Thermal Model of an Omnimagnet for Performance Assessment and Temperature Control.

Fateme Esmailie1, Matthew S Cavilla1, Jake J Abbott1, Tim A Ameel1.   

Abstract

An Omnimagnet is an electromagnetic device that enables remote magnetic manipulation of devices such as medical implants and microrobots. It is composed of three orthogonal nested solenoids with a ferromagnetic core at the center. Electrical current within the solenoids leads to undesired temperature increase within the Omnimagnet. If the temperature exceeds the melting point of the wire insulation, device failure may occur. Thus, a study of heat transfer within an Omnimagnet is a necessity, particularly to maximize the performance of the device. A transient heat transfer model that incorporates all three heat transfer modes is proposed and experimentally validated with an average normalized root-mean-square error of less than 4% (data normalized by temperature in degree celsius). The transient model is not computationally expensive and is applicable to Omnimagnets with different structures. The code is applied to calculate the maximum safe operational time at a fixed input current or the maximum safe input current for a fixed time interval. The maximum safe operational time and maximum safe input current depend on size and structure of the Omnimagnet and the lowest critical temperature of all the Omnimagnet materials. A parametric study shows that increasing convective heat transfer during cooling, and during heating with low input currents, is an effective method to increase the maximum operational time of the Omnimagnet. The thermal model is also presented in a state-space equation format that can be used in a real-time Kalman filter current controller to avoid device failure due to excessive heating.

Entities:  

Keywords:  Omnimagnet; lumped capacitance; optimization; state-space; thermal management; transient

Year:  2021        PMID: 35075383      PMCID: PMC8598201          DOI: 10.1115/1.4049869

Source DB:  PubMed          Journal:  J Therm Sci Eng Appl        ISSN: 1948-5085            Impact factor:   1.470


  2 in total

1.  Optimizing the Magnetic Dipole-Field Source for Magnetically Guided Cochlear-Implant Electrode-Array Insertions.

Authors:  Lisandro Leon; Frank M Warren; Jake J Abbott
Journal:  J Med Robot Res       Date:  2018-01-22

2.  An In-Vitro Insertion-Force Study of Magnetically Guided Lateral-Wall Cochlear-Implant Electrode Arrays.

Authors:  Lisandro Leon; Frank M Warren; Jake J Abbott
Journal:  Otol Neurotol       Date:  2018-02       Impact factor: 2.311

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.