Radio-frequency coils in implantable devices: misalignment analysis and design procedure.

M Soma, D C Galbraith, R L White.   

Abstract

Mesh:

Year:  1987        PMID: 3504201     DOI: 10.1109/tbme.1987.326088

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


× No keyword cloud information.
  10 in total

1.  Class E driver for transcutaneous power and data link for implanted electronic devices.

Authors:  P R Troyk; M A Schwan
Journal:  Med Biol Eng Comput       Date:  1992-01       Impact factor: 2.602

2.  Telemetry system for monitoring anterior cruciate ligament graft forces in vivo.

Authors:  E L McKee; D P Lindsey; M L Hull; S M Howell
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

3.  Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

Authors:  Sung-Eun Jo; Sanghoon Joung; Jun-Kyo Francis Suh; Yong-Jun Kim
Journal:  Med Biol Eng Comput       Date:  2012-07-18       Impact factor: 2.602

4.  Geometrical Design of a Scalable Overlapping Planar Spiral Coil Array to Generate a Homogeneous Magnetic Field.

Authors:  Uei-Ming Jow; Maysam Ghovanloo
Journal:  IEEE Trans Magn       Date:  2012-12-21       Impact factor: 1.700

5.  Power Loss Analysis and Comparison of Segmented and Unsegmented Energy Coupling Coils for Wireless Energy Transfer.

Authors:  Sai Chun Tang; Nathan J McDannold
Journal:  IEEE J Emerg Sel Top Power Electron       Date:  2014-06-13       Impact factor: 4.472

6.  Swallowable wireless capsule endoscopy: progress and technical challenges.

Authors:  Guobing Pan; Litong Wang
Journal:  Gastroenterol Res Pract       Date:  2011-12-27       Impact factor: 2.260

7.  Analysis and optimization of spiral circular inductive coupling link for bio-implanted applications on air and within human tissue.

Authors:  Saad Mutashar; Mahammad A Hannan; Salina A Samad; Aini Hussain
Journal:  Sensors (Basel)       Date:  2014-06-30       Impact factor: 3.576

8.  Archimedean Spiral Pairs with no Electrical Connections as a Passive Wireless Implantable Sensor.

Authors:  John F Drazan; Aleksandra Gunko; Matthew Dion; Omar Abdoun; Nathaniel C Cady; Kenneth A Connor; Eric H Ledet
Journal:  J Biomed Technol Res       Date:  2014-08-18

9.  Co-Design Method and Wafer-Level Packaging Technique of Thin-Film Flexible Antenna and Silicon CMOS Rectifier Chips for Wireless-Powered Neural Interface Systems.

Authors:  Kenji Okabe; Horagodage Prabhath Jeewan; Shota Yamagiwa; Takeshi Kawano; Makoto Ishida; Ippei Akita
Journal:  Sensors (Basel)       Date:  2015-12-16       Impact factor: 3.576

10.  Miniaturized Self-Resonant Micro Coil Array with A Floating Structure for Wireless Multi-Channel Transmission.

Authors:  Byoung Ok Jun; Han-Joon Kim; Su Jin Heo; Jonghyeun Kim; Jae Hoon Yang; Seunguk Kim; Kyungtae Kim; Woo-Cheol Jin; Ji-Woong Choi; Jae Eun Jang
Journal:  Adv Sci (Weinh)       Date:  2021-10-29       Impact factor: 16.806