Literature DB >> 3517037

Comparison of the MicroScan system with the API Staph-Ident system for species identification of coagulase-negative staphylococci.

Z Hussain, L Stoakes, D L Stevens, B C Schieven, R Lannigan, C Jones.   

Abstract

To evaluate the accuracy of the MicroScan System (American Hospital Supply Corp., Sacramento, Calif.) for identification of coagulase-negative staphylococci, we tested 175 clinical isolates of coagulase-negative staphylococci. The results obtained by the MicroScan system were compared with those of the API Staph-Ident system (Analytab Products, Plainview, N.Y.). Forty-three discrepancies between the two systems were resolved by the conventional method of Kloos and Schleifer (W.E. Kloos and K.H. Schleifer, J. Clin. Microbiol. 1:82-88, 1975). The MicroScan and the Staph-Ident systems correctly identified 146 (86.4%) and 154 (88%) of 175 strains, respectively. The API system failed to identify phosphatase-negative Staphylococcus epidermidis. The MicroScan system demonstrated the greatest accuracy in the identification of S. epidermidis and S. saprophyticus, whereas lesser accuracy was achieved with S. hominis, S. warneri, and S. sciuri.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3517037      PMCID: PMC268585          DOI: 10.1128/jcm.23.1.126-128.1986

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  A simple test system for the separation of staphylococci from micrococci.

Authors:  K H Schleifer; W E Kloos
Journal:  J Clin Microbiol       Date:  1975-03       Impact factor: 5.948

2.  Simplified scheme for routine identification of human Staphylococcus species.

Authors:  W E Kloos; K H Schleifer
Journal:  J Clin Microbiol       Date:  1975-01       Impact factor: 5.948

3.  Species identification of coagulase-negative staphylococcal isolates from blood cultures.

Authors:  R H Eng; C Wang; A Person; T E Kiehn; D Armstrong
Journal:  J Clin Microbiol       Date:  1982-03       Impact factor: 5.948

4.  Characterization of clinically significant strains of coagulase-negative staphylococci.

Authors:  G D Christensen; J T Parisi; A L Bisno; W A Simpson; E H Beachey
Journal:  J Clin Microbiol       Date:  1983-08       Impact factor: 5.948

5.  Identification of coagulase-negative staphylococci with the API STAPH-IDENT system.

Authors:  R J Almeida; J H Jorgensen
Journal:  J Clin Microbiol       Date:  1983-08       Impact factor: 5.948

6.  Identification of Staphylococcus species with the API STAPH-IDENT system.

Authors:  W E Kloos; J F Wolfshohl
Journal:  J Clin Microbiol       Date:  1982-09       Impact factor: 5.948

  6 in total
  17 in total

Review 1.  Automated systems for identification of microorganisms.

Authors:  C E Stager; J R Davis
Journal:  Clin Microbiol Rev       Date:  1992-07       Impact factor: 26.132

2.  Reproducibility of API Staph-Ident system identifications of coagulase-negative staphylococci isolated from blood.

Authors:  T L Overman; J K Overley
Journal:  J Clin Microbiol       Date:  1990-11       Impact factor: 5.948

3.  Evaluation of MicroScan Rapid Pos Combo panels for identification of staphylococci.

Authors:  L Stoakes; B C Schieven; E Ofori; P Ewan; R Lannigan; Z Hussain
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

4.  Evaluation of Biolog for identification of members of the family Micrococcaceae.

Authors:  J M Miller; J W Biddle; V K Quenzer; J C McLaughlin
Journal:  J Clin Microbiol       Date:  1993-12       Impact factor: 5.948

5.  Validation of the MicroScan-96 for the species identification and methicillin susceptibility testing of clinical significant coagulase-negative staphylococci.

Authors:  L Patteet; H Goossens; M Ieven
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-08-04       Impact factor: 3.267

6.  Evaluation of screening and commercial methods for detection of methicillin resistance in coagulase-negative staphylococci.

Authors:  Z Hussain; L Stoakes; R Lannigan; S Longo; B Nancekivell
Journal:  J Clin Microbiol       Date:  1998-01       Impact factor: 5.948

Review 7.  Use of enzyme tests in characterization and identification of aerobic and facultatively anaerobic gram-positive cocci.

Authors:  S Bascomb; M Manafi
Journal:  Clin Microbiol Rev       Date:  1998-04       Impact factor: 26.132

8.  Evaluation of five commercial systems for identification of coagulase-negative staphylococci to species level.

Authors:  M Skulnick; M P Patel; D E Low
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-11       Impact factor: 3.267

9.  Four-year prospective study of STAPH-IDENT system and conventional method for reference identification of Staphylococcus, Stomatococcus, and Micrococcus spp..

Authors:  D L Rhoden; J M Miller
Journal:  J Clin Microbiol       Date:  1995-01       Impact factor: 5.948

10.  Comparison of the MicroScan, VITEK 2, and Crystal GP with 16S rRNA sequencing and MicroSeq 500 v2.0 analysis for coagulase-negative Staphylococci.

Authors:  Miyoung Kim; Se Ran Heo; Soon Hee Choi; Hyelin Kwon; Jeong Su Park; Moon-Woo Seong; Do-Hoon Lee; Kyoung Un Park; Junghan Song; Eui-Chong Kim
Journal:  BMC Microbiol       Date:  2008-12-23       Impact factor: 3.605

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.