Literature DB >> 3505303

Turbulence downstream from the Ionescu-Shiley bioprosthesis in steady and pulsatile flow.

D D Hanle, E C Harrison, A P Yoganathan, W H Corcoran.   

Abstract

Mesh:

Year:  1987        PMID: 3505303     DOI: 10.1007/bf02447332

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  22 in total

1.  Deformation and fragmentation of human red blood cells in turbulent shear flow.

Authors:  S P Sutera; M H Mehrjardi
Journal:  Biophys J       Date:  1975-01       Impact factor: 4.033

2.  The response of human platelets to shear stress at short exposure times.

Authors:  G Colantuoni; J D Hellums; J L Moake; C P Alfrey
Journal:  Trans Am Soc Artif Intern Organs       Date:  1977

3.  Hemolysis and subhemolytic alterations of human RBC induced by turbulent shear flow.

Authors:  S P Sutera; P A Croce; M Mehrjardi
Journal:  Trans Am Soc Artif Intern Organs       Date:  1972

4.  Red blood cell damage by shear stress.

Authors:  L B Leverett; J D Hellums; C P Alfrey; E C Lynch
Journal:  Biophys J       Date:  1972-03       Impact factor: 4.033

5.  In vitro velocity measurements down stream from the Ionescu-Shiley aortic bioprosthesis in steady and pulsatile flow.

Authors:  D D Hanle; E C Harrison; A P Yoganathan; W H Corcoran
Journal:  Med Biol Eng Comput       Date:  1986-09       Impact factor: 2.602

6.  In vitro fluid dynamic characteristics of Ionescu-Shiley and Carpentier-Edwards tissue bioprostheses.

Authors:  A P Yoganathan; Y R Woo; F P Williams; D M Stevenson; R H Franch; E C Harrison
Journal:  Artif Organs       Date:  1983-11       Impact factor: 3.094

7.  Fresh human aortic and artificial heart valves studied in vitro using ultramicroscope anemometry. Further results.

Authors:  D Schramm; H Müller-Mohnssen; W Baldauf; H Meisner
Journal:  Thorac Cardiovasc Surg       Date:  1982-10       Impact factor: 1.827

8.  Morphological, biochemical, and functional changes in human platelets subjected to shear stress.

Authors:  C H Brown; L B Leverett; C W Lewis; C P Alfrey; J D Hellums
Journal:  J Lab Clin Med       Date:  1975-09

9.  Heart valve replacement with the Ionescu-Shiley pericardial xenograft.

Authors:  M I Ionescu; A P Tandon; D A Mary; A Abid
Journal:  J Thorac Cardiovasc Surg       Date:  1977-01       Impact factor: 5.209

10.  Hemolysis near an ultrasonically pulsating gas bubble.

Authors:  J A Rooney
Journal:  Science       Date:  1970-08-28       Impact factor: 47.728

View more
  4 in total

1.  In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve.

Authors:  Megan Heitkemper; Hoda Hatoum; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2019-06-19

Review 2.  A relationship between Reynolds stresses and viscous dissipation: implications to red cell damage.

Authors:  S A Jones
Journal:  Ann Biomed Eng       Date:  1995 Jan-Feb       Impact factor: 3.934

3.  Stented valve dynamic behavior induced by polyester fiber leaflet material in transcatheter aortic valve devices.

Authors:  Hoda Hatoum; Frederick Heim; Lakshmi Prasad Dasi
Journal:  J Mech Behav Biomed Mater       Date:  2018-06-28

4.  An in vitro evaluation of turbulence after transcatheter aortic valve implantation.

Authors:  Hoda Hatoum; Atieh Yousefi; Scott Lilly; Pablo Maureira; Juan Crestanello; Lakshmi P Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-02       Impact factor: 5.209

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.