| Literature DB >> 35111518 |
Masahiro Yoshida1, Koji Sato1, Tomohiro Ando1, Masatoshi Haruta1, Hiroaki Iwase1.
Abstract
OBJECTIVES: A majority of older adult acetabular fracture patients have a fracture of the anterior component, and repair of the acetabular anterior component with infra-acetabular screw (IAS) fixation is crucial. The aim of this study was to clarify the sex-specific differences in the secure infra-acetabular corridor for safe IAS placement.Entities:
Keywords: Acetabular fracture; Corridor angle; Corridor length; Infra-acetabular corridor; Infra-acetabular screw
Year: 2020 PMID: 35111518 PMCID: PMC8766652 DOI: 10.20407/fmj.2019-014
Source DB: PubMed Journal: Fujita Med J ISSN: 2189-7247
Figure 1X-ray of the infra-acetabular screw. (a) AP view, (b) obturator-oblique view and (c) 3D-CT of the postoperative X-ray of the infra-acetabular screw (IAS) used in the case of an acetabular fracture. Arrowheads: IAS
Characteristics of pelvis specimens
| Total (n=100) | Male (n=50) | Female (n=50) | Significance | |
|---|---|---|---|---|
| Age (years) | 77.5±9.6 (60–93) | 77.0±10.7 (61–92) | 77.8±8.4 (60–93) | NS |
| Diagnosis of affected side | ||||
| HF | 63 | 33 | 30 | NS |
| OA | 28 | 11 | 17 | |
| ON | 9 | 6 | 3 | |
NS=not significant, HF=hip fracture, OA=osteoarthritis, ON=osteonecrosis
Figure 2Axis of functional pelvic plane.
Red circle: Origin point=midpoint of the anterior superior iliac spine (ASIS).
Red arrow: X axis=ASIS digitize point line.
Blue arrow: Z axis=parallel to bed and perpendicular to X axis.
Green arrow: Y axis=perpendicular to X and Z axis
Figure 3Parameters measured using the ZedHip system. (a) acetabular size. (b) corridor length. Angle between the arrow and Y axis (green line) is the corridor angle in the axial plane (c) and in the sagittal plane (d). Corridor diameter is the distance between the white arrow heads (e).
Parameters of infraacetublum corridor
| Total (n=100) | Male (n=50) | Female (n=50) | Significance | |
|---|---|---|---|---|
| Acetabular size (mm) | 50.3±3.3 | 52.3±2.5 | 48.3±2.8 | p<0.01 |
| Corridor length (mm) | 95.3±6.2 | 99.0±4.6 | 91.5±5.3 | p<0.01 |
| Corridor angle (°) | ||||
| – axial plane | 6.8±5.4 | 5.1±4.9 | 8.6±5.3 | p<0.01 |
| – sagittal plane | 34.0±8.9 | 34.8±8.4 | 33.2±9.3 | NS |
| Minimum corridor diameter (mm) | 3.5±1.2 | 3.7±1.3 | 3.4±1.1 | NS |
| – Cases under 3.5 mm | 55 | 26 | 29 | NS |
| – Cases unable to place IAS | 32 | 15 | 17 | NS |
Figure 4Appropriate IAS direction in the axial plane for female (red arrow) and for male (blue arrow). Green arrow: Y axis.