BACKGROUND: Methylene blue (MB) alone or combined with 99mtechnetium-labeled sulphur colloid (Tc99m) or indocyanine green (ICG) is widely used for sentinel lymph node biopsy (SLNB) of early-stage breast cancer in developing countries and regions. However, studies investigating the effectiveness of MB combined with another tracer have produced heterogeneous results. The purpose of this network meta-analysis (NMA) was to evaluate the detection rate of MB alone, MB + Tc99m, and MB + ICG, and to examine the differences between the 3 methods. METHODS: We conducted a comprehensive electronic literature search on the PubMed, Embase, Web of Science, CNKI, and Wanfang Data databases from inception to October 2021. The meta-analysis included 7,498 patients in 49 studies. The risk of bias for each study was independently assessed as low, moderate, or high using criteria adapted from the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Fixed- and random-effects models were used to calculate pooled estimates. Mixed-comparison analysis using random-effects models. We assessed statistical heterogeneity by I2 statistics and evaluated publication bias using Begg's test. RESULTS: The identification rate (IR), false-negative rate (FNR), sensitivity (SEN), and accuracy rate (AR) using MB + Tc99m were 96%, 7%, 93%, and 96%, respectively; the IR, FNR, SEN, and AR using MB + ICG were 97%, 7%, 93%, and 97%, respectively. The NMA found that IR and AR between MB + ICG and MB + Tc99m was OR =1.37 (95% CI: 0.41-4.20) and OR =1.33 (95% CI: 0.56-3.32), respectively. DISCUSSION: Our results are similar to those of most previous studies, and meta-analysis showed that the MB + Tc99m or MB + ICG mapping methods can be used to obtain higher IR and lower FNR than MB alone. Our NMA showed no statistical significance between MB + Tc99m and MB + ICG with IR and AR. Both MB + Tc99m and MB + ICG can be used as effective mapping methods in SLNB of early-stage breast cancer to improve the detection rate. 2021 Translational Cancer Research. All rights reserved.
BACKGROUND: Methylene blue (MB) alone or combined with 99mtechnetium-labeled sulphur colloid (Tc99m) or indocyanine green (ICG) is widely used for sentinel lymph node biopsy (SLNB) of early-stage breast cancer in developing countries and regions. However, studies investigating the effectiveness of MB combined with another tracer have produced heterogeneous results. The purpose of this network meta-analysis (NMA) was to evaluate the detection rate of MB alone, MB + Tc99m, and MB + ICG, and to examine the differences between the 3 methods. METHODS: We conducted a comprehensive electronic literature search on the PubMed, Embase, Web of Science, CNKI, and Wanfang Data databases from inception to October 2021. The meta-analysis included 7,498 patients in 49 studies. The risk of bias for each study was independently assessed as low, moderate, or high using criteria adapted from the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Fixed- and random-effects models were used to calculate pooled estimates. Mixed-comparison analysis using random-effects models. We assessed statistical heterogeneity by I2 statistics and evaluated publication bias using Begg's test. RESULTS: The identification rate (IR), false-negative rate (FNR), sensitivity (SEN), and accuracy rate (AR) using MB + Tc99m were 96%, 7%, 93%, and 96%, respectively; the IR, FNR, SEN, and AR using MB + ICG were 97%, 7%, 93%, and 97%, respectively. The NMA found that IR and AR between MB + ICG and MB + Tc99m was OR =1.37 (95% CI: 0.41-4.20) and OR =1.33 (95% CI: 0.56-3.32), respectively. DISCUSSION: Our results are similar to those of most previous studies, and meta-analysis showed that the MB + Tc99m or MB + ICG mapping methods can be used to obtain higher IR and lower FNR than MB alone. Our NMA showed no statistical significance between MB + Tc99m and MB + ICG with IR and AR. Both MB + Tc99m and MB + ICG can be used as effective mapping methods in SLNB of early-stage breast cancer to improve the detection rate. 2021 Translational Cancer Research. All rights reserved.
Entities:
Keywords:
99mtechnetium-labeled sulphur colloid (Tc99m); Breast cancer; indocyanine green (ICG); meta-analysis; methylene blue (MB); sentinel lymph node biopsy (SLNB)
Breast cancer is the most common malignant tumor occurring in women worldwide. In China, the incidence of breast cancer increases every year (1). The eighth edition of the American Joint Committee on Cancer (AJCC)’s Cancer Staging Manual provides comprehensive advice on the staging, prognosis, and treatment of cancer, and is considered more accurate than traditional anatomical staging (2). Axillary lymph node (ALN) status is an important factor in breast cancer staging and prognosis; therefore, the accurate evaluation of ALN status is essential for the formulation an appropriate treatment plan. Sentinel lymph node biopsy (SLNB) has become the standard staging scheme for patients with cN0 early-stage breast cancer (3,4). Improving the identification rate (IR), sensitivity (SEN), and accuracy rate (AR) of SLNB while simultaneously reducing the false-negative rate (FNR) is a critical concern for surgeons, and the selection of tracers is key to the success of SLNB.Common tracers for SLNB include blue dye, radioisotope, and fluorescence, or blue dye combined with radioisotope or fluorescence. The combination of radioisotope and blue dyes, such as patent blue or isosulfan blue, is considered the standard mapping method worldwide. Meanwhile, the combined use of indocyanine green (ICG) and blue dye has gradually become more frequent in clinical practice as a means of improving detection rates (5). However, hospitals in many developing countries, including China, have limited access to patent blue or isosulfan blue and are unable to provide the personnel and equipment required for radioisotope use. Consequently, with regard to the selection of blue dye, the 2021 Chinese Society of Breast Surgery (CSBrS) practice guidelines recommend blue dye alone or fluorescence alone as class IA, radioisotope alone or the combination of radioisotope and blue dye as class IB (6).Researchers have sought to improve the detection rate of SLNB by combining different tracers. In previous studies, methylene blue (MB) combined with 99mtechnetium-labeled sulphur colloid (MB + Tc99m) and MB combined with ICG (MB + ICG) showed certain advantages over MB alone. However, as these studies were small in scale and technically heterogeneous, they did not provide clear results. The detection rates of MB alone, MB + Tc99m, and MB + ICG are therefore uncertain. We thus sought to evaluate the detection rates of these 3 methods and to examine their differences using a network meta-analysis (NMA).We present the following article in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) reporting checklist (available at https://dx.doi.org/10.21037/tcr-21-1239), and our protocol was registered with the International Platform of Registered Systematic Review and Meta-Analysis Protocols (INPLASY; registration no. INPLASY202150107).
Methods
Literature retrieval strategy
This meta-analysis was reported and screened according to the PRISMA Guidelines (7). We conducted a comprehensive electronic literature search on the PubMed, Embase, Web of Science, CNKI, and Wanfang Data databases from inception to October 2021. The following search terms from the Medical Subject Headings (MeSH) vocabulary were used: “Breast Neoplasms”, “Methylene Blue”, and “Sentinel Lymph Node Biopsy”. The Chinese databases were searched with the equivalent Chinese keywords to those from the English databases. In addition, the reference lists of previous reviews were also reviewed for plausible articles. Letters, editorials, case reports, and reviews were excluded from the study. We did not attempt to obtain any unpublished research. Any disagreements were resolved through discussion.
Eligibility criteria
Inclusion criteria
The inclusion criteria for literature were the following: all patients examined were diagnosed with early-stage breast cancer by cytology or histopathology; at least 1 group in the study underwent MB alone, MB + ICG, or MB + Tc99m as a mapping method for SLNB; some or all of the IR, SEN, AR, and FNR indicators could be extracted or calculated from the study; the study was a cohort study or case–control study; and the study publication language was English or Chinese.
Exclusion criteria
Studies that included clinical node-positive patients (cN+), distant metastasis, or surgical contraindications for SLNB were excluded. Patients who received neoadjuvant chemotherapy or radiotherapy before SLNB were also excluded. Studies that used other blue dyes, such as patent blue or isosulfan blue, were excluded. In terms of outcomes, studies that lacked available data were excluded. Studies that consisted of letters, editorials, case reports, or reviews were excluded. For studies with overlapping patients or repeated reports, only studies with the largest number of patients were included.The retrieval strategy is shown in .
Figure 1
The flowchart of study selection for this meta-analysis.
The flowchart of study selection for this meta-analysis.
Selection process and data collection process
The data were extracted by 2 independent reviewers (HJL and MSS) and verified for accuracy by 2 other reviewers. Any disagreements were resolved through discussion. Summaries of study characteristics included the first author, publication year, study origin, the age of the patients, the tumor stage, the mapping method for SLNB, and the number of patients enrolled.
Risk of bias assessment
The risk of bias in the studies was assessed with Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2), a standardized tool for evaluating the quality of diagnostic accuracy studies (8). QUADAS-2 contains 4 domains for assessing the risk of bias: patient selection, index test, reference standard, and flow and timing. Signaling questions (yes/no/unclear) are used to assess the risk of bias in each domain. If the answers to all signaling questions in a domain are yes, then the risk of bias can be judged as low. If any signaling question is answered no, then the potential for bias exists. Review authors must then use the guidelines developed in phase 2 to judge the risk of bias. The “unclear” answer is used when insufficient data are reported to allow a judgment. The first 3 domains, patient selection, index test, and reference standard, are further assessed in terms of the applicability of the study to the research question. All studies in this meta-analysis were independently analyzed by 2 independent reviewers (HJL and MSS). The questions adopted in our review are listed in Table S1 and the outcome in our review are listed in Table S2.
Statistical analysis
In this study, IR was defined as the number of patients for whom SLNs were successfully identified divided by the total number of patients who underwent SLNB. AR was defined as the proportion of people whose ALN status were correctly predicted by SLNB. The results of each successfully identified SLN were further classified as true positive (TP), true negative (TN), or false negative (FN). We then evaluated 2 diagnostic parameters: FNR [FN/(FN + TP)] and sensitivity [TP/(TP + FN)].The R meta4diag package version 3.6.3 (https://www.r-project.org) was used to perform the pooled analyses of FNR and SEN, which were considered to be diagnostic parameters in this study. The pooled analyses of IR and AR, which were single proportions, were conducted using the “metaprop” function in the R meta package. The logit transformation was implemented to calculate overall proportions. The method of inverse variance was conducted for the pooling of individual studies. The inconsistency statistic (I2) was used to evaluate the heterogeneity among the studies. The random-effects model was adopted if I2 was >50%; otherwise, the fixed effects model was used. Potential publication bias was determined by a funnel plots and assessed using Begg’s test.Mixed-comparison analysis using random-effects models, i.e., the NMA was conducted for comparison of IR and AR across the tracers. The NMA was carried out with a random-effects model of the Bayesian framework analysis using the “GeMTC” R package, which includes the software JAGS 4.3.0. Odds ratios (OR) and their 95% CI were applied for the comparisons of IR and AR between the 3 mapping methods.In this study, all statistical tests were 2 sided, and P values of less than 0.05 were deemed significant.
Results
Basic characteristics of included studies
Our meta-analysis included 7,498 patients in 49 studies published between inception and 2021, of which 43 studies were from China, 4 from India, and 1 each from Turkey and Italy. At least 1 group of patients in 26 studies were subjected to MB + Tc99m in SLNB, and at least 1 group of patients in 35 studies were subjected to MB + ICG in SLNB. lists the basic characteristics of 49 studies, while the retrieval strategy is shown in .
Table 1
Characteristics of the Included Studies
No.
Study
Year
Origin
Age [year, range]
Tumor stage
The mapping method
No. of patients
1
Tang et al. (9)
2005
China
45a [29–65]
T1-2
MB + Tc99m
83
MB
38
2
Zhao et al. (10)
2005
China
NR
T1-3
MB + Tc99m
38
3
Lu et al. (11)
2006
China
48.7 [32–73]
T1-2
MB + Tc99m
120
4
D’Eredita et al. (12)
2006
Italy
57 [27–87]
T1-2
MB + Tc99m
40
57.6 [40–78]
MB
40
5
Liu et al. (13)
2007
China
50±10
T1-2
MB + Tc99m
60
52±12
MB
104
6
Lin et al. (14)
2007
China
44±15.8 [33–74]
T1-2
MB + Tc99m
112
7
Somashekhar et al. (15)
2008
India
52 [24–82]
T1-2
MB + Tc99m
100
8
Wang et al. (16)
2009
China
52 [34–78]
T1-2
MB + Tc99m
37
MB
34
9
Chen et al. (17)
2009
China
46 [32–58]
T1-2
MB + Tc99m
13
MB
7
10
Yang et al. (18)
2010
China
45 [24–73]
T1-2
MB + Tc99m
109
11
Liu et al. (19)
2010
China
52.7 [36–75]
T1-2
MB + Tc99m
36
12
Chen et al. (20)
2011
China
31–72
T1-2
MB + Tc99m
31
13
Coskun et al. (21)
2012
Turkey
49.8 [27–74]
T(NR)
MB + Tc99m
47
MB
53
14
Lu et al. (22)
2012
China
45a [26–76]
T1-2
MB + Tc99m
65
15
Tian et al. (23)
2012
China
48a [19–85]
T1-2
MB + Tc99m
199
MB
199
16
Cao et al. (24)
2014
China
52a [29–81]
T1-2
MB + ICG
107
MB
107
17
Zhang et al. (25)
2015
China
45.6±8.5 [27–68]
T1-2
MB + Tc99m
40
18
Ji et al. (26)
2015
China
53.00±11.2 [28–71]
T1-3
MB + ICG
65
19
Lei et al. (27)
2015
China
22–80
T1-2
MB + Tc99m
195
20
Yuan et al. (28)
2016
China
48 [22–77]
T1-2
MB + Tc99m
52
MB + ICG
52
21
Zhang et al. (29)
2016
China
NR
T1-2
MB + ICG
131
MB
145
22
Liu et al. (30)
2016
China
50.21±8.73
T1-2
MB + ICG
62
49.73±9.60
MB
62
23
Cui et al. (31)
2016
China
49.58±6.39 [28–71]
T1-2
MB + ICG
100
50.11±6.80 [26–75]
T1-2
MB
100
24
Tang et al. (32)
2016
China
45.6±12.9
T(NR)
MB + ICG
95
46.2+15.9
T(NR)
MB
65
25
Zhang et al. (33)
2016
China
NR
T1-2
MB + ICG
131
MB
145
26
Guo et al. (5)
2017
China
52 [33–74]
T1-2
MB + ICG
198
MB
198
27
Ji et al. (34)
2017
China
53±11.2
T1-3
MB + ICG
65
28
Heng et al. (35)
2017
China
NR
T1-2
MB + ICG
46
MB
74
29
Sun et al. (36)
2017
China
NR
T(NR)
MB + ICG
85
MB
85
30
Yuan et al. (37)
2019
China
52.6±10.8
T1-3
MB + ICG
245
MB
38
31
Agarwal et al. (38)
2018
India
NR
T(NR)
MB + Tc99m
78
32
Shen et al. (39)
2018
China
47.8±10.8
T1-2
MB + ICG
374
47.2±9.7
MB
149
33
Li et al. (40)
2018
China
54.3+1.6
T1-2
MB + ICG
85
54.1±1.8
MB
85
34
Zhang et al. (41)
2018
China
47.52±5.78
T1-3
MB + ICG
136
48.52±6.30
MB
132
35
Lei et al. (42)
2015
China
63.7 [61–69]
T1-2
MB + ICG
63
36
Gupta et al. (43)
2020
India
54.5 [53.5±11.05]
T1-2
MB + Tc99m
30
53.5 [56.6±11.26]
MB
30
37
Qin et al. (44)
2019
China
NR
T1-3
MB + ICG
60
MB
60
38
Zhou et al. (45)
2019
China
46.9±15
T1-3
MB + ICG
316
39
Zhu et al. (46)
2019
China
46.3
T1-2
MB + ICG
105
48.3
MB
101
40
Zhu et al. (47)
2019
China
46.2±15.9 [33–74]
T(NR)
MB + ICG
95
45.6±12.9 [32–75]
MB
65
41
Zhao et al. (48)
2019
China
47.53±5.45
T(NR)
MB + ICG
86
48.02±5.27
MB
86
42
Liu et al. (49)
2019
China
52.5±17.5
T1-2
MB + ICG
70
52.3±17.4
MB
70
43
Zhou et al. (50)
2019
China
52.8 [27–78]
T(NR)
MB + ICG
140
MB
140
44
Gong et al. (51)
2019
China
NR
T1-2
MB + Tc99m
43
45
Huang et al. (52)
2019
China
20–70
T1-2
MB + ICG
20
46
Bai et al. (53)
2020
China
52.4±9.8
T1-2
MB + ICG
57
53.1±8.4
MB
57
47
Huang et al. (54)
2020
China
51.8±5.2
T1-2
MB + ICG
50
50.6±4.9
MB
50
48
Zhang et al. (55)
2021
China
30–77 [M46.5]
T1-2
MB + ICG
197
MB
218
49
Fang et al. (56)
2021
China
NR
T1-2
MB + Tc99m
92
MB
92
a, Median. NR, no record; MB, methylene blue; ICG, indocyanine green; Tc99m, 99m Technetium-labeled Sulphur Colloid.
a, Median. NR, no record; MB, methylene blue; ICG, indocyanine green; Tc99m, 99m Technetium-labeled Sulphur Colloid.
Identification Rate
IR with MB + Tc99m
Twenty-two studies reported the IR, and with low heterogeneity (I2=19%, Pheterogeneity=0.21). A fixed-effects model was used to estimate the IR with MB + Tc99m, with a result of 96% (95% CI: 95–97%; ).
Figure 2
The identification rate of MB + Tc99m and MB + ICG. (A) A fixed-effects model was used to estimate the IR with MB + Tc99m. (B) A fixed-effects model was used to estimate the IR with MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; IR, identification rate.
The identification rate of MB + Tc99m and MB + ICG. (A) A fixed-effects model was used to estimate the IR with MB + Tc99m. (B) A fixed-effects model was used to estimate the IR with MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; IR, identification rate.
IR with MB + ICG
Twenty-eight studies reported the IR, and with low heterogeneity (I2=0%, Pheterogeneity=0.74). A fixed-effects model was used to estimate the IR with MB + ICG, with a result of 97% (95% CI: 97–98%; ).
False-negative rate
Seventeen studies reported FNR that ranged from 0% to 14%. The summary estimates of FNR with MB + Tc99m were 7% (95% CI: 5–10%; ). Eight studies reported FNR that ranged from 3% to 11%. The summary estimates of FNR with MB + ICG were 7% (95% CI: 4–10%; ).
Figure 3
The false-negative rate of MB + Tc99m and MB + ICG. (A) The summary estimates of the false-negative rate with MB + Tc99m. (B) The summary estimates of the false-negative rate with MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; TP, true positive; FP, false positive; FN, false negative; TN, true negative.
The false-negative rate of MB + Tc99m and MB + ICG. (A) The summary estimates of the false-negative rate with MB + Tc99m. (B) The summary estimates of the false-negative rate with MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; TP, true positive; FP, false positive; FN, false negative; TN, true negative.
Sensitivity
Seventeen studies reported SEN that ranged from 86% to 96%. The summary estimates of SEN with MB + Tc99m were 93% (95% CI: 90–95%; ). Eight studies reported SEN that ranged from 89% to 97%. The summary estimates of SEN with MB + ICG were 93% (95% CI: 90–96%; ).
Figure 4
The Sensitivity of MB + Tc99m and MB + ICG. (A) The summary estimates of sensitivity with MB + Tc99m. (B) The summary estimates of sensitivity with MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; TP, true positive; FP, false positive; FN, false negative; TN, true negative.
The Sensitivity of MB + Tc99m and MB + ICG. (A) The summary estimates of sensitivity with MB + Tc99m. (B) The summary estimates of sensitivity with MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; TP, true positive; FP, false positive; FN, false negative; TN, true negative.
Accuracy
Using the random-effects model to estimate the AR with MB + Tc99m produced a result of 96% (95% CI: 94–97%, I2=0%; Pheterogeneity =0.86; ). Using the fixed-effects model to estimate the AR with MB + ICG produced a result of 97% (95% CI: 96–98%; I2=0%, Pheterogeneity =0.88; ).
Figure 5
The Accuracy of MB + Tc99m and MB + ICG. (A) A random-effects model was used to estimate the AR with MB + Tc99m, with a result of 96% (95% CI: 94–97%; I2=0%). (B) A fixed-effects model was used to estimate the AR with MB + ICG, with a result of 97% (95% CI: 96–98%, I2=0%) of MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; AR, accuracy rate.
The Accuracy of MB + Tc99m and MB + ICG. (A) A random-effects model was used to estimate the AR with MB + Tc99m, with a result of 96% (95% CI: 94–97%; I2=0%). (B) A fixed-effects model was used to estimate the AR with MB + ICG, with a result of 97% (95% CI: 96–98%, I2=0%) of MB + ICG. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green; AR, accuracy rate.
Network meta-analysis
We wanted to simultaneously assess and compare the detection rate among the tracer methods of MB, MB + Tc99m, and MB + ICG. However, studies directly comparing MB + Tc99m and MB + ICG are scarce. We found that 31 of the 49 studies included at least 2 groups of patients who used MB alone and MB + Tc99m or MB + ICG. We therefore conducted an NMA, in pairwise comparison: if MB participated in the comparison, then MB was taken as the reference; otherwise, MB + Tc99m was taken as the reference.Mixed-comparison analysis using random-effects models was conducted for comparison of IR and AR across three tracers. Compared with MB alone, MB + Tc99m (OR, 4.66; 95% CI: 2.19–10.08) and MB + ICG (OR, 6.17; 95% CI: 4.02–10.29) contributed to higher IR. No statistical significance was found in comparison between MB + Tc99m and MB + ICG (OR, 1.33; 95% CI: 0.56–3.32). With regard to AR, significant difference was only observed between MB and MB + ICG (OR, 2.89; 95% CI: 1.51–5.75), indicating a higher AR when using MB + ICG as the tracer. No significant difference was found in comparison between MB and MB + Tc99m (OR, 2.12; 95% CI: 0.84–5.81), or between MB + Tc99m and MB + ICG (OR, 1.37; 95% CI: 0.41–4.20).gives the estimated mean difference in accuracy rate (top right) and identification rate (bottom left) between each combination of mapping methods obtained from mixed-comparison models.
Table 2
Mixed-comparison analysis for comparison of accuracy rate (top right) and identification rate (bottom left) across the three tracers
Mapping method
MB
MB + Tc99m
MB + ICG
MB
–
2.12 (0.84–5.81)
2.89 (1.51–5.75)
MB + Tc99m
4.66 (2.19–10.08)
–
1.37 (0.41–4.20)
MB + ICG
6.17 (4.02–10.29)
1.33 (0.56–3.32)
–
Above the leading diagonal are the estimates of the mean difference in accuracy rate (95% CI), and below the leading diagonal are the estimates of the mean difference in identification rate. Results are presented as odds ratios and 95% confidence intervals. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green.
Above the leading diagonal are the estimates of the mean difference in accuracy rate (95% CI), and below the leading diagonal are the estimates of the mean difference in identification rate. Results are presented as odds ratios and 95% confidence intervals. MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green.
Quality assessment of included studies and publication bias
QUADAS-2 was used to assess the quality of each study, and these results are listed in Table S2. All the studies had a high risk of patient selection bias, as they had a case–control design. Some studies had a high risk or an unclear risk of flow and timing bias, mainly due to the advancement of surgical treatment methods for breast cancer and not all patients having received axillary lymph node dissection (ALND). All other risks were rated as low.Since the number of articles that each research indicator was reported were varied, we used IR, which was reported in the highest number of studies, to evaluate publication bias. The left and right sides in the IR funnel plot are nearly symmetrical, which suggests that there was a low possibility of publication bias (). The Begg’s test values of IR using MB + Tc99m and MB + ICG were P=0.17 and P=0.04, respectively, which suggests that there also was a low possibility of publication bias of MB + ICG.
Figure 6
Funnel plot used to assess the effects of publication bias on the IR of MB + Tc99m or MB + ICG. (A) The funnel plot of IR of MB + Tc99m. (B) The funnel plot of IR of MB + ICG. IR, identification rate; MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green.
Funnel plot used to assess the effects of publication bias on the IR of MB + Tc99m or MB + ICG. (A) The funnel plot of IR of MB + Tc99m. (B) The funnel plot of IR of MB + ICG. IR, identification rate; MB, methylene blue; Tc99m, 99m technetium-labeled sulphur colloid; ICG, indocyanine green.
Discussion
The National Comprehensive Cancer Network (NCCN) and other guidelines agree that SLNB should be the standard method used for ALN staging in cN0 early-stage breast cancer, and that patients who are SLNB negative can be exempted from ALND (4,6,57-60). As a common tracer for SLNB, blue dye has been used widely in clinical practice, either alone or in combination with other tracers. The standard blue dyes, patent blue or isosulphan blue, combined with radioisotope tracers is the preferred trace method recommended by the American Society of Clinical Oncology (ASCO) for SLNB (61). However, for reasons involving the availability of drugs and health economics, these two standard tracers cannot be used clinically in many developing countries, including China.Studies have demonstrated that the IR and FNR of MB used as a substitute for blue dye in SLNB show no clinical or statistical differences when compared with isosulphan blue (62). A meta-analysis of 18 studies from 2000 to 2017 found that when MB alone was used, the IR was 91% and the FNR was 13%, with a FNR of <10% reported in the past 5 years. These rates conform to the recommended standards of the American Society of Breast Surgeons (ASBrS) (63). MB alone is therefore a safe and effective alternative to standard blue dyes in the clinical practice of SLNB.To further improve IR and reduce FNR, MB has been combined with other tracers, including radioisotopes and fluorescent tracers, which are now used widely in clinical practice. Previous systematic reviews and meta-analyses have investigated the use of MB, ICG, and Tc99m in SLNB. Wang et al. (64) conducted a meta-analysis of 15 studies from China. The results showed that the detection rate, number of detections, sensitivity, and specificity of MB + ICG were significantly increased compared with MB alone, while the FNR decreased significantly. A systematic review published by Kim et al. (65), which included 69 studies investigating SLNB and ALND of early-stage breast cancer, concluded that the dual-tracer mapping method had a higher IR compared with radioisotope or blue dye alone.The present study evaluated studies that included both MB and MB + Tc99m or MB + ICG. Our NMA showed that the IR, FNR, SEN, and AR using MB + Tc99m were 96%, 7%, 93%, and 96%, respectively, while the IR, FNR, SEN, and AR using MB + ICG were 97%, 7%, 93%, and 97%, respectively. These results are superior to the IR and FNR of the MB single-tracer mapping method reported in previous literature (63).IR and FNR are important indicators for evaluating the effectiveness of the tracer in SLNB. It is important to note that many factors can influence IR; for example, research has shown that experienced surgeons can achieve a 95.6% IR with blue dye alone (66). However, this meta-analysis suggests that MB combined with Tc99m or ICG can achieve a higher overall IR, which is consistent with the conclusions of studies using other blue dyes combined with radioisotopes or fluorescent tracers (67-69).With respect to FNRs, the ASBrS previously stated that an FNR below 5% could only be accepted when the AR was greater than 95% (70). However, most recent studies have reported an FNR between 5% and 10%. Our research found that the FNR of both MB + Tc99m and MB + ICG was 7%. Therefore, in terms of clinical practice, the dual-tracer mapping method has significant advantages compared with the use of MB alone, which was shown to have a FNR of 13% in a previous meta-analysis. Wong et al. (71) found that when 1 SLN was obtained, the FNR was 14.3%, and that when 2 or more SLNs were obtained, the FNR was 4.3%. Among the 40 studies we included that reported the number of SLNs, only 6 studies reported fewer than 2 SLNs after using MB + Tc99m or MB + ICG. However, it should be noted that not all studies clearly indicated that the identification of SLN involved intraoperative pathological evaluation, and that the studies demonstrated differences in the pathological evaluation of positive lymph nodes. Therefore, we believe that the FNR of MB + Tc99m or MB + ICG is higher than 5% or 4.3%, as the studies in the meta-analysis included some retrospective studies of small samples which did not report the number of SLNs obtained, the pathological evaluation criteria, or whether or not intraoperative pathological evaluation occurred.When comparing MB + Tc99m and MB + ICG, MB + ICG has some advantages over MB + Tc99m in IR and AR. Compared with the limitations radionuclide use in clinical practice, such as the high requirements of personnel qualification and management, the high price of equipment and tracers, the difficulty of storage, and the potential radioactive damage to patients and staff, the use of ICG is easier to promote. The findings of this study provide evidence-based support for the clinical application of MB + ICG.Although no significant heterogeneity was found in this study, the AR (I2=61%, P<0.01) using MB + Tc99m demonstrated a degree of heterogeneity. Despite the utility of sensitivity analysis and meta regression, the origin of the heterogeneity could not be thoroughly traced. Many of the studies included in this meta-analysis were retrospective studies of relatively low quality. In terms of publication bias, our application of Begg’s tests using the IR of MB + Tc99m (P=0.17) or MB + ICG (P=0.04) show less possibility of publication bias; meanwhile, potential bias may exist due to the tendency for positive results to be published and our strict inclusion criteria. This study also limited the publication language to English or Chinese, so publication bias cannot be totally excluded.This evidence-based study has demonstrated that the MB single-tracer method can be used safely in clinical practice, especially in areas where access to other tracers is limited (72). Our meta-analysis showed that the MB + Tc99m or MB + ICG mapping methods can be used to obtain higher IR and lower FNR than MB alone. Our NMA showed no statistical significance between MB + Tc99m and MB + ICG with IR and AR.
Authors: Armando E Giuliano; Karla V Ballman; Linda McCall; Peter D Beitsch; Meghan B Brennan; Pond R Kelemen; David W Ollila; Nora M Hansen; Pat W Whitworth; Peter W Blumencranz; A Marilyn Leitch; Sukamal Saha; Kelly K Hunt; Monica Morrow Journal: JAMA Date: 2017-09-12 Impact factor: 56.272
Authors: S P Somashekhar; S Zaveri Shabber; K Udupa Venkatesh; K Venkatachala; M M Vasan Thirumalai Journal: Indian J Surg Date: 2008-07-24 Impact factor: 0.656