Literature DB >> 15498633

Blue dye versus combined blue dye-radioactive tracer technique in detection of sentinel lymph node in breast cancer.

Z Radovanovic1, A Golubovic, A Plzak, B Stojiljkovic, D Radovanovic.   

Abstract

BACKGROUND: Sentinel lymph node biopsy in breast cancer can be used to select patients in which axillary lymph node dissection could be avoided. In this study we compared the value of two methods for identification of sentinel node (SN) using either only blue dye or combination of blue dye and radioactive tracer.
MATERIAL AND METHODS: All patients were women with clinically T(1-2)N(0)M(0) breast cancer. They were randomized into two groups. In Group A (50 patients) SN marking was performed only with blue dye and in Group B (100 patients) combined SN marking with blue dye and radiotracer was done. We used 2 ml of blue dye Patentblau V (Byk Gulden). Radiotracer was Antimony sulfide marked with Tc 99m and of 0.3 mCy (11.1 MBq) activity. Application method of both contrasts was peritumoral. After SN biopsy all patients underwent mastectomy or conservative surgery with axillary lymph node dissection of levels I and II.
RESULTS: In Group A mean of 1.7 SNs were identified (median 1, range 1-4). False-negative rate in this group was 3/17 (17.6%) with negative-predictive value 20/23 (86.9%), sensitivity 14/17 (82%), specificity 20/33 (60%) and accuracy 34/50 (68%). In Group B mean number of SNs excised per case was 1.6 (median 1, range 1-5). False-negative rate was 2/44 (4.5%), negative-predictive value 41/43 (95.3%), sensitivity 42/44 (95%), specificity 41/56 (73%) and accuracy 83/100 (83%). The combination technique was significantly superior to blue-dye alone technique for negative-predictive value (p=0.033) and overall accuracy (p=0.048).
CONCLUSIONS: The prediction of axillary lymph node status in breast cancer patients using combined technique has significantly higher accuracy than marking of SN with blue dye alone and therefore should be preferred.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15498633     DOI: 10.1016/j.ejso.2004.08.003

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  26 in total

1.  A Randomized Trial Comparing the Efficacy of Methylene Blue Dye Alone Versus Combination of Methylene Blue Dye and Radioactive Sulfur Colloid in Sentinel Lymph Node Biopsy for Early Stage Breast Cancer Patients.

Authors:  Vikas Gupta; Kvvn Raju; T Subramanyeshwar Rao; C K Naidu; Vipin Goel; Nisha Hariharan; Ramachandra Nagarajuch; B Madhunarayana
Journal:  Indian J Surg Oncol       Date:  2019-12-10

2.  Developing countries: an evolving opportunity for oncologic research.

Authors:  Rajendra A Badwe; Anil K D'cruz; Rajesh C Mistry; Hemant B Tongaonkar; Surendra Shastri; Mangesh A Thorat
Journal:  World J Surg       Date:  2006-07       Impact factor: 3.352

3.  A new optical probe for the detection of the sentinel lymph node using patent blue V dye in breast cancer: A preliminary study.

Authors:  F Tellier; P Poulet; J P Ghnassia; M Wilt; D Weitbruch; J F Rodier
Journal:  Mol Clin Oncol       Date:  2012-09-20

4.  Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience.

Authors:  Fatih Aydoğan; Akif Enes Arıkan; Erman Aytaç; Mehmet Velidedeoğlu; Mehmet Halit Yılmaz; Muhammet Sait Sager; Varol Çelik; Cihan Uras
Journal:  Ulus Cerrahi Derg       Date:  2015-08-18

5.  Clinicopathologic factors associated with false-negative sentinel lymph-node biopsy in breast cancer.

Authors:  Robert C G Martin; Anees Chagpar; Charles R Scoggins; Michael J Edwards; Lee Hagendoorn; Arnold J Stromberg; Kelly M McMasters
Journal:  Ann Surg       Date:  2005-06       Impact factor: 12.969

6.  Breast Cancer Sentinel Node Detection: An Alternative Solution for Centers Lacking Nuclear Technology.

Authors:  Mahmoud A Alhussini; Ahmed T Awad; Mohamed H Ashour; Ahmed Abdelateef; Haytham Fayed
Journal:  Breast Care (Basel)       Date:  2016-08-15       Impact factor: 2.860

7.  In vivo imaging of sentinel nodes using fluorescent silica nanoparticles in living mice.

Authors:  Yong Hyun Jeon; Young-Hwa Kim; Kihwan Choi; Jing Yu Piao; Bo Quan; Yun-Sang Lee; Jae Min Jeong; June-Key Chung; Dong Soo Lee; Myung Chul Lee; Jaetae Lee; Doo Soo Chung; Keon Wook Kang
Journal:  Mol Imaging Biol       Date:  2009-10-15       Impact factor: 3.488

8.  Staging the axilla with selective sentinel node biopsy in patients with previous excision of non-palpable and palpable breast cancer.

Authors:  R Ruano; M Ramos; J R Garcia-Talavera; E Serrano; A De Arriba; J Gonzalez-Orus; M Iglesias; M C Macias
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-02-12       Impact factor: 9.236

9.  A dual-modal magnetic nanoparticle probe for preoperative and intraoperative mapping of sentinel lymph nodes by magnetic resonance and near infrared fluorescence imaging.

Authors:  Zhengyang Zhou; Hongwei Chen; Malgorzata Lipowska; Liya Wang; Qiqi Yu; Xiaofeng Yang; Diana Tiwari; Lily Yang; Hui Mao
Journal:  J Biomater Appl       Date:  2013-07       Impact factor: 2.646

10.  The false-negative rate of sentinel node biopsy in patients with breast cancer: a meta-analysis.

Authors:  Sarah Pesek; Taka Ashikaga; Lars Erik Krag; David Krag
Journal:  World J Surg       Date:  2012-09       Impact factor: 3.352