Literature DB >> 35042385

A multi-modality approach for enhancing 4D flow magnetic resonance imaging via sparse representation.

Jiacheng Zhang1, Melissa C Brindise1, Sean M Rothenberger2, Michael Markl3,4, Vitaliy L Rayz1,2, Pavlos P Vlachos1,2.   

Abstract

This work evaluates and applies a multi-modality approach to enhance blood flow measurements and haemodynamic analysis with phase-contrast magnetic resonance imaging (4D flow MRI) in cerebral aneurysms (CAs). Using a library of high-resolution velocity fields from patient-specific computational fluid dynamic simulations and in vitro particle tracking velocimetry measurements, the flow field of 4D flow MRI data is reconstructed as the sparse representation of the library. The method was evaluated with synthetic 4D flow MRI data in two CAs. The reconstruction enhanced the spatial resolution and velocity accuracy of the synthetic MRI data, leading to reliable pressure and wall shear stress (WSS) evaluation. The method was applied on in vivo 4D flow MRI data acquired in the same CAs. The reconstruction increased the velocity and WSS by 6-13% and 39-61%, respectively, suggesting that the accuracy of these quantities was improved since the raw MRI data underestimated the velocity and WSS by 10-20% and 40-50%, respectively. The computed pressure fields from the reconstructed data were consistent with the observed flow structures. The results suggest that using the sparse representation flow reconstruction with in vivo 4D flow MRI enhances blood flow measurement and haemodynamic analysis.

Entities:  

Keywords:  4D flow MRI; cerebral aneurysm; data fusion; haemodynamic evaluation; sparse representation

Mesh:

Year:  2022        PMID: 35042385      PMCID: PMC8767185          DOI: 10.1098/rsif.2021.0751

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.293


  34 in total

1.  Accelerated dual-venc 4D flow MRI for neurovascular applications.

Authors:  Susanne Schnell; Sameer A Ansari; Can Wu; Julio Garcia; Ian G Murphy; Ozair A Rahman; Amir A Rahsepar; Maria Aristova; Jeremy D Collins; James C Carr; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

2.  Identification of vortex structures in a cohort of 204 intracranial aneurysms.

Authors:  Nicole Varble; Gabriel Trylesinski; Jianping Xiang; Kenneth Snyder; Hui Meng
Journal:  J R Soc Interface       Date:  2017-05       Impact factor: 4.118

Review 3.  Prevalence of unruptured intracranial aneurysms, with emphasis on sex, age, comorbidity, country, and time period: a systematic review and meta-analysis.

Authors:  Monique Hm Vlak; Ale Algra; Raya Brandenburg; Gabriël Je Rinkel
Journal:  Lancet Neurol       Date:  2011-07       Impact factor: 44.182

4.  Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio.

Authors:  A T Lee; G B Pike; N J Pelc
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

5.  Prevalence and risk of rupture of intracranial aneurysms: a systematic review.

Authors:  G J Rinkel; M Djibuti; A Algra; J van Gijn
Journal:  Stroke       Date:  1998-01       Impact factor: 7.914

6.  Regularization Paths for Generalized Linear Models via Coordinate Descent.

Authors:  Jerome Friedman; Trevor Hastie; Rob Tibshirani
Journal:  J Stat Softw       Date:  2010       Impact factor: 6.440

7.  Wall shear stress on ruptured and unruptured intracranial aneurysms at the internal carotid artery.

Authors:  L-D Jou; D H Lee; H Morsi; M E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2008-07-03       Impact factor: 3.825

8.  PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models.

Authors:  Matthew D Ford; Hristo N Nikolov; Jaques S Milner; Stephen P Lownie; Edwin M Demont; Wojciech Kalata; Francis Loth; David W Holdsworth; David A Steinman
Journal:  J Biomech Eng       Date:  2008-04       Impact factor: 2.097

Review 9.  Guidelines for the surgical treatment of unruptured intracranial aneurysms: the first annual J. Lawrence pool memorial research symposium--controversies in the management of cerebral aneurysms.

Authors:  Ricardo J Komotar; J Mocco; Robert A Solomon
Journal:  Neurosurgery       Date:  2008-01       Impact factor: 4.654

10.  Density and Viscosity Matched Newtonian and non-Newtonian Blood-Analog Solutions with PDMS Refractive Index.

Authors:  Melissa C Brindise; Margaret M Busse; Pavlos P Vlachos
Journal:  Exp Fluids       Date:  2018-10-30       Impact factor: 2.480

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.