Literature DB >> 35059540

Quadruple, 4-segment, triple sector "Y-shaped stents" in complex hilar cholangiocarcinoma after cholangitis from plastic stents.

Mohamed A Abdallah1, Martin L Freeman1, Stuart K Amateau1, Matthew R Krafft1.   

Abstract

Video 1Video showing successful placement of 4 uncovered self-expanding metal stents in a stent-in-stent, Y-shaped configuration for cholangitis from plastic stents in a patient with unresectable cholangiocarcinoma.
© 2022 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc.

Entities:  

Keywords:  LL-II, left lateral segment II; LL-III, left lateral segment III; RA, right anterior sectoral duct; RP, right posterior sectoral duct; SEMS, self-expanding metal stent

Year:  2021        PMID: 35059540      PMCID: PMC8755479          DOI: 10.1016/j.vgie.2021.09.009

Source DB:  PubMed          Journal:  VideoGIE        ISSN: 2468-4481


A 70-year-old Asian-American woman with a history of unresectable, locally advanced Bismuth-Corlette classification type IV perihilar cholangiocarcinoma initially presented with ascending cholangitis. Four weeks before presentation to our institution, the patient underwent percutaneous transhepatic biliary drainage at an outside hospital for biliary drainage after index ERCP failed to access the left and right intrahepatic bile ducts. One week after that, the patient presented to our institution with ascending cholangitis. ERCP was performed, revealing diffuse cholangitis. Salvage therapy included placement of 4 transpapillary biliary plastic stents into the right posterior sectoral duct (RP), right anterior sectoral duct (RA), left lateral segment II (LL-II), and left lateral segment III (LL-III). Evaluation by medical and surgical oncology recommended against surgical resection and palliative chemotherapy owing to the patient’s poor performance status. Therefore, the patient was referred for palliative endoscopic biliary drainage with an uncovered, laser-cut, nonforeshortening 6F delivery system, metallic stents. MRCP was not performed before the planned ERCP because the decision was made to drain all accessible liver sectors owing to the presence of cholangitis. A duodenoscope (TJF-Q180B; Olympus America, Center Valley, Pa, USA) was advanced to the second portion of the duodenum. The 4 previously placed transpapillary biliary plastic stents were removed using a snare (Fig. 1). The common bile duct was cannulated using a bending cannula (SwingTip; Olympus America). Cholangiogram showed typical biliary confluence anatomy with a Bismuth type IV perihilar tumor and diffuse intrahepatic biliary ductal dilation (Fig. 2). A total of four 0.025-inch × 450-cm straight guidewires (Visiglide; Olympus America) were passed into each of the 4 segmental intrahepatic ducts from which the 4 plastic stents were just removed (ie, RP, RA, LL-II, and LL-III) (Fig. 3). The confluence (takeoff) of each sectoral branch duct was dilated to 6 mm using a biliary balloon dilatation catheter (Hurricane RX; Boston Scientific; Marlborough, Mass, USA). Each of the 4 sectoral ducts was swept with a 9-mm retrieval balloon catheter (Extractor pro RX-S, Boston Scientific) to clear residual sludge and pus from each duct.
Figure 1

A, Fluoroscopic image showing 4 transpapillary biliary stents in the right posterior sectoral duct, right anterior sectoral duct, left lateral segment II, and left lateral segment III. B, Endoscopic image showing removal of the plastic stents before self-expanding metal stent insertion. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III.

Figure 2

Fluoroscopic image showing Bismuth-Corlette type IV perihilar cholangiocarcinoma and diffuse intrahepatic biliary ductal dilation.

Figure 3

A, Endoscopic and (B) fluoroscopic image showing four 0.025-inch × 450-cm straight Visiglide guidewires in each of the 4 segmental intrahepatic ducts. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III.

A, Fluoroscopic image showing 4 transpapillary biliary stents in the right posterior sectoral duct, right anterior sectoral duct, left lateral segment II, and left lateral segment III. B, Endoscopic image showing removal of the plastic stents before self-expanding metal stent insertion. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III. Fluoroscopic image showing Bismuth-Corlette type IV perihilar cholangiocarcinoma and diffuse intrahepatic biliary ductal dilation. A, Endoscopic and (B) fluoroscopic image showing four 0.025-inch × 450-cm straight Visiglide guidewires in each of the 4 segmental intrahepatic ducts. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III. Under fluoroscopic guidance, an intraductal 10-mm × 8-cm uncovered self-expanding metal stent (SEMS) (Zilver 635, Cook Medical, Bloomington, Ind, USA) was deployed across the hilum, spanning from the common hepatic duct into LL-III. The LL-III uncovered SEMS was cannulated over the wire using the SwingTip cannula. The guidewire was poked through a slit in the LL-III SEMS, passing into LL-II. A 10-mm × 6-cm uncovered Zilver 635 SEMS was advanced over the wire, passing through the slit in LL-III SEMS and into LL-II, forming a Y-shaped intraductal stent-in-stent (Fig. 4). The distal tip of the second SEMS (LL-II) was intentionally deployed proximal to the biliary bifurcation, so as not to impede creation of more Y-shaped intraductal stent-in-stent configurations in the right lobe of the liver.
Figure 4

Fluoroscopic image showing an intraductal 10-mm × 6-cm uncovered self-expanding metal stent that was advanced over the wire, passing through a slit in the left lateral segment III self-expanding metal stent and into the left lateral segment II, forming a Y-shaped intraductal stent-in-stent. LL-II, Left lateral segment II; LL-III, left lateral segment III.

Fluoroscopic image showing an intraductal 10-mm × 6-cm uncovered self-expanding metal stent that was advanced over the wire, passing through a slit in the left lateral segment III self-expanding metal stent and into the left lateral segment II, forming a Y-shaped intraductal stent-in-stent. LL-II, Left lateral segment II; LL-III, left lateral segment III. After creation of the first Y-shaped stent-in-stent in LL-II/III, we turned our attention to the obstructed RA and RP. The LL-III SEMS was recannulated using the SwingTip cannula; a guidewire was advanced through a slit in the SEMS, passing into the RP. A 10-mm × 8-cm uncovered Zilver 635 SEMS was deployed through the slit in the LL-III SEMS, terminating in the RP, forming a second Y-shaped intraductal stent-in-stent (Fig. 5). The process was again repeated such that the RA was drained via passage of a 10-mm × 8-cm uncovered Zilver 635 SEMS through the LL-III SEMS, forming a third Y-shaped intraductal stent-in-stent (Fig. 6).
Figure 5

Fluoroscopic image showing an intraductal 10-mm × 8-cm uncovered self-expanding metal stent that was deployed through a slit in the left lateral segment III self-expanding metal stent, terminating in the right posterior sectoral duct, forming a second Y-shaped intraductal stent-in-stent. RP, Right posterior; LL-II, left lateral segment II; LL-III, left lateral segment III.

Figure 6

Fluoroscopic image showing an intraductal 10-mm × 8-cm uncovered self-expanding metal stent that was deployed through a slit in the left lateral segment III self-expanding metal stent, terminating in the right anterior sectoral duct, forming a third Y-shaped intraductal stent-in-stent. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III.

Fluoroscopic image showing an intraductal 10-mm × 8-cm uncovered self-expanding metal stent that was deployed through a slit in the left lateral segment III self-expanding metal stent, terminating in the right posterior sectoral duct, forming a second Y-shaped intraductal stent-in-stent. RP, Right posterior; LL-II, left lateral segment II; LL-III, left lateral segment III. Fluoroscopic image showing an intraductal 10-mm × 8-cm uncovered self-expanding metal stent that was deployed through a slit in the left lateral segment III self-expanding metal stent, terminating in the right anterior sectoral duct, forming a third Y-shaped intraductal stent-in-stent. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III. The final stent configuration consisted of the initial SEMS extending from the common hepatic duct to LL-III, with 3 penetrating/traversing SEMSs terminating in LL-II, RP, and RA (Fig. 7). Four-week follow-up revealed normalization of total bilirubin, alanine transaminase, and aspartate transaminase and a significant decrease in alkaline phosphatase levels without cholangitis, with CT showing stable SEMS position (Fig. 8). The patient elected not to pursue further therapy and transitioned to home hospice care.
Figure 7

Fluoroscopic image showing the initial uncovered self-expanding metal stent extending from the common hepatic duct to the left lateral segment III, with 3 penetrating/traversing self-expanding metal stents terminating in the left lateral segment II, right posterior sectoral duct, and right anterior sectoral duct. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III.

Figure 8

CT obtained 4 weeks after insertion of uncovered self-expanding metal stents (SEMSs). A, Scout image showing the 4 previously placed SEMSs: 1 extending from the common hepatic duct to the left lateral segment III (LL-III), with 3 penetrating/traversing SEMSs terminating in left lateral segment II (LL-II), right posterior sectoral duct (RP), and right anterior sectoral duct (RA). B, Coronal view showing SEMS to LL-III with SEMS take-off to RP. C, Cross-sectional view showing SEMS to RA and RP. D, Cross-sectional view showing SEMS to LL-II, L-III, and RA.

Fluoroscopic image showing the initial uncovered self-expanding metal stent extending from the common hepatic duct to the left lateral segment III, with 3 penetrating/traversing self-expanding metal stents terminating in the left lateral segment II, right posterior sectoral duct, and right anterior sectoral duct. RP, Right posterior; RA, right anterior; LL-II, left lateral segment II; LL-III, left lateral segment III. CT obtained 4 weeks after insertion of uncovered self-expanding metal stents (SEMSs). A, Scout image showing the 4 previously placed SEMSs: 1 extending from the common hepatic duct to the left lateral segment III (LL-III), with 3 penetrating/traversing SEMSs terminating in left lateral segment II (LL-II), right posterior sectoral duct (RP), and right anterior sectoral duct (RA). B, Coronal view showing SEMS to LL-III with SEMS take-off to RP. C, Cross-sectional view showing SEMS to RA and RP. D, Cross-sectional view showing SEMS to LL-II, L-III, and RA. Most patients with perihilar cholangiocarcinoma present with unresectable disease, and endoscopic drainage provides an optimal therapeutic modality for biliary obstruction and cholangitis., In this setting, SEMSs are associated with higher technical success, fewer adverse events, and better survival compared with plastic stents., In this case, we expanded upon the Y-shaped intraductal stent-in-stent technique, successfully completing a triple Y-shaped configuration. All biliary sectoral branches that previously housed plastic stents were exchanged for SEMSs to prevent future episodes of cholangitis from occurring in the previously instrumented sectors. All 4 ducts were cannulated with a guidewire, facilitated by using a steerable catheter (Swingtip) before the deployment of any SEMS to guide insertion of subsequent SEMSs. All SEMSs were inserted suprapapillary because suprapapillary placement is associated with longer stent patency, lower risk of cholangitis (from presumed enteric-biliary reflux), and decreased risk of pancreatitis (from pancreatic duct orifice compression), compared with transpapillary SEMS insertion. The performance of the stent-in-stent versus side-by-side technique for biliary drainage in a meta-analysis of 4 studies (N = 158) was similar with respect to rates of successful placement, successful drainage, early adverse events, late adverse events, and stent occlusions. We elected to use the stent-in-stent technique to avoid potential stent overcrowding and compression of stents by one another. In addition, in our patient, the stent-in-stent technique was selected over side-by-side stents to facilitate endoscopic reintervention, including intraductal radiofrequency ablation of tumor ingrowth.7, 8, 9 Use of SEMSs for biliary stent placement is complex and needs to be performed by providers with expertise and experience in the management of malignant hilar biliary obstruction. Adverse events of SEMS insertion can be seen in up to 30% of patients and can include inappropriate placement in a resectable lesion, cholangitis secondary to placement in the wrong segmental ducts, tumor ingrowth, reactive hyperplasia, stone formation, and bleeding from SEMS erosion into vessels (Video 1, available online at www.giejournal.org).

Disclosure

Dr Amateau serves as a consultant for Boston scientific, Merit Endoscopy, US Endoscopy/Steris, a consultant and advisor for Olympus, and a consultant and research support for Cook Medical. All other authors disclosed no financial relationships.
  7 in total

1.  Efficacy of metal and plastic stents in unresectable complex hilar cholangiocarcinoma: a randomized controlled trial.

Authors:  Apichat Sangchan; Worrarat Kongkasame; Ake Pugkhem; Kriangsak Jenwitheesuk; Pisaln Mairiang
Journal:  Gastrointest Endosc       Date:  2012-05-15       Impact factor: 9.427

Review 2.  Endoscopic radiofrequency ablation for cholangiocarcinoma.

Authors:  Christopher A Wadsworth; David Westaby; Shahid A Khan
Journal:  Curr Opin Gastroenterol       Date:  2013-05       Impact factor: 3.287

3.  Comparison of uncovered stent placement across versus above the main duodenal papilla for malignant biliary obstruction.

Authors:  Xianchen Huang; Liming Shen; Yiqi Jin; Lei Chen; Dayong Zhou; Guoxiong Xu; Caifang Ni
Journal:  J Vasc Interv Radiol       Date:  2015-01-13       Impact factor: 3.464

Review 4.  Cholangiocarcinoma.

Authors:  Nataliya Razumilava; Gregory J Gores
Journal:  Lancet       Date:  2014-02-26       Impact factor: 79.321

5.  Plastic versus self-expanding metallic stents for malignant hilar biliary obstruction: a prospective multicenter observational cohort study.

Authors:  David G Perdue; Martin L Freeman; James A DiSario; Douglas B Nelson; M Brian Fennerty; John G Lee; Carol S Overby; Michael E Ryan; Gary S Bochna; Harry W Snady; Joseph P Moore
Journal:  J Clin Gastroenterol       Date:  2008-10       Impact factor: 3.062

Review 6.  Bilateral stenting methods for hilar biliary obstructions.

Authors:  Wandong Hong; Shanxi Chen; Qihuai Zhu; Huichun Chen; Jingye Pan; Qingke Huang
Journal:  Clinics (Sao Paulo)       Date:  2014-09       Impact factor: 2.365

7.  Endoscopic Drainage of >50% of Liver in Malignant Hilar Biliary Obstruction Using Metallic or Fenestrated Plastic Stents.

Authors:  Tossapol Kerdsirichairat; Mustafa A Arain; Rajeev Attam; Brooke Glessing; Yan Bakman; Stuart K Amateau; Martin L Freeman
Journal:  Clin Transl Gastroenterol       Date:  2017-08-31       Impact factor: 4.488

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.