Literature DB >> 3519892

High count rate first-pass radionuclide angiography using a digital gamma camera.

R Gal, R P Grenier, J Carpenter, D H Schmidt, S C Port.   

Abstract

In this study, first-pass radionuclide angiography (FPRNA) was performed using a digital single-crystal gamma camera. Twenty-nine men and six women (ages 43-80, mean 61 yr) underwent FPRNA in the supine position immediately prior to cardiac catheterization. Total counts/sec in the whole field-of-view in the right ventricular phase were 150,352 +/- 26,006. Background uncorrected counts in the representative cycle were 7,651 +/- 2,527 at end-diastolie and 4,904 +/- 2,314 at end-systolie. A linear correlation between FPRNA left ventricular (LV) ejection fraction and contrast LV ejection fraction gave an r = 0.95 with an s.e.e. of 0.05. Analyses of intra- and interobserver variability gave r = 0.99 and 0.98 and an s.e.e. of 0.02 and 0.03, respectively. Spearman-Rank correlation coefficients between FPRNA and contrast angiographic wall-motion scores were greater than 0.8 for all walls, while sensitivity/specificity were 0.86/0.90, 0.76/1.00, 0.76/1.00 for anterior, apical, and inferior wall-motion abnormalities, respectively. We conclude that satisfactory counting statistics for FPRNA can be obtained with a digital gamma camera, and that accurate and reproducible measurements of global and regional left ventricular function can be obtained with this technique.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3519892

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  11 in total

Review 1.  Measurement of ventricular function with radionuclide techniques.

Authors:  Kim A Williams
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

Review 2.  Measurement of ventricular function with scintigraphic techniques: part I-imaging hardware, radiopharmaceuticals, and first-pass radionuclide angiography.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

3.  First-pass radionuclide angiography.

Authors:  John D Friedman; Daniel S Berman; Salvador Borges-Neto; Sean W Hayes; Lynne L Johnson; Kenneth J Nichols; Robert A Pagnanelli; Steven C Port
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

4.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

5.  Assessment of ventricular function with first-pass radionuclide angiography using technetium 99m hexakis-2-methoxyisobutylisonitrile: a European multicentre study.

Authors:  G Bisi; R Sciagrà; U Büll; K E Britton; C Eilles; D Eissner; K Hahn; H Höffken; K Joseph; J H McKillop
Journal:  Eur J Nucl Med       Date:  1991

6.  Gated planar technetium 99m-labeled sestamibi myocardial perfusion image inversion for quantitative scintigraphic assessment of left ventricular function.

Authors:  K A Williams; L A Taillon
Journal:  J Nucl Cardiol       Date:  1995 Jul-Aug       Impact factor: 5.952

7.  Imaging guidelines for nuclear cardiology procedures. American Society of Nuclear Cardiology. First-pass radionuclide angiography (FPRNA).

Authors: 
Journal:  J Nucl Cardiol       Date:  1996 May-Jun       Impact factor: 5.952

Review 8.  First-pass radionuclide angiocardiography with single-crystal gamma cameras.

Authors:  K Nichols; E G DePuey; A Rozanski
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

9.  The use of iridium-191m for pulmonary blood flow imaging.

Authors:  M Bocher; D Issachar; M Zabari; H Karger; R Chisin
Journal:  Eur J Nucl Med       Date:  1994-05

10.  Feasibility of first-pass radionuclide angiocardiography with a 10-mCi technetium bolus using a single-crystal digital gamma camera: implications for technetium-sestamibi single-day protocols.

Authors:  J P Esquerré; F J Coca; P Gantet; E Ouhayoun
Journal:  Eur J Nucl Med       Date:  1995-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.