OBJECTIVE: This study aimed to review studies comparing outcomes following percutaneous coronary intervention (PCI) in saphenous vein grafts (SVG) with and without embolic protection devices (EPD).Entities:
Keywords: embolic protection devices; meta-analysis; percutaneous coronary intervention; saphenous vein graft; systematic review
Year: 2022 PMID: 35127842 PMCID: PMC8814455 DOI: 10.3389/fcvm.2021.726579
Source DB: PubMed Journal: Front Cardiovasc Med ISSN: 2297-055X
Figure 1PRISMA flow chart showing the selection of studies for the current review (n = 11).
Characteristics of the included studies, N = 11.
|
|
|
|
|
|
|
|
|
|
| |
|---|---|---|---|---|---|---|---|---|---|---|
| 1. | Baim et al. ( | USA | RCT | 406 | 395 | Guardwire | EPD = 68 | Death, MACE, late MI | 1 | High |
| 2. | Brennan et al. ( | USA | NCDR CathPCI | 10,432 | 38,893 | SpideRX ( | EPD = 75 | Death, MACE, periprocedural MI, late MI, TVR | 36 | High |
| 3. | Dixon et al. ( | USA | RCT | 173 | 185 | TRAP vascular filter system | EPD = 69.9 | Death, MACE, late MI, TVR | 1 | High |
| 4. | Golwala et al. ( | USA | Retrospective | 93 | 71 | Proxis (7%), Filterwire (55%), Spider (35%), Guardwire (1%) | EPD = 65.4 | Death, MACE, periprocedural MI, late MI, TVR | 12 | High |
| 5. | Iqbal et al. ( | Canada | British columbia cardiac registry | 96 | 1,263 | Filterwire | EPD = 74 | Mortality, TVR | 24 | High |
| 6. | Lavi et al. ( | Canada | Prospective | 198 | 175 | Not provided | EPD = 70.4 | Death, MACE, periprocedural MI, late MI, TVR | 36 | High |
| 7. | Matar et al. ( | USA | Retrospective | 108 | 94 | Not provided | EPD = 69 | Death, MACE, late MI, TVR | 1 | High |
| 8. | Sadr-Ameli et al. ( | Iran | Prospective | 22 | 128 | Not provided | EPD = 63.2 | Death, MACE, periprocedural MI, late MI, TVR | 6 | High |
| 9. | Shoaib et al. ( | UK | Retrospective | 2,912 | 17,730 | Spider (45%) | EPD = 71 | Death and MACE | 48 | High |
| 10. | Valle et al. ( | USA | Retrospective | 2,281 | 2,401 | Filterwire | EPD = 69.2 | Death | 1 | High |
| 11. | Wańha et al. ( | Poland | Multicenter registry | 190 | 602 | Spider FXTM (50%), FilterWire EZ (29%), EmboShield® (8%), Defender (7%), RX | EPD = 70 | Death, MACE, late MI, TVR | 12 | High |
NA, not available; RCT, randomized controlled trial; USA, United States of America; UK, United Kingdom; EPD, embolic protection devices; MACE, major adverse cardiac event; MI, myocardial infarction;
indicate the use of Newcastle Ottawa scale for quality assessment.
Figure 2Forest plot showing the difference in mortality between patients with and without embolic protection devices (EPD) following percutaneous coronary intervention (PCI) on saphenous vein grafts (SVG) (n = 11).
Figure 3Forest plot showing the difference in target vessel revascularization (TVR) between patients with and without EPD following PCI on SVG (n = 7).
Figure 4Forest plot showing the difference in periprocedural myocardial infarction (MI) between patients with and without EPD following PCI on SVG (n = 4).
Figure 5Forest plot showing the difference in late MI between patients with and without EPD following PCI on SVG (n = 7).
Figure 6Forest plot showing the difference in major adverse cardiovascular events (MACE) between patients with and without EPD.