalt-chromium alloys and titanium materials.
Copyright © Kassapidou M, Stenport VF, Johansson CB, Östberg AK, Hammarström Johansson P, Hjalmarsson L. Published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH (http://www.ejomr.org), 31 December 2021.

Entities:  

Keywords:  cobalt-chromium alloys; cytokine; dental casting technique; inflammation; prosthodontics; titanium

Year:  2021        PMID: 35222870      PMCID: PMC8807148          DOI: 10.5037/jomr.2021.12403

Source DB:  PubMed          Journal:  J Oral Maxillofac Res        ISSN: 2029-283X


INTRODUCTION

Cobalt-chromium (Co-Cr) alloys are being used in the rehabilitation of partially dentate and edentulous patients. In a publication from 2017 it was reported that more than 30 different Co-Cr alloys were used in Sweden for this purpose [1]. Except for variations in composition among the used alloys, they are also manufactured by different techniques, i.e. cast, milled, laser melted and presintered milled [1]. A recent in vitro study investigating the ion release from four different Co-Cr alloys demonstrated a higher ion release from cast and presintered milled Co-Cr as compared to milled and laser melted alloys [2]. Furthermore, a higher cell viability to cast Co-Cr compared to titanium alloy grade 23 (Ti-6Al-4V ELI [extra low interstitial]) was reported [2]. It has been discussed that ion release may initiate an inflammatory response that further activates the host´s immune system [3,4]. The inflammatory response initiates the infiltration of neutrophils and later monocytes and lymphotic cells in the affected area [4]. It has been suggested that an activated inflammatory response may lead to tissue destruction around the implant [5]. In vitro studies have demonstrated that titanium (Ti) ions form particles which have been associated with the stimulation of macrophages that release interleukins (IL)-1β, known for their involvement in bone resorption [6]. In the orthopaedic field, it has been shown that cobalt (Co) ions and particles that are released from orthopaedic implants can be absorbed by macrophages which induce a type IV hypersensitivity reaction [7,8]. Both T-lymphocytes and B-cells (to a lesser extent) are involved in the production of inflammatory mediators, such as cytokines, that regulate the inflammatory phase [9]. Pro- and anti-inflammatory cytokines, i.e. the interleukins IL-1, IL-6, IL-4 and tumour necrosis factor-α (TNF-α), play a central role in the inflammatory reaction [10,11]. The complex interplay between pro- and anti-inflammatory cytokines in an inflammatory process is not fully understood [11]. While the pro-inflammatory cytokines usually act as the dominating mediators for the inflammatory response, the anti-inflammatory cytokines inhibit their release and may cause a weakened inflammatory response [11]. When the phagocytosis of the macrophages fails to eliminate the ions, the macrophages release cytokines, i.e. IL-1, IL-6, TNF-α and prostaglandin [7]. The pro-inflammatory cytokines IL-1 (rα and β) and TNF-α have also been shown to stimulate bone resorption and are generally classified as key pro-inflammatory proteins [7,12,13]. In two other in vitro studies, high levels of proinflammatory cytokine release (IL-1β, IL-6, IL-8 and TNF-α) were demonstrated when human monocyte cell lines (THP-1) were exposed to Co-Cr-Mo particles (derived from orthopaedic implants), as well as cobalt-chromium-molybdenum (Co-Cr-Mo) and Ti ions [14,15]. The surface roughness of Co-Cr and titanium has been shown to influence the ion release and inflammatory response [2,16]. In another in vitro study related to the present topic, it was shown that the rough surface created by anodized and fluorinated oxide with nanotubes of titanium grade 4, demonstrated reduced pro-inflammatory cytokine expression of IL-1 β, IL-6 and TNF-α, compared to the smoother surface of titanium grade 4 [17]. However, in another study no statistically significant differences were reported in cytokine expression (TNF-α and IL-10) when comparing different modified surfaces of commercially pure titanium grade 3 [18]. Metal ions may act as initiators for osteolysis and aseptic loosening of an orthopaedic implant [19,20]. A previous in vitro study simulating the clinical situation of a dental implant connected to a supra-construction made of Co-Cr alloys demonstrated a lower total ion release when commercially pure titanium grade 4 (CpTi4) and Co-Cr were simultaneously present, as compared to Co-Cr solely [2]. Another in vitro study investigating implant supra-constructions concluded that the lower metal ion release from platform-switched supra constructions, compared to platform-matched, resulted in a decreased expression of pro-inflammatory cytokines (IL-6 and IL-8) and a reduced marginal bone loss for the platform-switched compared to platform-matched supra constructions [21-23]. However, the immune response to metal ions is a complex process not fully understood [19]. The aims of the present in vitro study were to examine cytokine release from human peripheral blood mononuclear cells exposed to cast, milled, laser melted, and presintered milled cobalt-chromium used in fixed prosthodontics compared to commercially pure titanium grade 4 and titanium alloy grade 23 with a known surface roughness. The null hypothesis was that there are no differences in cytokine release regardless of material.

MATERIAL AND METHODS

This study involved five Co-Cr alloys manufactured with four different techniques: cast, milled, laser melted, and presintered milled (Table 1) [1]:
Table 1

Technical information of the specimens

Manufacturing technique Tradename Composition (%)
Cast1 Wirobond 280® (W280) Co = 60.2; Cr = 25; Mo = 4.8; W = 6.2; Ga = 2.8; Si < 1; Mn < 1

Cast1 Remanium® Star (Rc) Co = 60.5; Cr = 28; Si = 1.5; W = 9; Mn < 1; N < 1; Nb < 1

Milled2 Remanium® Star MDII (Rm) -

Laser melted3 Remanium® Star CL (Rlm) -

Presintered milled4 Zirkonzahn® Sintermetall (Zz) Co = 62 to 68; Cr = 26 to 30; Mo = 5 to 7; N < 0.5; C < 0.5

Cold drawn CpTi4 C < 0.01; N < 1; O = 0.33; Fe = 0.08; H = 0.01; Ti balance

Drawn, annealed Ti-6Al-4V ELI Al = 5.96 to 6.05; V = 4.11 to 4.02; Fe = 0.14 to 0.17; C = 0.008 to 0.009; N = 0.004 to 0.005; O = 0 to 0.12; H = 0 to 0.0018; Ti balance

1The cast specimens; W280 and Rc were cast by an experienced dental technician at the Dental Laboratory Technology in the Institute of Odontology, University of Gothenburg, Sahlgrenska Academy, Sweden, according to the manufacturer´s recommendation.

2Processed by Kullberg Mikroteknik, Lycke, Sweden.

3Received prepared from the manufacturer.

4Final sintering at Säffle Dental AB, Säffle, Sweden. Processed by Kullberg Mikroteknik, Lycke, Sweden.

ELI = extra-low interstitial.

Cast Wirobond 280® (W280) (BEGO; Bremen, Germany); Cast Remanium® Star (Rc) (Dentaurum GmbH & Co. KG; Ispringen, Germany); Milled Remanium® Star MDII (Rm) (Dentaurum GmbH & Co. KG); Laser melted Remanium® Star CL (Rlm) (Dentaurum GmbH & Co. KG); Presintered milled Zirkonzahn® Sintermetall (Zz) (Zirkonzahn S.R.L.; Gais, South Tyrol, Italy). Technical information of the specimens 1The cast specimens; W280 and Rc were cast by an experienced dental technician at the Dental Laboratory Technology in the Institute of Odontology, University of Gothenburg, Sahlgrenska Academy, Sweden, according to the manufacturer´s recommendation. 2Processed by Kullberg Mikroteknik, Lycke, Sweden. 3Received prepared from the manufacturer. 4Final sintering at Säffle Dental AB, Säffle, Sweden. Processed by Kullberg Mikroteknik, Lycke, Sweden. ELI = extra-low interstitial. The laser melted Co-Cr specimens were received prepared from the manufacturer. The milled Co-Cr and titanium (CpTi4 and Ti-6Al-4V ELI) specimens were processed and finalized at a local milling center. As for the presintered milled Co-Cr specimens, they were received in a presintered “soft” state and the finalizing milling and sintering process was performed at a dental laboratory. Only the cast specimens were prepared “in house” by an experienced dental technician. Commercially pure titanium grade 4 and Ti-6Al-4V ELI were included for comparison (Table 1) [1]. Five disc-shaped specimens, with a diameter of 8 mm and a thickness of 2 mm of each material, were ground on both flat sides with silicon carbide (SiC) grinding paper 320 to 1200 grit size (Struers A/S; Ballerup, Denmark), using wet-grinding equipment (EXAKT Apparatebau GmbH & Co. KG; Norderstedt, Germany). The post-grinding cleaning process included: 10 minutes in an ultrasonic bath at 60 ºC, in mixture of 1% Extran® AP 15 (Merck KGaA; Darmstadt, Germany), and 99 % deionisized ultra-pured water. Rinsing in deionized ultrapure water for 30 seconds. Followed by air drying and packing in a sterile bag (Wipak Oy; Helsinki, Finland). Cell culture Buffy coats were obtained from 10 anonymous healthy, volunteer blood donors at the Sahlgrenska University Hospital in Gothenburg, Sweden, between the 20th of March and the 4th of May, in 2018. Peripheral blood mononuclear cells (PBMCs) were isolated by Ficoll-Paque PLUS (GE Healthcare Bio-Sciences AB; Uppsala, Sweden), washed twice in phosphate-buffered saline (PBS) and resuspended in Dulbecco’s modified Eagle’s medium + GlutaMAX-1™ (Gibco, Life Technologies; Paisley, UK) supplemented with 5% heat inactivated human serum type AB (Sigma-Aldrich; St. Louis, Missouri, USA), penicillin (100 U/mL - Sigma-Aldrich), and streptomycin (100 lg/mL - Sigma-Aldrich). Cells were seeded at 2 x 106 cells per well with or without test material in 24-well plates and cultured at 37 °C in a humidified atmosphere with 5 % CO2. Supernatants were collected after 4, 24, and 72 hours of incubation and kept at minus 80 °C until further use. Cytokine analysis Cytokine concentrations in the culture supernatants were measured by Luminex® xMAP® Technology (Luminex Crop.; Austin, Texas, USA) using the commercially available 21-plex and 27-plex screening panels of the Bio-Plex Pro™ Human Cytokine Assay (Bio-Rad Laboratories Inc.; Hemel Hempstead, UK) according to the instructions from the manufacturer. In brief, samples were thawed and centrifuged at 1000 x g for 10 minutes at 4 °C and added to a 96-well plate (Bio-Rad Laboratories Inc.,) prepared with color-coded magnetic beads conjugated with capture antibodies. After 45 min of incubation, followed by a washing procedure, biotinylated detection antibodies were added and allowed to bind for 30 min. After another washing step, streptavidin-conjugated phycoerythrin was added and, after a final washing procedure, quantitative data were acquired by running the samples through the BioPlex® 200 instrument. All washing procedures were performed using the Bio-Plex Pro™ Wash Station (Bio-Rad Laboratories Inc.) and the program indicated in the assay protocol for each step. Analysis and calculations were made using the BioManager analysis software version 6.0 (Bio-Rad Laboratories Inc.) [12], with MountainsMap Premium 7.4.16 software (Digital Surf; Besancon, France). Surface roughness analysis Three disc-shaped specimens (size and cleaning procedure as described above) from each material were randomly selected and examined regarding surface topography with an optical interferometer (smartWLI-extended - GBS; Ilmenau, Germany). Five randomly selected regions/specimen were measured i.e. in total a mean number of 15 measurements per material. High-pass Gaussian filter 50 × 50 μm was utilized to separate roughness from errors of form and waviness [24]. According to previous recommendations, three surface parameters were calculated [24]: Sa (μm) - the average height deviation of each point compared to the arithmetical mean of the surface. Sds (1/μm2) - the density of the summits, i.e. number of summits per area. Sdr (%) - the developed interfacial area ratio; the percentage of the definition area’s additional surface area contributed to the texture as compared to the planar unit definition area. The surface evaluation was performed with MountainsMap Premium 7.4.16 software. Statistical analysis The statistical analysis for cytokine levels included Friedman’s non-parametric test and Dunn´s multiple correction test for post-hoc testing. The One Way ANOVA test was used for analysing surface properties and the Tukey test was applied for pairwise post-hoc testing [25]. Parametric data were expressed as mean and standard deviation (SD). Data processing was performed using GraphPad Prism version 9.1.0 software (GrapdPad Software Inc.; La Jolla, California, USA) and SPSS version 27 (IBM Corp.; Armonk, New York, USA). The significance value level was set to P < 0.05.

RESULTS

Cytokine analysis The results from the multiplex cytokine release test are visualized in the heat map in Figure 1. In general, four hours of incubation did not reveal any major differences between the materials. However, Zz demonstrated seemingly greater cytokine levels of IL-4 and IL-8 after 4 h.
Figure 1

The columns from the heat map represent the specimen material (and control) and the rows represent the cytokine expression profiles from exposed (and non-exposed) peripheral blood mononuclear cells after three days of incubation.

The colour codes symbolize the mean levels of cytokine release from supernatants obtained from 10 anonymous healthy donors: red = high; black = intermediate; green = low.

Co-Cr = cobalt-chromium; W280 = Wirobond 280®; Rc = Remanium® Star; Rm = Remanium® Star MDII; Rlm = Remanium® Star CL; Zz = Zirkonzahn® Sintermetall; CpTi4 = commercially pure titanium grade 4; Ti-6Al-4V = titanium alloy grade 23.

The columns from the heat map represent the specimen material (and control) and the rows represent the cytokine expression profiles from exposed (and non-exposed) peripheral blood mononuclear cells after three days of incubation. The colour codes symbolize the mean levels of cytokine release from supernatants obtained from 10 anonymous healthy donors: red = high; black = intermediate; green = low. Co-Cr = cobalt-chromium; W280 = Wirobond 280®; Rc = Remanium® Star; Rm = Remanium® Star MDII; Rlm = Remanium® Star CL; Zz = Zirkonzahn® Sintermetall; CpTi4 = commercially pure titanium grade 4; Ti-6Al-4V = titanium alloy grade 23. Overall, the milled, laser melted Co-Cr and both titanium materials (CpTi4 and Ti-6Al-4V ELI) demonstrated lower levels of cytokine release (pro- and anti-inflammatory) compared to cast and presintered milled Co-Cr alloys. The levels of cytokine release for the milled, laser melted Co-Cr and titanium specimens, reached a similar level as the controls (cells without any specimen). After one and three days, the pattern changed and higher cytokine levels were observed for the cast Co-Cr and presintered milled compared to the other Co-Cr materials. Except for IL-1ra and IP-10, lower cytokine level release could be observed from CpTi4 and Ti-6Al-4V ELI after three days compared to the CoCr materials. Thus, after both one and three days, the highest cytokine levels were observed for the cast Co-Cr and presintered milled Co-Cr specimens whereas the other Co-Cr alloys, as well as CpTi4 and Ti-6Al-4V ELI, presented very low levels. The expression of pro-inflammatory cytokine levels from day three was selected for the statistical analysis. At the first registration (4 h), low cytokine levels were detected from all cells that were exposed to the materials tested, except for the expression level of RANTES that was upregulated, P > 0.05 (Figures 1, 2, 3). Low levels were observed for the controls of all materials, except for RANTES and IP-10 where the level decreased (for RANTES) and increased (for IP-10), but the differences were not statistically significant, P > 0.05. Statistically significant higher cytokine levels were observed for the following pro-inflammatory cytokines: IL-1β, IL-6, IL-8, IL-17, IFN-γ, and TNF-α when exposed to the cast specimens compared to milled, laser melted, and both groups of titanium specimens, P < 0.05 (Figure 2). A higher value was also observed for the anti-inflammatory cytokine release of IL-4 when exposed to the cast (W280) as compared to milled and laser melted Co-Cr specimens, P < 0.05. Moreover, a higher expression level of anti-inflammatory cytokines (IL-4, IL-10, IL-12, IL-ra) for both cast Co-Cr specimens, compared to CpTi4, P < 0.05, was shown (Figure 3). Also, increased pro-inflammatory cytokine levels (IL-1β, IL-17, IFN-γ and TNF-α) and anti-inflammatory cytokines (IL-4, IL-12) were shown for the presintered milled Co-Cr specimens compared to the milled and laser melted Co-Cr specimens, P < 0.05. No difference in pro- and anti-inflammatory release was observed between the titanium specimens (CpTi4 and Ti-6Al-4V ELI), P > 0.05.
Figure 2

Pro-inflammatory cytokine production by peripheral blood mononuclear cells exposed to cast (W280, Rc), milled (Rm), laser melted (Rlm), presintered (Zz) Co-Cr and titanium (CpTi4, Ti-6Al-4V) after three days.

W280 = Wirobond 280®; Rc = Remanium® Star; Rm = Remanium® Star MDII; Rlm = Remanium® Star CL; Zz = Zirkonzahn® Sintermetall; CpTi4 = commercially pure titanium grade 4.

Figure 3

Anti-inflammatory cytokine production by peripheral blood mononuclear cells exposed to cast (W280, Rc), milled (Rm), laser melted (Rlm), presintered (Zz) Co-Cr and titanium (CpTi4, Ti-6Al-4V) after three days.

Co-Cr = cobalt-chromium; W280 = Wirobond 280®; Rc = Remanium® Star; Rm = Remanium® Star MDII; Rlm = Remanium® Star CL; Zz = Zirkonzahn® Sintermetall; CpTi4 = commercially pure titanium grade 4; Ti-6Al-4V = titanium alloy grade 23.

Pro-inflammatory cytokine production by peripheral blood mononuclear cells exposed to cast (W280, Rc), milled (Rm), laser melted (Rlm), presintered (Zz) Co-Cr and titanium (CpTi4, Ti-6Al-4V) after three days. W280 = Wirobond 280®; Rc = Remanium® Star; Rm = Remanium® Star MDII; Rlm = Remanium® Star CL; Zz = Zirkonzahn® Sintermetall; CpTi4 = commercially pure titanium grade 4. Anti-inflammatory cytokine production by peripheral blood mononuclear cells exposed to cast (W280, Rc), milled (Rm), laser melted (Rlm), presintered (Zz) Co-Cr and titanium (CpTi4, Ti-6Al-4V) after three days. Co-Cr = cobalt-chromium; W280 = Wirobond 280®; Rc = Remanium® Star; Rm = Remanium® Star MDII; Rlm = Remanium® Star CL; Zz = Zirkonzahn® Sintermetall; CpTi4 = commercially pure titanium grade 4; Ti-6Al-4V = titanium alloy grade 23. Surface roughness analysis The results demonstrated extremely small statistically significant differences in surface roughness among the specimens. Range of difference: Sa = 0.02 to 0.03 μm, Sdr = 0.9 to 1.6 %, Sds = 0.03 to 0.05 1/μm2. Slightly higher Sa and Sdr values for the milled and presintered milled Co-Cr specimens and CpTi4, compared to the cast and laser melted Co-Cr specimens, P < 0.05. Commercially pure titanium grade 4 presented higher Sdr values compared to Ti-6Al-4V ELI, P < 0.05. However, all Co-Cr specimens (except for the presintered) demonstrated higher Sds values compared to Ti-6Al-4V ELI, P < 0.05.

DISCUSSION

In summary, the results from the cytokine release test demonstrated that cast and presintered milled Co-Cr specimens initiated higher cytokine levels compared to milled, laser melted Co-Cr and titanium (CpTi4, Ti-6Al-4V ELI) specimens. As has been previously reported in the literature, the surface roughness may affect the inflammatory response to a material [2,17,26]. To avoid the possible impact of surface parameters in our results, we prepared the surfaces of the specimens according to a standardized protocol. Although the mean range difference in surface roughness was extremely small, a slightly rougher surface (Sa, Sdr) was observed for the milled and presintered Co-Cr specimens compared to cast and laser melted Co-Cr specimens (P < 0.05). In a previous study by our research group, it was demonstrated that cast Co-Cr specimens showed higher ion release compared to the milled Co-Cr, although no statistically significant differences in surface roughness could be observed among them [2]. In another publication investigating surface roughness on the nanoscale, a rougher surface for the laser melted Co-Cr compared to cast, milled, and laser sintered Co-Cr was demonstrated [27]. With respect to the limited literature regarding surface roughness parameters to Co-Cr in relation to inflammatory response to monocytes, we concluded that the small differences in surface roughness among the materials were negligible [28,29] (Table 2).
Table 2

Results of surface analysis: Sa, Sdr and Sds

Sa (μm) Sdr (%) Sds (1/μm2)



Mean (SD) Mean (SD) Mean (SD)
Cobalt-chromium Wirobond 280® 0.13 (0.06) 4.2 (0.4) 0.22 (0.02)

Remanium® Star 0.13 (0.01) 4.7 (0.7) 0.23 (0.04)

Remanium® Star MDII 0.15 (0.01) 5.8 (0.7) 0.23 (0.04)

Remanium® Star CL 0.13 (0.02) 4.8 (0.3) 0.23 (0.04)

Zirkonzahn® Sintermetall 0.15 (0.01) 5.8 (0.3) 0.21 (0.02)

Titanium CpTi4 0.16 (0.03) 5.2 (1.4) 0.19 (0.01)

Ti-6Al-4V 0.14 (0.01) 3.8 (0.3) 0.21 (0.01)

Mean range differences: Sa = 0.009 to 0.01µm, Sdr = 0.1 to 0.7 %, Sds = 0.01 to 0.02/µm2; P < 0.05.

SD = standard deviation; CpTi4 = commercially pure titanium grade 4; Ti-6Al-4V = titanium alloy grade 23.

Results of surface analysis: Sa, Sdr and Sds Mean range differences: Sa = 0.009 to 0.01µm, Sdr = 0.1 to 0.7 %, Sds = 0.01 to 0.02/µm2; P < 0.05. SD = standard deviation; CpTi4 = commercially pure titanium grade 4; Ti-6Al-4V = titanium alloy grade 23. The results from the present study demonstrated that the cast Co-Cr (Rc) specimen provoked a higher pro-inflammatory cytokine release as compared to the other alloys. Although small amounts of Mo (in W280 and Zz), Si (in W280 and Zz) and Mn (in W280 and Rc) are added to improve the mechanical properties of Co-Cr alloys, no general conclusion between included elements and inflammatory response could be drawn [30,31] (Table 1). According to the previous literature, the cast Co-Cr releases a higher amount of ions compared to laser melted Co-Cr [2,32-34]. It has been suggested that ion release provokes an up- and down- regulation of inflammatory regulators that may cause tissue destruction around dental or orthopaedic implants [7,21,35,36]. In a study investigating metal ions and cytokine expression in saliva from patients with oral lichen planus and dental prostheses, demonstrated a positive correlation between IL-1β and Cr ions [37]. The latter finding was confirmed in the present study, where the IL-1β cytokine was upregulated when cells were exposed to the cast and presintered Co-Cr specimens. It should be noted that comparisons between these studies must be made with caution since ion release in in vivo conditions may be influenced by dietary intake, saliva composition, and the contents of prostheses’ alloy that were not fully declared [37,38]. In cases where the Co-Cr supra-constructions are retained on the implant platform without an abutment, Co-Cr is located deep in the sulcus and may interact and cause a reaction in the periimplant mucosa. Both tooth- and implant-supported supra-constructions manufactured by Co-Cr are, to some extent, exposed to the oral cursive as well as the mucosa, and may release metal ions [2,21,33]. This may induce an inflammatory response with the upregulation of cytokine mediators that may lead to bone destruction around an implant [6,21]. However, further research is needed to determine the role of the material and the specific cytokines in the mechanisms of inflammatory bone loss around dental implants as well as the interplay with bacteria [6,8,39,40]. Within the limitations of the present study, the results showed a general upregulation of the pro- and anti-inflammatory cytokines to the cast Co-Cr compared to the laser melted. Both titanium materials (CpTi4 and Ti-6Al-4V ELI) demonstrated similar cytokine expression levels as the laser melted Co-Cr. The upregulation of cytokine level was not as prominent for the anti-inflammatory cytokines as for the pro-inflammatory cytokines (Figure 2 and 3). In the previous literature, the majority of the studies that have investigated the inflammatory response to implants are related to analyses of pro-inflammatory cytokines [3,6,10,14,15,17,20,21,26,37,41,42]. The present study classifies IL-4 as an anti-inflammatory cytokine that may contribute to inhibit bone resorption [8,36,43]. In other studies IL-4 has been classified as a pro-inflammatory or adaptive immunity cytokine [11,12,26,44]. It has been proposed that IL-4 should be defined as a pleiotropic (polyfunctional) cytokine that acts both as an inhibitor and enhancer for the expression of mediators to osteoblasts, osteoclasts, fibroblasts, and inflammatory cells [8,45]. The multiple roles of specific cytokines display the variety and complexity of ways to understand the inflammatory response. Furthermore, an increased ion release from cast Co-Cr compared to the laser melted, that has been demonstrated in an earlier publication, may also contribute to the upregulation of cytokines [2]. The microstructure of a material is another factor that may affect the ion release and thereby the inflammatory response [32]. Studies have demonstrated that laser melted Co-Cr specimens showed smaller grain size and a more homogeneous and dense structure compared to the cast Co-Cr specimens [46-53]. It has been demonstrated that a rapid cooling and strong temperature gradient in the manufacturing process of laser melted Co-Cr resulted in a more corrosion-resistant microstructure as compared to the procedures of the casting technique [32]. It may be suggested that microstructural differences between laser melted and cast Co-Cr alloys regarding (a) the non-presence of segregation of Co and Cr in laser melted Co-Cr alloys, and (b) the type of secondary phases, results in a decreased ion release from laser melted Co-Cr alloys compared to cast Co-Cr alloys [2,48,54]. In order to further understand the microstructural factors that may contribute to differences in ion release and subsequent cytokine levels between the materials, more research is needed. Despite the limitations of the present study, the significance of basic research is that it contributes to an increased understanding of the potential cellular effects of metal-based dental prostheses. In summary, it can be concluded that an upregulated inflammatory response was mainly observed to the cast Co-Cr alloys. Laser melted Co-Cr and titanium (CpTi4 and Ti-6Al-4V ELI) demonstrated a similar inflammatory response, but one that was lower compared to cast Co-Cr. The null hypothesis was rejected since the cytokine release among the cells exposed to the different materials differed, P < 0.05.

CONCLUSIONS

Within the limitations of the present study, it may be suggested that cast and presintered milled cobalt-chromium alloys provoke a stronger inflammatory response compared to milled and laser melted cobalt-chromium alloys and titanium materials.
  48 in total

1.  Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial.

Authors:  Luigi Canullo; Giampiero Rossi Fedele; Giuliano Iannello; Søren Jepsen
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

2.  Inflammatory cytokine release is affected by surface morphology and chemistry of titanium implants.

Authors:  Anna-Karin Östberg; Ulf Dahlgren; Young-Taeg Sul; Carina B Johansson
Journal:  J Mater Sci Mater Med       Date:  2015-03-17       Impact factor: 3.896

Review 3.  Is marginal bone loss around oral implants the result of a provoked foreign body reaction?

Authors:  Tomas Albrektsson; Christer Dahlin; Torsten Jemt; Lars Sennerby; Alberto Turri; Ann Wennerberg
Journal:  Clin Implant Dent Relat Res       Date:  2013-09-04       Impact factor: 3.932

4.  Effect of Post-Sintering Conditions on the Mechanical Properties of a New Co-Cr Alloy Produced by New Subtractive Manufacturing.

Authors:  Dae-Ho Lee; Takao Hanawa; Seong-Ho Jang; Hyo-Jin Lee; Min-Ho Hong; Bong Ki Min; Tae-Yub Kwon
Journal:  J Nanosci Nanotechnol       Date:  2019-04-01

Review 5.  Biological interactions of dental cast alloys with oral tissues.

Authors:  Gottfried Schmalz; Pauline Garhammer
Journal:  Dent Mater       Date:  2002-07       Impact factor: 5.304

6.  In vitro biocompatibility of CoCrMo dental alloys fabricated by selective laser melting.

Authors:  Yolanda S Hedberg; Bin Qian; Zhijian Shen; Sannakaisa Virtanen; Inger Odnevall Wallinder
Journal:  Dent Mater       Date:  2014-03-02       Impact factor: 5.304

7.  Microstructures and Mechanical Properties of Co-Cr Dental Alloys Fabricated by Three CAD/CAM-Based Processing Techniques.

Authors:  Hae Ri Kim; Seong-Ho Jang; Young Kyung Kim; Jun Sik Son; Bong Ki Min; Kyo-Han Kim; Tae-Yub Kwon
Journal:  Materials (Basel)       Date:  2016-07-20       Impact factor: 3.623

8.  Correlation between Metal Ions and Cytokines in the Saliva of Patients with Oral Lichenoid Lesions.

Authors:  Hye Min Ju; Sun Nyoung Yu; Yong Woo Ahn; Soo Min Ok; Soon Cheol Ahn; Sung Hee Jeong
Journal:  Yonsei Med J       Date:  2021-08       Impact factor: 2.759

Review 9.  Selected aspects of the action of cobalt ions in the human body.

Authors:  Katarzyna Czarnek; Sylwia Terpiłowska; Andrzej K Siwicki
Journal:  Cent Eur J Immunol       Date:  2015-08-03       Impact factor: 2.085

Review 10.  Linkage of Periodontitis and Rheumatoid Arthritis: Current Evidence and Potential Biological Interactions.

Authors:  Rafael Scaf de Molon; Carlos Rossa; Rogier M Thurlings; Joni Augusto Cirelli; Marije I Koenders
Journal:  Int J Mol Sci       Date:  2019-09-13       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.