Literature DB >> 25595724

Comparison of uncovered stent placement across versus above the main duodenal papilla for malignant biliary obstruction.

Xianchen Huang1, Liming Shen1, Yiqi Jin1, Lei Chen1, Dayong Zhou1, Guoxiong Xu1, Caifang Ni2.   

Abstract

PURPOSE: To evaluate the differences in efficiency and complications of metal stent insertion across versus above the main duodenal papilla (MDP) in patients with malignant obstruction of the common bile duct (CBD).
MATERIALS AND METHODS: Records of 98 consecutive patients who underwent stent insertion for malignant CBD obstruction between 2004 and 2010 were retrospectively reviewed. Fifty-one patients (group 1) and 47 patients (group 2) were treated with stent insertion across and above the MDP, respectively. Primary stent patency, overall survival, complications, and changes in serum bilirubin level following stent insertion were assessed.
RESULTS: Infection appeared in 12 and four patients, respectively, in groups 1 and 2. The respective mean primary stent patency times were 307.8 days ± 20.2 and 490.7 days ± 40.7, and mean survival times were 245.1 days ± 17.4 and 286.3 days ± 20.2. Bilirubin reduction rates were 55.7% ± 16.6 and 61.1% ± 13.7 at 1 week and 84.2% ± 5.7 and 86.2% ± 5.7 at 1 month in groups 1 and 2, respectively. In group 2, the rate of infection was significantly lower (P = .044) and primary stent patency was longer (P = .019). However, there was no significant difference between groups in survival time (P = .074) or bilirubin reduction rate at 1 week (P = .083) or 1 month (P = .082).
CONCLUSIONS: Bile stent insertion above the MDP may achieve longer stent patency and a lower infection rate compared with placement across the MDP. For patients with malignant CBD obstruction, biliary stents should be placed above the papilla if papillary lesions are not invaded.
Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25595724     DOI: 10.1016/j.jvir.2014.11.008

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  6 in total

Review 1.  Biliary Interventions: Tools and Techniques of the Trade, Access, Cholangiography, Biopsy, Cholangioscopy, Cholangioplasty, Stenting, Stone Extraction, and Brachytherapy.

Authors:  Osman Ahmed; Sipan Mathevosian; Bulent Arslan
Journal:  Semin Intervent Radiol       Date:  2016-12       Impact factor: 1.513

2.  Percutaneous transpapillary biliary stent placement for distal malignant biliary obstruction: Outcomes and survival analysis.

Authors:  Qing-Quan Zu; Jin-Xing Zhang; Bin Wang; Wei Ye; Sheng Liu; Hai-Bin Shi
Journal:  Turk J Gastroenterol       Date:  2019-08       Impact factor: 1.852

3.  Self-expandable metallic stent placement above the papilla without endoscopic sphincterotomy in patients with distal malignant biliary obstruction.

Authors:  Ryoji Takada; Kenji Ikezawa; Ryosuke Kiyota; Toshihiro Imai; Yutaro Abe; Nobuyasu Fukutake; Reiko Ashida; Takatoshi Nawa; Takahiro Tabuchi; Kazuhiro Katayama; Kazuyoshi Ohkawa
Journal:  Endosc Int Open       Date:  2020-05-25

4.  Endoscopic Drainage of >50% of Liver in Malignant Hilar Biliary Obstruction Using Metallic or Fenestrated Plastic Stents.

Authors:  Tossapol Kerdsirichairat; Mustafa A Arain; Rajeev Attam; Brooke Glessing; Yan Bakman; Stuart K Amateau; Martin L Freeman
Journal:  Clin Transl Gastroenterol       Date:  2017-08-31       Impact factor: 4.488

5.  Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction.

Authors:  Jin-Xing Zhang; Qing-Quan Zu; Sheng Liu; Chun-Gao Zhou; Jin-Guo Xia; Hai-Bin Shi
Journal:  Saudi J Gastroenterol       Date:  2018 Mar-Apr       Impact factor: 2.485

6.  Quadruple, 4-segment, triple sector "Y-shaped stents" in complex hilar cholangiocarcinoma after cholangitis from plastic stents.

Authors:  Mohamed A Abdallah; Martin L Freeman; Stuart K Amateau; Matthew R Krafft
Journal:  VideoGIE       Date:  2021-12-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.