| Literature DB >> 35211105 |
Cuiqin Li1,2,3, Laping He1,2, Yuedan Hu1,2, Hanyu Liu1,2, Xiao Wang1,2, Li Chen1,2, Xuefeng Zeng1,2.
Abstract
Predicting the number of microorganisms has excellent application in the food industry. It helps in predicting and managing the storage time and food safety. This study aimed to establish a new, simple, and effective model for predicting the number of microorganisms. The dimensional analysis model (DAM) was established based on dimensionless analysis and the Pi theorem. It was then applied to predict the number of Pseudomonas in Niuganba (NGB), a traditional Chinese fermented dry-cured beef, which was prepared and stored at 278 K, 283 K, and 288 K. Finally, the internal and external validation of the DAM was performed using six parameters including R 2, R 2 adj , root mean square error (RMSE), standard error of prediction (%SEP), A f , and B f . High R 2 and R 2 adj and low RMSE and %SEP values indicated that the DAM had high accuracy in predicting the number of microorganisms and the storage time of NGB samples. Both A f and B f values were close to 1. The correlation between the observed and predicted numbers of Pseudomonas was high. The study showed that the DAM was a simple, unified and effective model to predict the number of microorganisms and storage time.Entities:
Keywords: Pi theorem; dimensional analysis; predicting microorganism model; storage time; validation
Year: 2022 PMID: 35211105 PMCID: PMC8861324 DOI: 10.3389/fmicb.2022.820539
Source DB: PubMed Journal: Front Microbiol ISSN: 1664-302X Impact factor: 5.640
FIGURE 1Parameters of NGB (logNT, ST, storagetime, and pH values) obtained at different θ. (A) θ = 278 K, (B) θ = 283 K, and (C) θ = 288 K. NT means observed Pseudomonas number (CFU/g). Error bars represent the standard deviation of three independent samples.
FIGURE 2Effect of Log(θT2/ ST) and Log(pHT) on Log(NT).
FIGURE 3Linear fit for observed and predicted numbers based on DAM for NGB from internal data. (A) Observed and predicted numbers of Pseudomonas; (B) Observed and predicted storage time.
FIGURE 4Linear fit for observed and predicted numbers based on DAM for NGB from external data. (A) Observed and predicted numbers of Pseudomonas; (B) observed and predicted storage times.
FIGURE 5External data: parameters of NGB (logNT, ST, storage time, and pH) obtained at different θ, (A) θ = 278 K, (B) θ = 283 K, (C) θ = 288 K. NT means observed Pseudomonas number (CFU/g). Error bars represent the standard deviation of three independent samples.
Validation parameters for DAM describing the growth of microorganisms or storage time for NGB.
| Sample | Equation | Data | MRE/% | RMSE | %SEP |
|
|
| NGB | Equation 15 (predicted log | Internal | 0.60 | 0.0302 | 2.0838 | 1.0127 | 1.0001 |
| External | 1.60 | 0.0524 | 3.6231 | 1.0228 | 0.9985 | ||
| Equation 16 (predicted storage time) | Internal | 2.83 | 1.4540 | 4.7388 | 1.0423 | 0.9990 | |
| External | 5.31 | 2.8846 | 9.4016 | 1.0941 | 1.0617 |