Literature DB >> 22806430

Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

Sung-Eun Jo1, Sanghoon Joung, Jun-Kyo Francis Suh, Yong-Jun Kim.   

Abstract

Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condition. It was confirmed that the CMC coil had higher transmission efficiency than typical air-core coil. The power transmission efficiency during a misalignment between primary coil and implanted secondary coil was also evaluated. The decrease of mutual inductance between the two coils caused by the misalignment led to a low efficiency of the inductive link. Therefore, it is important to properly align the primary coil and implanted secondary coil for effective power transmission. To align the coils, a feedback coil was proposed. This was integrated on the backside of the primary coil and enabled the detection of a misalignment of the primary and secondary coils. As a result of using the feedback coil, the primary and secondary coils could be aligned without knowledge of the position of the implanted secondary coil.

Entities:  

Mesh:

Year:  2012        PMID: 22806430     DOI: 10.1007/s11517-012-0939-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  An implantable device for stimulation of denervated muscles in rats.

Authors:  Robert G Dennis; Douglas E Dow; John A Faulkner
Journal:  Med Eng Phys       Date:  2003-04       Impact factor: 2.242

2.  In vivo robotic capsules: determination of the number of turns of its power receiving coil.

Authors:  Yong Up Lee; Jong Dae Kim; Munho Ryu; Jongwon Kim
Journal:  Med Biol Eng Comput       Date:  2006-11-10       Impact factor: 2.602

3.  A large-area wireless power-transmission sheet using printed organic transistors and plastic MEMS switches.

Authors:  Tsuyoshi Sekitani; Makoto Takamiya; Yoshiaki Noguchi; Shintaro Nakano; Yusaku Kato; Takayasu Sakurai; Takao Someya
Journal:  Nat Mater       Date:  2007-04-29       Impact factor: 43.841

4.  Three-dimensional power receiver for in vivo robotic capsules.

Authors:  Munho Ryu; Jong Dae Kim; Hyun Uk Chin; Jongwon Kim; Si Young Song
Journal:  Med Biol Eng Comput       Date:  2007-08-08       Impact factor: 2.602

5.  Feedback analysis and design of RF power links for low-power bionic systems.

Authors:  M W Baker; R Sarpeshkar
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2007-03       Impact factor: 3.833

6.  Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission.

Authors:  M Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2007-09       Impact factor: 3.833

Review 7.  Wireless and inductively powered implant for measuring electrocardiogram.

Authors:  Jarno Riistama; Juho Väisänen; Sami Heinisuo; Hanna Harjunpää; Satu Arra; Kati Kokko; Maunu Mäntylä; Jutta Kaihilahti; Pekka Heino; Minna Kellomäki; Outi Vainio; Jukka Vanhala; Jukka Lekkala; Jari Hyttinen
Journal:  Med Biol Eng Comput       Date:  2007-10-11       Impact factor: 2.602

8.  Radio-frequency coils in implantable devices: misalignment analysis and design procedure.

Authors:  M Soma; D C Galbraith; R L White
Journal:  IEEE Trans Biomed Eng       Date:  1987-04       Impact factor: 4.538

9.  A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation.

Authors:  Emil Jovanov; Aleksandar Milenkovic; Chris Otto; Piet C de Groen
Journal:  J Neuroeng Rehabil       Date:  2005-03-01       Impact factor: 4.262

  9 in total