Comparison of reports on lung function tests made by chest physicians with those made by a simple computer program.

D M Geddes, M Green, P A Emerson.   

Abstract

The numerical results of 60 sets of pulmonary function tests were submitted to five consultant chest physicians for independent reporting. The chest physicians' reports were compared with the reports generated by the on-line computer reporting system in routine use in the pulmonary function laboratory at Westminster Hospital. There was good agreement between the reports of the chest physicians among themselves and with the computer. The individual reports were compared with the consensus opinions of the physicians and the computer. The computer's decisions differed from the consensus opinion in 4.6% of instances. The comparable figures for the five physicians were respectively 2.9%, 2.9%, 2.9%, 4.0%, and 4.6%. Decisions differing from the consensus were due to mistakes or actual sustained disagreements of opinion. The physicians made more mistakes than the computer even though they were performing under test conditions. They made up for this, however, by producing fewer genuine disagreements from the consensus opinions. It is concluded that in routine day-to-day practice the computer report will be as consistently useful as the chest physicians' reports and more immediately available.

Mesh:

Year:  1978        PMID: 351849      PMCID: PMC470880          DOI: 10.1136/thx.33.2.257

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  5 in total

1.  A computer program for calculation and interpretation of pulmonary function studies.

Authors:  J H Ellis; S P Perera; D C Levin
Journal:  Chest       Date:  1975-08       Impact factor: 9.410

2.  METHODOLOGY FOR COMPUTER MEASUREMENT OF PULMONARY FUNCTION CURVES.

Authors:  E M SHONFELD; J KEREKES; C A RADEMACHER; A L WEIHRER; S ABRAHAM; H SILVER; C A CACERES
Journal:  Dis Chest       Date:  1964-10

3.  A computer system for processing data from routine pulmonary function tests.

Authors:  A I Pack; R McCusker; F Moran
Journal:  Thorax       Date:  1977-06       Impact factor: 9.139

4.  Computer interpretation of ventilatory studies.

Authors:  E P Hoffer; D Kanarek; H Kazemi; G O Barnett
Journal:  Comput Biomed Res       Date:  1973-08

5.  Application of desk-top computer in clinical spirometry. An automatic calculation and diagnosis program.

Authors:  S T Chiang
Journal:  Am Rev Respir Dis       Date:  1972-10
  5 in total
  2 in total

1.  Misclassification of OSA severity with automated scoring of home sleep recordings.

Authors:  R Nisha Aurora; Rachel Swartz; Naresh M Punjabi
Journal:  Chest       Date:  2015-03       Impact factor: 9.410

2.  Computer aided decision making in medicine.

Authors:  D J Spiegelhalter
Journal:  Br Med J (Clin Res Ed)       Date:  1984-09-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.